Hypoxemia, Physiological Stress

Brief summary

To investigate surgical mask use and high-intensity interval exercise across different environmental conditions.

Detailed description

Mask use in public settings is recommended to limit the spread of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) that causes the disease known as COVID-19 and endorsed by the Centers for Disease Control and Prevention (CDC) and the World Health Organization (WHO). Wearing a mask during exercise may have implications for recreational exercisers and athletes that train and compete at a high exercise intensities as it has been shown to limit ventilation (VE) and increase end-tidal CO2 compared to a no-mask control. For example, N95 masks are designed to fit more tightly around the nose and mouth than other types of masks and have been shown to reduce markers of maximal exercise performance compared to a no-mask control for individuals performing an incremental ramp protocol on a cycle ergometer. In contrast to N95 masks being reserved for health care workers, surgical masks certified by National Institute for Occupational Safety and Health are easily accessible to wear during exercise to reduce the risk of COVID-19 spread. Indeed, these masks fit more loosely than the N95, but did not reduce maximal power (Pmax), relative oxygen consumption (mL/kg/min), or test duration in two studies where participants performed a progressive maximal exercise test on a cycle ergometer. Further, surgical mask use during a progressive maximal cycling exercise protocol did not change cardiovascular, metabolic, and pulmonary measurements when compared to a no-mask condition in healthy individuals, with the exception of a decrease in maximal heart rate (HRmax). Another recent study using a progressive maximal cycling exercise protocol showed no change in (HRmax) using cycle ergometry when surgical mask use was compared to a no-mask condition. While this type of progressive maximal exercise test is frequently used for clinical and laboratory settings to assess cardiovascular, pulmonary, and metabolic markers, this type of exercise protocol is not often employed by athletes seeking to improve performance or recreational exercisers taking action to improve fitness. Because this exercise protocol is not used by athletes or recreational exercisers to train, it is difficult to translate the results of mask use during progressive maximal exercise tests to commonly practiced forms of exercise. In fact, a recent meta-analysis concludes that wearing a mask elicits a minimal impact on cardiovascular, respiratory, or metabolic variables across a wide array of exercise intensities and modalities, however, high intensity interval exercise (HIIE) was not included in this analysis, nor were hot environmental temperatures. Thus, the physiologic or metabolic responses while wearing a medical-grade surgical mask are not yet known with HIIE in both temperate and hot environments. High intensity interval exercise is a popular time-efficient training method that involves short high intensity bouts followed by either active (low/moderate intensity exercise) or passive (no exercise) rest bouts. High intensity interval exercise has been shown to be a safe and effective way to increase physical fitness or performance in a diverse population that include exercisers in recreational, competitive, and clinical settings. Further, as HIIE can be performed in either an indoor or outdoor environment and using a mask may increase the physiological and perceptual strain of the exercise depending on the temperature and humidity. In a hot environment (40°C and 20% humidity), no difference was found in skin temperature under or outside a KN95 mask in healthy males that performed 45-minutes of moderate intensity physical activity that mimicked movements required in occupational settings. Also, no difference was found in whole body thermal discomfort, and an increase in perceived breathlessness by 36% was observed. In addition, surgical mask use during 30 minutes of mild uphill treadmill exercise did not increase risk of heat stroke in a hot and humid environment. To date, no research study has investigated the effects of surgical mask use during HIIE in different environmental conditions. Therefore, the purpose of this study was to investigate the effects of surgical mask use during HIIE on cardiovascular, metabolic, thermoregulatory, and perceptual responses in temperate and hot environments. Methodsː In a randomized fashion, ten healthy participants completed two HIIE sessions in a 36°C hot (HIIE-HOT) and two HIIE sessions in a 23°C temperate environment (HIIE-TEMP) while wearing (MASK) and not wearing a surgical mask (CON). Procedures Anthropometrics and maximal Oxygen uptake measurements Before the experimental trials, participants visited the Exercise Physiology laboratories for anthropometrics and VO2max measurement. Body height was measured using a stadiometer (SECA, seca 216, Chino, CA, USA) and weight was measured using a digital scale (Cardinal DETECTO 758C, Webb City, MO). Then, participants completed a 5-minute warm-up at a self-selected exercise intensity prior to the VO2max test on an electrically braked cycle ergometer (Lode, Excalibur Sport, Groningen, The Netherlands). During the VO2max test, HR was measured using a Polar HR monitor (Polar, Polar H10, USA) with each test designed to last between 10 and 12 minutes. The starting resistance and the continuous increase in resistance (between 20-40 watts) throughout the test was based on the participants' self-reported fitness. Termination of the VO2max test occurred at volitional fatigue or when the participant could no longer maintain a cycling cadence of 60 revolutions per minute or higher. Gas-exchange was measured