Flow Sensor and Colourimetric Capnometer in Verifying Tracheal Tube Positioning in Term and Preterm Infants

Comparison Between Flow Sensor and Colourimetric Capnometer in Verifying the Correct Positioning of the Endotracheal Tube in Term and Preterm Infants

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05162313
Acronym
FlowNET
Enrollment
105
Registered
2021-12-17
Start date
2022-02-10
Completion date
2023-06-30
Last updated
2022-03-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Tracheal Intubation

Keywords

tracheal intubation, tracheal tube positioning, colorimetric capnometer, flow sensor, invasive mechanical ventilation, newborn, preterm infant

Brief summary

This is a multicentre clinical trial with medical device. As currently recommended by international neonatal resuscitation guidelines, the most reliable method to verify the correct positioning of the endotracheal tube, in association with clinical signs, is the end-tidal capnometry obtained either by infrared spectroscopy or colorimetric method. The aim of the present study is to evaluate whether the flow sensor of a standard mechanical ventilator can discriminate with similar or faster times the correct positioning of the tube after a tracheal intubation attempt compared to the colorimetric capnometer, in newborns undergoing this procedure during hospitalization in the neonatal intensive care unit. Given the importance of defining a rapid and effective method to prevent possible adverse events of incorrect endotracheal intubation, this study aims to verify whether the ventilator flow sensor can allow a reliable assessment of the correct positioning of the endotracheal tube, with timing and success rates equivalent to or better than the colorimetric capnometer.

Detailed description

Specifically, the neonatologist performing the procedure will follow the standard procedure for tracheal intubation, which includes using a colourimetric capnometer to confirm the correct tube positioning. However, he/she will remain blind and not aware of the flow sensor signal, while a study investigator will monitor that. The investigators will measure the percentage of responses of correct positioning of the endotracheal tube as well as the number of insufflations and the time elapsed before obtaining a signal of correct intubation by simultaneously comparing both methods and checking any differences based on the characteristics of the sample analyzed (e.g. premature infants versus term infants, elective versus emergency intubations).

Interventions

DEVICEconfirmation of endotracheal tube positioning

After performing the tube insertion by direct laryngoscopy, videolaringoscopy or fiberoptic technique, the attending neonatologist will connect both the colorimetric capnometer and the proximal flow-sensor to the tracheal tube. If the flow sensor is not proximal but incorporated into the mechanical ventilator, the care provider will connect the capnometer only. During the procedure, the information given by the capnometer will be evaluated by the care provider performing the intubation, while the flow sensor information will be monitored only by a study investigator, who will not reveal any details to the care provider. In particular, the yellow color change by the capnometer and the presence of exhalation flow curves on the ventilator screen will be considered as confirmation of correct tracheal tube positioning, respectively.

Sponsors

Azienda Ospedaliera Universitaria Integrata Verona
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Masking description

Participants are newborns. The care provider will be the attending physician performing the tracheal intubation procedure as per local protocols, including the colourimetric capnometry analysis. However, he/she will remain blind and not aware of the flow sensor data until the end of the procedure.

Intervention model description

Simultaneous assignment, as the two methods to confirm the endotracheal tube position, namely the colorimetric capnometer and the flow sensor signal, will be evaluated simultaneously in each recruited patient.

Eligibility

Sex/Gender
ALL
Age
20 Minutes to 3 Months
Healthy volunteers
No

Inclusion criteria

Term and preterm infants requiring tracheal intubation within the neonatal intensive care unit, both in elective and emergency conditions.

Exclusion criteria

* intubation at birth * intubation during cardiopulmonary resuscitation * absence of informed consent by parents

Design outcomes

Primary

MeasureTime frameDescription
Time taken by the flow-sensor to indicate the correct or not correct positioning of the tracheal tube, compared with time taken by the colorimetric capnometer.Immediately after the tracheal intubation attemptTo compare the time (expressed in seconds) taken by the flow sensor and the colorimetric capnometer, respectively, to indicate the correct or not correct positioning of the tube in newborns undergoing tracheal intubation procedure during neonatal intensive care unit admission. The aim is to evaluate if the flow sensor of the mechanical ventilator can discriminate with similar or faster times the correct positioning of the tube during the tracheal intubation procedure compared to the colorimetric capnometer.
Number of mechanical breaths necessary to indicate the correct or not correct positioning of the tracheal tube by evaluating the flow-sensor curves and the color change of the colorimetric capnometer.Immediately after the tracheal intubation attemptTo compare the minimal number of mechanical breaths provided by the ventilator to indicate the correct or not correct positioning of the tube in newborns undergoing tracheal intubation procedure, either evaluating the flow-sensor curves and the color change of the colorimetric capnometer, respectively. The aim is to evaluate if the flow sensor of the mechanical ventilator can indicate with lower or equal number of mechanical breaths the correct positioning of the tube during tracheal intubation compared to the colorimetric capnometer.

Countries

Italy

Contacts

Primary ContactPaolo Biban, MD
PAOLO.BIBAN@AOVR.VENETO.IT+00390458122041
Backup ContactIrene Sibona, MD
irene.sibona@aovr.veneto.it00390458121825

Outcome results