Assessment of Cardiac Output in Patients With ARDS Implanted With Venous-venous ECMO.

Assessment of Cardiac Output by Transpulmonary Thermodilution and Pulse Contour Analysis in Patients With ARDS Implanted by Venous-venous ECMO

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05164484
Acronym
PiCCMO
Enrollment
20
Registered
2021-12-20
Start date
2021-01-19
Completion date
2025-01-15
Last updated
2022-11-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Respiratory Distress Syndrome

Keywords

ARDS, Venovenous Extracorporeal Membrane Oxygenation, Pulmonary Thermodilution, Cardiac Output

Brief summary

In patients with severe acute respiratory distress syndrome, extracorporeal membrane oxygenation (ECMO), which also as known as extracorporeal life support, may be used. This technique helps the lungs by providing oxygenation to the blood via an external gas exchanger and thus participates partially or fully in gas exchange. The ECMO device includes a pump for draining and returning blood at a certain blood flow rate (ECMO blood flow). An ECMO rate that is adapted to the patient's cardiac output (CO) is essential for effective oxygenation for patients. The objective for clinicians is an ECMO blood flow to cardiac output ≥40%, which can go up to 100% as needed. In addition to the expected benefit in the management of the patient with ARDS, measuring CO is, therefore, all the more important in patients requiring ECMO. Monitoring CO in a patient with ECMO is not only for determining the minimum ECMO blood flow rate but also for optimizing the functioning of the ECMO. However, the validity of techniques for measuring CO in patients with ECMO has been poorly studied. The reliability of the CO measurement by transpulmonary thermodilution is questioned since the extracorporeal circulation may influence the pathway of cold indicator injected into the patients' circulation and the thermodilution curve measured from the femoral arterial is thereby modified.

Detailed description

Acute respiratory distress syndrome (ARDS) is a severe and common condition with up to 45% mortality in ICU. Its respiratory management includes protective mechanical ventilation, the use of a positive end-expiratory pressure level, sometimes the performance of recruitment maneuvers or prone position, and the use of neuromuscular blockers. Due to heart-lung interactions, these different strategies can induce significant or even deleterious hemodynamic effects. Thus, hemodynamic monitoring in such patients is essential. It could assess the effect of ventilatory settings and optimize hemodynamic management. Optimization of arterial oxygen transport in hypoxemic patients may require an increase in the patient's cardiac output (CO). Fluid administration is one of the first-line strategies for achieving this objective. However, unnecessary fluid administration can lead to an increase in pulmonary edema and thus increase the duration of mechanical ventilation and hospitalization. Transpulmonary thermodilution is one of the advanced hemodynamic monitoring in ICU, which consists of the injection of three boluses of cold saline of 15 ml through a central venous catheter located in the superior vena cava, causing a drop in blood temperature which is detected by a femoral arterial catheter equipped with a thermistor. It was demonstrated to be a reliable and simple technique at the bedside for measuring CO. Combined with another technique, pulse contour analysis analysis, transpulmonary thermodilution allows to measure CO beat-to-beat. In addition, transpulmonary thermodilution can measure various hemodynamic variables of interest such as the global end-diastolic volume index (GEDVI, cardiac preload index), the cardiac function index (CFI, cardiac contractility index), extravascular lung water index (EVLWI, volume of fluid accumulated in the alveolar and interstitial lung sectors) and the pulmonary vascular permeability index (PVPI). The last two indices are particularly interesting in patients with ARDS, and were shown to be associated with mortality in patients with ARDS independently. In severe ARDS, ECMO may be another choice. This technique helps the lungs to rest by providing oxygenation to the blood via an external gas exchanger and thus participates partially or fully in gas exchange. The ECMO includes a central pump for draining and returning blood at a given blood flow rate (ECMO blood flow rate). The recommended oxygenation target for patients receiving venous-venous extracorporeal membrane oxygenation (VV-ECMO) assistance is when peripheral oxygen saturation (SpO2) is ≥80%. An ECMO blood flow rate adapted to the patient's CO is essential for effective extracorporeal oxygenation. The objective is an ECMO blood flow /CO ≥40%. It can also go up to 100% as needed (8). This rate can be modified by adjusting the central pump. Thus, it is obvious that measuring CO is important in patients requiring ECMO. However, the techniques measuring CO in patients with ECMO have been poorly studied. the reliability of the measurement of transpulmonary thermodilution was questioned since the analysis of the thermodilution curve can be modified by the extracorporeal circulation. This effect does not matter in a low flow extracorporeal deviation, such as that which is achieved for example during a continuous extrarenal purification . Some studies have shown that transpulmonary thermodilution measurements remain reliable when using another extracorporeal circuit, extracorporeal carbon dioxide removal, whose flow rate can go up to 2.4 L / min. It could be different from ECMO, the blood flow of which is higher. The only available study, conducted by Herner et al, demonstrated the reliability of measuring CO by transpulmonary thermodilution during ECMO. However, the ECMO blood flow/CO ratio was only around 40% in this study. For higher ECMO blood flow/CO ratio (\> 40%), the problem remains unresolved.

Interventions

Through the analysis of the thermodilution curve recorded at the tip of an arterial catheter after the injection of a cold bolus in the venous circulation, transpulmonary thermodilution intermittently measures cardiac output.

Sponsors

Assistance Publique - Hôpitaux de Paris
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* ≥18yrs. * With acute respiratory distress syndrome. * Monitored by transpulmonary thermodilution device. * Implanted by VV-ECMO. * Affiliated to the French Health Insurance

Exclusion criteria

* Pregnancy * Patient placed under judicial protection * Patient on state medical aid (AME, Aide Medicale d'Etat)

Design outcomes

Primary

MeasureTime frameDescription
The measurements of CO by transpulmonary thermodilution compared to CO measured by echocardiographyThe first week during patient is under ECMO assistanceStandard measurements by injection of three cold bolus in the venous circulation for transpulmonary thermodilution and standard echocardiography procedures.

Secondary

MeasureTime frameDescription
The CO measurements by pulse contour analyse at different ECMO blood flow/CO ratio.The first week during patient is under ECMO assistance
The changes of transpulmonary thermodilution parameter :GEDVI measured at different ECMO blood flow/CO ratio.The first week during patient is under ECMO assistanceGEDVI (Global end diastolic volume index) measured in mL/m\^2
The changes of transpulmonary thermodilution parameter : CFI measured at different ECMO blood flow/CO ratio.The first week during patient is under ECMO assistanceCFI (Cardiac function index) measured in 1/min
The changes of transpulmonary thermodilution parameters : EVLWI measured at different ECMO blood flow/CO ratio.The first week during patient is under ECMO assistanceEVLWI (Extravascular Lung Water index) measured in mL/kg
The changes of transpulmonary thermodilution parameter : PVPI (Pulmonary Vascular Permeability Index) measured at different ECMO blood flow/CO ratio.The first week during patient is under ECMO assistance

Countries

France

Contacts

Primary ContactChristopher LAI, M.D.
christopher.lai@aphp.fr33 (0)1 45 21 26 71
Backup ContactXavier MONNET, M.D., Ph.D.
xavier.monnet@aphp.fr33 (0)6 60 86 26 69

Outcome results

None listed