using a metabolic analyzer (Parvo Medics Inc, TrueOne 2400, Salt Lake City, UT) and data were analyzed using an 11-breath rolling average20. Primary criteria for a VO2max was categorized as an observed plateau that varied by less than 150 mlO2/min21. To determine a plateau using primary criteria, the mean of the absolute difference from each neighboring data point in the last 30 seconds of the 11-breath rolling average VO2 was compared against 150 mlO2/min21; if the average value was smaller, the test was categorized as a VO2max. In the absence of a plateau, a VO2max was confirmed if two of the three secondary criteria were met: 1) an RPE ≥17, 2) a respiratory exchange ratio (RER) of 1.1 or greater, and 3) a HR within 10 beats of estimated heart rate max using the Jones et al. equation (202 - 0.72 x age). The highest power output recorded from the VO2max test was used to calculate the high intensity and active recovery bouts for the HIIE sessions. High Intensity Interval Exercise Trials Before all HIIE sessions participant's hydration status was assessed measuring urine specific gravity (USG) using a handheld refractometer (Cole-Parmer, RSA-BR90A, Vernon Hills, IL). A USG measurement lower than 1.020 g/cc allowed participants to proceed to the HIIE sessions. If USG was greater than 1.020 g/cc, then participants consumed 500 ml of water, and were reassessed after 30 minutes. This water provision was only repeated twice if USG remained above 1.020 g/cc. A randomized cross over repeated measures design was used to compare cardiovascular, thermoregulatory, metabolic, and perceived responses before and during HIIE across four experimental trials performed during two visits. For each visit, which was separated by a minimum of 72 hours, the participants completed two HIIE sessions separated by 3 hours of rest. Each HIIE bout consisted of 10 bouts lasting 30 seconds performed at 85% Pmax followed by 90 seconds of active recovery at 30% Pmax. The HIIE sessions were performed in a temperate environment (23°C, 25% relative humidity) with (TEMP/MASK) and without a surgical mask (TEMP/CON), and in a hot environment (36°C, 14% relative humidity) with (HOT/MASK) and without a surgical mask (HOT/CON). During the exercise protocol participants were allowed to drink water. During HIIE sessions with a mask, all participants were instructed to wear the surgical mask snugly over their nose and mouth. The participants fitted the flexible metal plate within the surgical mask over the bridge of the nose and had the bottom of the mask cover underneath the chin. During the 3-hour rest period participants were provided a 350-calorie meal (7g of Fat; 64g Carbohydrate; 9g Protein) and water ad libitum. Cardiovascular Measurements Before every HIIE trial and after 5-minutes of seated rest, resting blood pressure was measured using a sphygmomanometer, and stethoscope. A cardiac impedance device (PhysioFlow®, NeuMeDex, Bristol, PA) calibrated per manufacturer guidelines was used to indirectly measure cardiac output (CO), stroke volume (SV), and HR. These measurements were taken continuously using 10-second averaging provided by the PhysioFlow® software during each HIIE session. Metabolic Measurements A near infra-red spectroscopy (NIRS) device (Moxy, Moxy Monitor System, MN, USA) was used to measure muscle tissue oxygenation every second during each HIIE session. The highest muscle tissue oxygenation value from each active rest period (MTO active rest %) was averaged for each HIIE session. Additionally, the lowest muscle tissue oxygenation (MTO during HIIE %) value per high intensity bout was recorded and averaged from each HIIE session. The difference of the average MTO active rest % and MTO during HIIE % was used to calculate the muscle tissue oxygenation difference (MTO difference %). All MTO measurements were taken on the dominant leg at a marked location on the vastus lateralis that would allow movement without interference from the NIRS device. A pulse oximeter (Caretaker, Caretaker Medical, USA) was used to measure SpO2 during HIIE. Blood lactate measurements (Lactate Plus, NOVA Biomedical, MA) were taken in duplicate at the ear lobe immediately before, and 5-minutes post HIIE. Perceptual Measurement before and during HIIE Borg's rating of perceived exertion (6 rest to 20 maximal effort) scale (RPE) and thermal sensation (0 very cold to 8 very hot) was measured immediately before and every four minutes into HIIE. A breathlessness scale (0 mm no breathlessness to 200 mm maximal breathlessness)was used immediately before, at 10-minutes, and immediately after exercise to record subjective change in difficulty breathing. The highest measurements for both RPE (peak RPE) and thermal sensation (peak thermal sensation) were recorded per HIIE session performed. Additionally, RPE (RPE avg) and dyspnea scores were averaged over time for every HIIE session. Thermal strain and hydration measurements During each HIIE exercise session continuous core temperature measurements were taken using rectal thermistors (Level 1 esophageal/rectal temperature probe, Smiths Medical, Minneapolis, MN, USA) connected to a thermometer (Precision 4000, YSI Incorporated, Yellow Springs, OH, USA) and monitored to ensure participant safety. Additionally, ∆ core temperature (i.e., the difference between peak core temperature and core temperature prior to starting exercise) and peak core temperature were recorded for each HIIE session. Sweat rate and dehydration were calculated from pre-exercise nude weight, post-exercise nude weight, water ingestion, and post-exercise urine output measurements27. Participants were asked to measure and report their pre-exercise and post-exercise nude weight using a digital scale (Cardinal DETECTO 758C, Webb City, MO) in a private room.

