Skip to content

Clinical Evaluation of the Panbio™ COVID-19/ Flu A&B Rapid Panel

Clinical Evaluation of the Panbio™ COVID-19/ Flu A&B Rapid Panel

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05163730
Enrollment
2472
Registered
2021-12-20
Start date
2021-11-01
Completion date
2022-02-11
Last updated
2022-07-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

COVID-19, Influenza A, Influenza Type B

Brief summary

This study is designed as a prospective, multicentric, clinical study to investigate the performance of the Panbio™ COVID-19/ Flu A&B Rapid Panel for the qualitative detection of COVID-19 antigen, Influenza A antigen (H1N1 and H3N2), and Influenza B antigen in human nasal swabs. This study is part of the performance evaluation to support the CE conformity assessment procedures.

Detailed description

After obtaining written informed consent, a study-specific participant identification number (ID) will be assigned to the participant. Participant demographics and a brief medical history will be collected. One nasal swab sample will be collected from both nostrils by operators and will be used to perform the Panbio™ COVID-19/ Flu A&B Rapid Panel test either in a laboratory or in a non-laboratory setting (e.g. GP (general practitioner) centre or hospital clinic). Each Panbio™ COVID-19/ Flu A&B Rapid Panel result will be photographed by the observer at the time of test interpretation. Nasopharyngeal samples will be collected and used for RT-PCR (Reverse transcription polymerase chain reaction) testing as per local procedures. Nasal samples must always be collected prior to the Nasopharyngeal sampling. A minimum of 90 Flu A positive subjects, a minimum of 90 Flu B positive subjects and a minimum of 100 SARS-CoV-2 positive subjects will be enrolled. In addition, a minimum of 385 negative subjects will be enrolled. In total, a minimum of 665 male and female subjects will be prospectively enrolled at multiple clinical sites. Collection procedure will be a mid-turbinate nasal swab (deep nasal swab), by turning the swab five times in each nostril. Nasal samples must be collected prior to the Nasopharyngeal sampling. The collected swab will be tested with the Panbio™ COVID-19/ Flu A&B Rapid Panel at the study site. Tubes and swabs should be labelled with the patient ID. After the nasal sampling, study staff personnel will also collect one nasopharyngeal swab. The nasopharyngeal swab will be eluted in Universal Transport Media (UTM) and used for testing with RT-PCR protocols for Flu A, Flu B and SARS-CoV-2 as per local procedures. The RT-PCR methods used must have CE marking or FDA approval, with COVID-19 and Flu assay clearance for nasopharyngeal specimens. Nasopharyngeal sampling should be performed by trained healthcare professionals who routinely conduct nasopharyngeal sampling as part of their other standard of care and clinical duties. Each operator who performs a Panbio™ COVID-19/ Flu A&B Rapid Panel test will fill out a user evaluation questionnaire once, to assess the usability of the device. All other aspects of the Subject's care will remain the same with no deviation from prescribed practice.

Interventions

DEVICECOVID-19/ Flu A&B Rapid Panel

Rapid Diagnostic Device

Sponsors

Abbott Rapid Diagnostics Jena GmbH
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

* • Subjects from all age groups, able and willing to provide written informed consent or assent, suspected of having a respiratory viral infection consistent with COVID-19 and or Flu by their healthcare provider within the first seven days of the onset of symptoms, and presenting at least two of the following symptoms: fever, headache, extreme tiredness, dry cough, sore throat, runny or stuffy nose, muscle aches, loss of smell, loss of taste or shortness of breath, will be prospectively enrolled.

Exclusion criteria

* • Subject has had a nasal or a nasopharyngeal swab taken within the last 4 hours. * Subject has active nose bleeds or acute facial injuries/trauma * Subject has received a nasal vaccine (i.e., FluMist®) within the previous five (5) days. * Subject is currently taking or has taken an antiviral medication-i.e., Amantadine, Rimantadine, Relenza® (Zanamivir), Tamiflu® (Oseltamivir Phosphate), and Flumadine®-for influenza within the previous thirty (30) days. * Subject is currently enrolled in a study to evaluate an investigational drug. * Subject is unwilling or unable to provide informed consent. * Vulnerable populations as deemed inappropriate for study by the site's PI and/or reviewing REC (Research Ethics Committee).

Design outcomes

Primary

MeasureTime frameDescription
Sensitivity and Specificity8 monthsSensitivity of 70% is the target at the lower bound of the 95% confidence interval for SARS-CoV-2 and 70% for each Flu. The target specificity is 95% at the lower bound of the 95% confidence interval for each test line.

Secondary

MeasureTime frameDescription
Usability8 monthsThe secondary objective of this study is to assess the usability of the Panbio™ Rapid Panel, as collected by trained healthcare workers.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026