Skip to content

Evaluation of Hepatitis B Virus (HBV) DNA Test As Point of Care Tool

Evaluation of Novel Hepatitis B DNA Test from Capillary Blood At the Point-of-care As a Tool to Enhance Clinical Management

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05144776
Acronym
HBVPOCT
Enrollment
268
Registered
2021-12-03
Start date
2022-11-17
Completion date
2024-06-05
Last updated
2025-03-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hepatitis B

Brief summary

This is a cross sectional observational study to asses the performance of two novel HBV DNA testing methodologies; a) dried blood spot sampling and b) fingerstick capillary blood using the Xpert® Hepatitis B Virus viral load assay. Both novel testing methodologies will be compared with venous blood tested using a gold standard HBV DNA assay. The sensitivity and specificity of the two novel testing will be evaluated. HBV viral load tests are essential to guide antiviral treatment eligibility and effectiveness. However, many people are unable to access these tests, particularly those living in remote or limited resources settings given high cost, or unavailable infrastructure. Simple, affordable and accessible HBV viral load tests are required to increase global access to HBV testing and treatment to meet the WHO HBV elimination targets. The GeneXpert Diagnostic Systems, the most common molecular point-of-care platform globally, has the potential to provide simple and affordable HBV viral load tests. Dried Blood Spot testing is also an affordable and accessible testing methodology particularly suited to remote and resource limited settings. This proof-of-concept study will assess the feasibility and diagnostic performance of Xpert® HBV Viral Load test and Dried Blood Spot testing for the quantitation of HBV DNA from fingerstick capillary samples.

Detailed description

This study will be a cross-sectional observational study and will assess the performance of a novel fingerstick HBV Viral Load and Dried Blood Spot tests within a total of 300 participants who will be recruited across a network of hepatitis clinics in Sydney, Australia. No treatment will be administered as part of this study. The Xpert HBV cartridge will be adapted to use fingerstick capillary blood instead of processed whole blood, and it's performance measured against a gold standard venous blood HBV DNA assay. Dried Blood Spot HBV DNA testing performance will also be measured against the gold standard venous blood HBV DNA assay. Secondary objectives of the study are to: 1) evaluate diagnostic performance of the Xpert® HBV Viral Load assay compared to standard of care testing, by patients' hepatitis B e-antigen status (among e-antigen positive and e-antigen negative patients). 2) Evaluate diagnostic performance of the Xpert® HBV Viral Load assay compared to standard of care testing, by HBV treatment status (among treatment naïve patients and those receiving treatment). 3) Evaluate diagnostic performance of the Xpert® HBV Viral Load assay compared to standard of care testing, by HBV DNA levels (among patients with HBV DNA \<20 IU/mL; between 20 and 2,000 IU/mL, between 2,000 and 20,000 IU/mL; between 20,000 and 200,000 IU/mL; and \>200,000 IU/mL).

Interventions

DIAGNOSTIC_TESTGeneXpert HBV DNA Viral Load Assay

The Xpert venous blood HBV DNA viral load assay will be adapted to operate using fingerstick capillary blood samples.

DIAGNOSTIC_TESTDried Blood Spot HBV DNA test

HBV DNA viral load will be measured from a fingerstick capillary dried blood spot sample using a gold standard HBV DNA viral load assay

Sponsors

Kirby Institute
Lead SponsorOTHER_GOV

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Have voluntarily signed the informed consent form, 18 years of age or older, HBsAg positive

Exclusion criteria

* Nil

Design outcomes

Primary

MeasureTime frameDescription
Assess performance of Xpert HBV DNA viral load assay using novel fingerstick capillary blood collection and HBV DNA viral load using fingerstick capillary Dried Blood Spot sample collection.At completion of enrolmentEvaluate the diagnostic performance of the Xpert HBV viral load assay and DBS samples using fingerstick capillary blood compared with the gold standard venous blood HBV DNA viral load assay

Secondary

MeasureTime frameDescription
Evaluate diagnostic performance of the novel tests by hepatitis B e-antigen statusAt completion of enrolmentEvaluate the diagnostic performance of the Xpert HBV viral load assay and DBS samples using fingerstick capillary blood compared with the gold standard venous blood HBV DNA viral load assay by 'Hepatitis B e-antigen status (among e-antigen positive and e-antigen negative patients).
Evaluate diagnostic performance of the novel tests by HBV treatment statusAt completion of enrolmentEvaluate the diagnostic performance of the Xpert HBV viral load assay and DBS samples using fingerstick capillary blood compared with the gold standard venous blood HBV DNA viral load assay by HBV treatment status (among treatment naïve patients and those receiving treatment)
Evaluate diagnostic performance of the novel tests by HBV DNA levelsAt completion of enrolmentEvaluate the diagnostic performance of the Xpert HBV viral load assay and DBS samples using fingerstick capillary blood compared with the gold standard venous blood HBV DNA viral load assay by HBV DNA levels (among patients with HBV DNA \<20 IU/mL; between 20 and 2,000 IU/mL, between 2,000 and 20,000 IU/mL; between 20,000 and 200,000 IU/mL; and \>200,000 IU/mL).

Countries

Australia

Outcome results

None listed