Interventions

DEVICEHigh-intensity interval exercise with surgical face mask in a temperate environment

Participants performed high-intensity interval exercise in a temperate environmental condition while wearing surgical face mask

DEVICEHigh-intensity interval exercise with surgical face mask in a hot environment

Participants performed high-intensity interval exercise in a hot environmental condition while wearing surgical face mask

OTHERHigh-intensity interval exercise without using a surgical face mask in a hot environment

Participants performed high-intensity interval exercise in a hot environmental condition without wearing a surgical face mask

OTHERHigh-intensity interval exercise without using a surgical face mask in a temperate environment

Participants performed high-intensity interval exercise in a temperate environmental condition without wearing a surgical face mask

Sponsors

University of New Mexico
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
SEQUENTIAL
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE

Intervention model description

non-blinded randomized repeated measures crossover

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* 18 years of age or older and, are able to both speak and read in English. * Physically active and used to high-intensity exercise. * No known serious medical conditions.

Exclusion criteria

* Vulnerable populations such as children, minors, pregnant women, and intellectually challenged individuals. * Those with cardiovascular, renal, metabolic, or chronic respiratory disease, smokers or those who have quit smoking less than 6 months ago, and those who use an inhaler to control for exercise-induced asthma. * In addition,

Design outcomes

Primary

MeasureTime frameDescription
Average Stroke Volume Over the Course of High-intensity Interval ExerciseDuring a 20-minute high-intensity interval exercise sessionStroke volume measured in milliliters using a cardiograph impedance device (PhysioFlow)
Average Cardiac Output Over the Course of High-intensity Interval ExerciseDuring a 20-minute high-intensity interval exercise sessionCardiac output measured in liters per minute using a cardiograph impedance device (PhysioFlow)
Average Heart Rate Over the Course of High-intensity Interval ExerciseDuring a 20-minute high-intensity interval exercise sessionHeart rate measured in beats per minute using a cardiograph impedance device (PhysioFlow)
Peak Core TemperatureThe highest value recorded during a 20-minute high-intensity interval exercise sessionThe highest core body temperature measured in degrees Celsius during high-intensity interval exercise
Change From Baseline (Rest) in Core Temperature to the End of ExerciseBaseline (rest) prior to exercise and immediately after 20-minutes of exerciseThe difference in core temperature from rest prior to exercise and at the end of exercise
Sweat Rate During ExerciseChange from Baseline (rest) prior to exercise and after 20-minutes of exerciseAmount of fluid loss through sweat over the course of exercise reported in milliliters per hour. This was calculated by taking difference of pre- and post-exercise body weight in kilograms while accounting for fluid intake and urine volume.
Dehydration After ExerciseChange from baseline at rest and after 20-minutes of exercisePercentage of body weight fluid loss represented as a percentage of change from baseline and after 20 minutes of exercise
Lactate at 5-minutes Post Exercise5-minutes post exerciseBlood lactate measured in millimoles per liter. This measurement was taken at the earlobe using a sterile lancet to obtain a drop of blood for analysis.
Average Blood Oxygen Saturation Over the Course of High-intensity Interval ExerciseDuring a 20-minute high-intensity interval exercise sessionA pulse oximeter was placed on a finger and used to measure the percentage of oxygen saturated blood.
Average Muscle Tissue Oxygenation During the High-intensity Portions of the Exercise SessionDuring a 20-minute high-intensity interval exercise sessionA near-infra red spectroscopy device was placed over the vastus lateralis of the dominant leg. This device measured the percentage of oxygenated muscle tissue.
Average Muscle Tissue Oxygenation During the Active Rest Portions of the Exercise SessionDuring a 20-minute high-intensity interval exercise sessionA near-infra red spectroscopy device was placed over the vastus lateralis of the dominant leg. This device measured the percentage of oxygenated muscle tissue.
Average Change in Muscle Tissue Oxygenation Between the Active Rest and High Intensity Portions Over the Course of High-intensity Interval Exercise.During a 20-minute high-intensity interval exercise sessionThis value was calculated by subtracting the average percentage of muscle tissue oxygenation during active rest portion of the exercise from the average percentage of muscle tissue oxygenation during the high-intensity portion of the exercise.
Average Perceived Dyspnea Score Over the Course of High-intensity Interval ExerciseMeasurements were taken prior to, 10 minutes into exercise, and immediately after exercise (at 20 minutes). These measurements were averaged to form a single value for the high-intensity interval exercise session.The participants were presented a vertical 200 millimeter long line with the top of the line labeled No Difficulty and the bottom of the line labeled Most Difficult. The participants were then asked to indicated on this line how difficult it was to breath by pointing to a point along the line presented to them. Once the participant indicated along the line how difficult it was to breath the researcher then marked the spot on the line with a pen. To quantify the measurement, the distance, measured in millimeters, was taken from the No Difficulty end of the line (0 millimeters) to the indicated mark with the maximum difficulty recorded as 200 millimeters.
Peak Thermal Sensation Over the Course of High-intensity Interval ExerciseBaseline (rest) and every four minutes that was assessed up to 20 minutes into exercise. The highest value was recorded for each exercise session.Participants were asked to indicate on a visual scale from 0 (very cold) to 8 (very hot) their perceived thermal sensation. The highest recorded value was reported.
Average Thermal Sensation Over the Course of High-intensity Interval ExerciseBaseline (rest) and every four minutes that was assessed up to 20 minutes into exercise. These values were averaged into one value for each exercise session.Participants were asked to indicate on a visual scale from 0 (very cold) to 8 (very hot) their perceived thermal sensation.
Peak Rating of Perceived Exertion Over the Course of High-intensity Interval ExerciseBaseline (rest) and every four minutes that was assessed up to 20 minutes into exercise. The highest value was recorded for each exercise session.Participants were asked to indicate on a visual scale from 6 (no exertion) to 20 (maximal exertion) their perceived difficulty of exercise. The highest recorded value was reported.
Averaged Rating of Perceived Exertion Over the Course of High-intensity Interval ExerciseBaseline (rest) and every four minutes that assessed up to 20 minutes into exercise. These values were averaged into one value for each exercise session.Participants were asked to indicate on a visual scale from 6 (no exertion) to 20 (maximal exertion) their perceived difficulty of exercise. The highest recorded value was reported.
Peak Heart Rate Over the Course of High-intensity Interval ExerciseDuring a 20-minute high-intensity interval exercise sessionPeak heart rate measured in beats per minute using a cardiograph impedance device (PhysioFlow)

Countries

United States

Participant flow

Pre-assignment details

Participants were excluded if in the last 6 months they smoked, performed less than 150 minutes of moderate-intensity exercise per week as defined by the American College of Sports Medicine guidelines, had a cardiorespiratory fitness classification below the 50th percentile for age and sex according to the American College Sport Medicine guidelines, reported no experience performing high intensity interval exercise, or had any known medical disease.

Participants by arm

ArmCount
Participation in Four Different Conditions
Ten recreationally trained participants (5 males; 5 females) were recruited for this study. Participants were free from known cardiovascular, renal, metabolic, or chronic respiratory disease (i.e., asthma) as determined from a health history questionnaire. Participants were excluded if in the last 6 months they smoked and performed less than 150 minutes of moderate-intensity exercise per week, had a maximal oxygen consumption capacity below the 50th percentile for age and sex according to the American College of Sport Medicine guidelines for aerobic fitness, or reported no experience performing high intensity interval exercise. A pregnancy test was completed for female participants to include only non-pregnant participants. A randomized non-counterbalanced crossover repeated measures design was used to compare cardiovascular, thermoregulatory, metabolic, and perceived responses before and during high intensity across four experimental trials performed during two visits. The high intensity interval exercise sessions were performed in a temperate environment (23°C, 25% relative humidity) with and without a surgical mask, and in a hot environment (36°C, 14% relative humidity) with and without a surgical mask.
10
Total10

Baseline characteristics

CharacteristicParticipation in Four Different Conditions
Age, Continuous27.8 years
STANDARD_DEVIATION 4.8
Height (cm)173.1 centimeters
STANDARD_DEVIATION 7.5
Max Power (Watts)284.0 Watts
STANDARD_DEVIATION 78
Race and Ethnicity Not Collected— Participants
Resting DBP (mmHg)75.4 millimeters mercury
STANDARD_DEVIATION 5.9
Resting HR (bpm)64 beats per minute
STANDARD_DEVIATION 9
Resting SBP (mmHg)113.0 millimeters mercury
STANDARD_DEVIATION 8
Sex: Female, Male
Female
5 Participants
Sex: Female, Male
Male
5 Participants
VO2max (mlO2/kg/min)49.4 mlO2/kg/min
STANDARD_DEVIATION 7.4
Weight (kg)68.6 kilograms
STANDARD_DEVIATION 11.5

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
EG002
affected / at risk
EG003
affected / at risk
deaths
Total, all-cause mortality
0 / 100 / 100 / 100 / 10
other
Total, other adverse events
0 / 100 / 100 / 100 / 10
serious
Total, serious adverse events
0 / 100 / 100 / 100 / 10

Outcome results

Primary

Average Blood Oxygen Saturation Over the Course of High-intensity Interval Exercise

A pulse oximeter was placed on a finger and used to measure the percentage of oxygen saturated blood.

Time frame: During a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Blood Oxygen Saturation Over the Course of High-intensity Interval Exercise93.5 percent SpO2Standard Deviation 3.63
Mask TemperateAverage Blood Oxygen Saturation Over the Course of High-intensity Interval Exercise93.7 percent SpO2Standard Deviation 1.5
No Mask HotAverage Blood Oxygen Saturation Over the Course of High-intensity Interval Exercise93.8 percent SpO2Standard Deviation 2.3
Mask HotAverage Blood Oxygen Saturation Over the Course of High-intensity Interval Exercise94.0 percent SpO2Standard Deviation 1.4
p-value: 0.4612x2 Repeated Measures ANOVA
p-value: 0.8772x2 Repeated Measures ANOVA
p-value: 0.9192x2 Repeated Measures ANOVA
Primary

Average Cardiac Output Over the Course of High-intensity Interval Exercise

Cardiac output measured in liters per minute using a cardiograph impedance device (PhysioFlow)

Time frame: During a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Cardiac Output Over the Course of High-intensity Interval Exercise15.7 L/minStandard Deviation 2.5
Mask TemperateAverage Cardiac Output Over the Course of High-intensity Interval Exercise15.8 L/minStandard Deviation 2.6
No Mask HotAverage Cardiac Output Over the Course of High-intensity Interval Exercise15.3 L/minStandard Deviation 2.4
Mask HotAverage Cardiac Output Over the Course of High-intensity Interval Exercise16.5 L/minStandard Deviation 2.2
p-value: 0.7492x2 Repeated Measures ANOVA
p-value: 0.3112x2 Repeated Measures ANOVA
p-value: 0.3682x2 Repeated Measures ANOVA
Primary

Average Change in Muscle Tissue Oxygenation Between the Active Rest and High Intensity Portions Over the Course of High-intensity Interval Exercise.

This value was calculated by subtracting the average percentage of muscle tissue oxygenation during active rest portion of the exercise from the average percentage of muscle tissue oxygenation during the high-intensity portion of the exercise.

Time frame: During a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Change in Muscle Tissue Oxygenation Between the Active Rest and High Intensity Portions Over the Course of High-intensity Interval Exercise.25.6 percent SmO2Standard Deviation 10
Mask TemperateAverage Change in Muscle Tissue Oxygenation Between the Active Rest and High Intensity Portions Over the Course of High-intensity Interval Exercise.27.5 percent SmO2Standard Deviation 10.2
No Mask HotAverage Change in Muscle Tissue Oxygenation Between the Active Rest and High Intensity Portions Over the Course of High-intensity Interval Exercise.32.4 percent SmO2Standard Deviation 12.4
Mask HotAverage Change in Muscle Tissue Oxygenation Between the Active Rest and High Intensity Portions Over the Course of High-intensity Interval Exercise.27.4 percent SmO2Standard Deviation 13.7
p-value: 0.292x2 Repeated Measures ANOVA
p-value: 0.5272x2 Repeated Measures ANOVA
p-value: 0.0452x2 Repeated Measures ANOVA
Primary

Averaged Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise

Participants were asked to indicate on a visual scale from 6 (no exertion) to 20 (maximal exertion) their perceived difficulty of exercise. The highest recorded value was reported.

Time frame: Baseline (rest) and every four minutes that assessed up to 20 minutes into exercise. These values were averaged into one value for each exercise session.

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAveraged Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise13.3 score on a scaleStandard Deviation 1.4
Mask TemperateAveraged Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise13.3 score on a scaleStandard Deviation 1.2
No Mask HotAveraged Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise13.5 score on a scaleStandard Deviation 1.2
Mask HotAveraged Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise14.3 score on a scaleStandard Deviation 1.3
p-value: 0.0242x2 Repeated Measures ANOVA
p-value: 0.0022x2 Repeated Measures ANOVA
p-value: 0.0142x2 Repeated Measures ANOVA
Primary

Average Heart Rate Over the Course of High-intensity Interval Exercise

Heart rate measured in beats per minute using a cardiograph impedance device (PhysioFlow)

Time frame: During a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Heart Rate Over the Course of High-intensity Interval Exercise144 beats per minuteStandard Deviation 21
Mask TemperateAverage Heart Rate Over the Course of High-intensity Interval Exercise143 beats per minuteStandard Deviation 20
No Mask HotAverage Heart Rate Over the Course of High-intensity Interval Exercise148 beats per minuteStandard Deviation 18
Mask HotAverage Heart Rate Over the Course of High-intensity Interval Exercise149 beats per minuteStandard Deviation 18
p-value: 0.0032x2 repeated measures ANOVA
p-value: 0.9332x2 repeated measures ANOVA
p-value: 0.3442x2 repeated measures ANOVA
Primary

Average Muscle Tissue Oxygenation During the Active Rest Portions of the Exercise Session

A near-infra red spectroscopy device was placed over the vastus lateralis of the dominant leg. This device measured the percentage of oxygenated muscle tissue.

Time frame: During a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Muscle Tissue Oxygenation During the Active Rest Portions of the Exercise Session56.7 percent SmO2Standard Deviation 10.4
Mask TemperateAverage Muscle Tissue Oxygenation During the Active Rest Portions of the Exercise Session58.8 percent SmO2Standard Deviation 15.9
No Mask HotAverage Muscle Tissue Oxygenation During the Active Rest Portions of the Exercise Session55.8 percent SmO2Standard Deviation 12.7
Mask HotAverage Muscle Tissue Oxygenation During the Active Rest Portions of the Exercise Session62.0 percent SmO2Standard Deviation 11.4
p-value: 0.3752x2 Repeated Measures ANOVA
p-value: 0.1782x2 Repeated Measures ANOVA
p-value: 0.5332x2 Repeated Measures ANOVA
Primary

Average Muscle Tissue Oxygenation During the High-intensity Portions of the Exercise Session

A near-infra red spectroscopy device was placed over the vastus lateralis of the dominant leg. This device measured the percentage of oxygenated muscle tissue.

Time frame: During a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Muscle Tissue Oxygenation During the High-intensity Portions of the Exercise Session31.0 percent SmO2Standard Deviation 17.8
Mask TemperateAverage Muscle Tissue Oxygenation During the High-intensity Portions of the Exercise Session31.4 percent SmO2Standard Deviation 21.5
No Mask HotAverage Muscle Tissue Oxygenation During the High-intensity Portions of the Exercise Session23.5 percent SmO2Standard Deviation 18.8
Mask HotAverage Muscle Tissue Oxygenation During the High-intensity Portions of the Exercise Session34.7 percent SmO2Standard Deviation 21.7
p-value: 0.4662x2 Repeated Measures ANOVA
p-value: 0.1862x2 Repeated Measures ANOVA
p-value: 0.082x2 Repeated Measures ANOVA
Primary

Average Perceived Dyspnea Score Over the Course of High-intensity Interval Exercise

The participants were presented a vertical 200 millimeter long line with the top of the line labeled No Difficulty and the bottom of the line labeled Most Difficult. The participants were then asked to indicated on this line how difficult it was to breath by pointing to a point along the line presented to them. Once the participant indicated along the line how difficult it was to breath the researcher then marked the spot on the line with a pen. To quantify the measurement, the distance, measured in millimeters, was taken from the No Difficulty end of the line (0 millimeters) to the indicated mark with the maximum difficulty recorded as 200 millimeters.

Time frame: Measurements were taken prior to, 10 minutes into exercise, and immediately after exercise (at 20 minutes). These measurements were averaged to form a single value for the high-intensity interval exercise session.

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Perceived Dyspnea Score Over the Course of High-intensity Interval Exercise14 units on a scaleStandard Deviation 13
Mask TemperateAverage Perceived Dyspnea Score Over the Course of High-intensity Interval Exercise44 units on a scaleStandard Deviation 17
No Mask HotAverage Perceived Dyspnea Score Over the Course of High-intensity Interval Exercise18 units on a scaleStandard Deviation 15
Mask HotAverage Perceived Dyspnea Score Over the Course of High-intensity Interval Exercise58 units on a scaleStandard Deviation 22
p-value: 0.0182x2x3 Repeated Measures ANOVA
p-value: <0.0012x2x3 Repeated Measures ANOVA
p-value: 0.0352x2x3 Repeated Measures ANOVA
Primary

Average Stroke Volume Over the Course of High-intensity Interval Exercise

Stroke volume measured in milliliters using a cardiograph impedance device (PhysioFlow)

Time frame: During a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Stroke Volume Over the Course of High-intensity Interval Exercise109.9 millilitersStandard Deviation 19.5
Mask TemperateAverage Stroke Volume Over the Course of High-intensity Interval Exercise109.2 millilitersStandard Deviation 15.3
No Mask HotAverage Stroke Volume Over the Course of High-intensity Interval Exercise104.5 millilitersStandard Deviation 16
Mask HotAverage Stroke Volume Over the Course of High-intensity Interval Exercise101.5 millilitersStandard Deviation 36.4
Comparison: A 2x2 repeated measures ANOVA was performed to investigate statistical differences for all variables across the four conditions. Both main and interaction effects were calculated along with effect size, reported as partial ⴄ2 as provided by the statistical software JASP (version 0.14.1.0).p-value: 0.1172x2 Repeated Measures ANOVA
p-value: 0.8322x2 Repeated Measures ANOVA
p-value: 0.8792x2 Repeated Measures ANOVA
Primary

Average Thermal Sensation Over the Course of High-intensity Interval Exercise

Participants were asked to indicate on a visual scale from 0 (very cold) to 8 (very hot) their perceived thermal sensation.

Time frame: Baseline (rest) and every four minutes that was assessed up to 20 minutes into exercise. These values were averaged into one value for each exercise session.

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateAverage Thermal Sensation Over the Course of High-intensity Interval Exercise5.3 score on a scaleStandard Deviation 0.7
Mask TemperateAverage Thermal Sensation Over the Course of High-intensity Interval Exercise5.4 score on a scaleStandard Deviation 0.7
No Mask HotAverage Thermal Sensation Over the Course of High-intensity Interval Exercise6.5 score on a scaleStandard Deviation 0.4
Mask HotAverage Thermal Sensation Over the Course of High-intensity Interval Exercise6.6 score on a scaleStandard Deviation 0.4
p-value: <0.0012x2 Repeated Measures ANOVA
p-value: 0.4872x2 Repeated Measures ANOVA
p-value: 0.792x2 Repeated Measures ANOVA
Primary

Change From Baseline (Rest) in Core Temperature to the End of Exercise

The difference in core temperature from rest prior to exercise and at the end of exercise

Time frame: Baseline (rest) prior to exercise and immediately after 20-minutes of exercise

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateChange From Baseline (Rest) in Core Temperature to the End of Exercise0.77 °CStandard Deviation 0.22
Mask TemperateChange From Baseline (Rest) in Core Temperature to the End of Exercise0.54 °CStandard Deviation 0.26
No Mask HotChange From Baseline (Rest) in Core Temperature to the End of Exercise0.56 °CStandard Deviation 0.2
Mask HotChange From Baseline (Rest) in Core Temperature to the End of Exercise0.64 °CStandard Deviation 0.17
p-value: 0.3942x2 Repeated Measures ANOVA
p-value: 0.1572x2 Repeated Measures ANOVA
p-value: 0.0152x2 Repeated Measures ANOVA
Primary

Dehydration After Exercise

Percentage of body weight fluid loss represented as a percentage of change from baseline and after 20 minutes of exercise

Time frame: Change from baseline at rest and after 20-minutes of exercise

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateDehydration After Exercise-0.76 percentage of changeStandard Deviation 0.32
Mask TemperateDehydration After Exercise-0.77 percentage of changeStandard Deviation 0.26
No Mask HotDehydration After Exercise-0.81 percentage of changeStandard Deviation 0.25
Mask HotDehydration After Exercise-0.67 percentage of changeStandard Deviation 0.28
p-value: 0.7862x2 Repeated Measures ANOVA
p-value: 0.182x2 Repeated Measures ANOVA
p-value: 0.2392x2 Repeated Measures ANOVA
Primary

Lactate at 5-minutes Post Exercise

Blood lactate measured in millimoles per liter. This measurement was taken at the earlobe using a sterile lancet to obtain a drop of blood for analysis.

Time frame: 5-minutes post exercise

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateLactate at 5-minutes Post Exercise4.3 mmol/LStandard Deviation 1.7
Mask TemperateLactate at 5-minutes Post Exercise4.2 mmol/LStandard Deviation 2
No Mask HotLactate at 5-minutes Post Exercise4.9 mmol/LStandard Deviation 2.2
Mask HotLactate at 5-minutes Post Exercise4.5 mmol/LStandard Deviation 1.9
p-value: 0.1342x2 Repeated Measures ANOVA
p-value: 0.6212x2 Repeated Measures ANOVA
p-value: 0.5532x2 Repeated Measures ANOVA
Primary

Peak Core Temperature

The highest core body temperature measured in degrees Celsius during high-intensity interval exercise

Time frame: The highest value recorded during a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperatePeak Core Temperature37.76 °CStandard Deviation 0.28
Mask TemperatePeak Core Temperature37.64 °CStandard Deviation 0.29
No Mask HotPeak Core Temperature37.65 °CStandard Deviation 0.24
Mask HotPeak Core Temperature37.71 °CStandard Deviation 0.38
p-value: 0.7892x2 Repeated Measures ANOVA
p-value: 0.7392x2 Repeated Measures ANOVA
p-value: 0.1582x2 Repeated Measures ANOVA
Primary

Peak Heart Rate Over the Course of High-intensity Interval Exercise

Peak heart rate measured in beats per minute using a cardiograph impedance device (PhysioFlow)

Time frame: During a 20-minute high-intensity interval exercise session

ArmMeasureValue (MEAN)Dispersion
No Mask TemperatePeak Heart Rate Over the Course of High-intensity Interval Exercise164 beats per minuteStandard Deviation 20
Mask TemperatePeak Heart Rate Over the Course of High-intensity Interval Exercise164 beats per minuteStandard Deviation 17
No Mask HotPeak Heart Rate Over the Course of High-intensity Interval Exercise169 beats per minuteStandard Deviation 16
Mask HotPeak Heart Rate Over the Course of High-intensity Interval Exercise169 beats per minuteStandard Deviation 16
p-value: 0.0122x2 Repeated Measures ANOVA
p-value: 0.8932x2 Repeated Measures ANOVA
p-value: 0.9692x2 Repeated Measures ANOVA
Primary

Peak Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise

Participants were asked to indicate on a visual scale from 6 (no exertion) to 20 (maximal exertion) their perceived difficulty of exercise. The highest recorded value was reported.

Time frame: Baseline (rest) and every four minutes that was assessed up to 20 minutes into exercise. The highest value was recorded for each exercise session.

ArmMeasureValue (MEAN)Dispersion
No Mask TemperatePeak Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise15 score on a scaleStandard Deviation 2
Mask TemperatePeak Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise15 score on a scaleStandard Deviation 1
No Mask HotPeak Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise15 score on a scaleStandard Deviation 2
Mask HotPeak Rating of Perceived Exertion Over the Course of High-intensity Interval Exercise16 score on a scaleStandard Deviation 2
p-value: 0.0892x2 Repeated Measures ANOVA
p-value: 0.2972x2 Repeated Measures ANOVA
p-value: 0.1112x2 Repeated Measures ANOVA
Primary

Peak Thermal Sensation Over the Course of High-intensity Interval Exercise

Participants were asked to indicate on a visual scale from 0 (very cold) to 8 (very hot) their perceived thermal sensation. The highest recorded value was reported.

Time frame: Baseline (rest) and every four minutes that was assessed up to 20 minutes into exercise. The highest value was recorded for each exercise session.

ArmMeasureValue (MEAN)Dispersion
No Mask TemperatePeak Thermal Sensation Over the Course of High-intensity Interval Exercise5.9 score on a scaleStandard Deviation 0.9
Mask TemperatePeak Thermal Sensation Over the Course of High-intensity Interval Exercise5.9 score on a scaleStandard Deviation 0.9
No Mask HotPeak Thermal Sensation Over the Course of High-intensity Interval Exercise6.5 score on a scaleStandard Deviation 0.4
Mask HotPeak Thermal Sensation Over the Course of High-intensity Interval Exercise6.6 score on a scaleStandard Deviation 0.4
p-value: <0.0012x2 Repeated Measures ANOVA
p-value: 0.6782x2 Repeated Measures ANOVA
p-value: 0.6782x2 Repeated Measures ANOVA
Primary

Sweat Rate During Exercise

Amount of fluid loss through sweat over the course of exercise reported in milliliters per hour. This was calculated by taking difference of pre- and post-exercise body weight in kilograms while accounting for fluid intake and urine volume.

Time frame: Change from Baseline (rest) prior to exercise and after 20-minutes of exercise

ArmMeasureValue (MEAN)Dispersion
No Mask TemperateSweat Rate During Exercise2097 milliliters per hourStandard Deviation 1258
Mask TemperateSweat Rate During Exercise1921 milliliters per hourStandard Deviation 690
No Mask HotSweat Rate During Exercise2262 milliliters per hourStandard Deviation 1199
Mask HotSweat Rate During Exercise1793 milliliters per hourStandard Deviation 1254
p-value: 0.962x2 Repeated Measures ANOVA
p-value: 0.0732x2 Repeated Measures ANOVA
p-value: 0.5032x2 Repeated Measures ANOVA