Skip to content

Hemodynamic OptimizaTion in Sitting POsition Surgery Trial

Continuous Non-invasive Blood Pressure Monitoring to Increase Hemodynamic Stability During Sitting Position Orthopedic Surgery: Prospective Randomized Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05143632
Acronym
HOTSPOT
Enrollment
60
Registered
2021-12-03
Start date
2022-07-28
Completion date
2024-11-30
Last updated
2025-02-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hemodynamic Instability, Blood Pressure, Low, Orthopedic Disorder

Brief summary

Intraoperative hypotension (MAP \<65 mmHg) in patients undergoing general anesthesia is a notable risk factor for the development of post-operative complications including acute kidney injury (AKI), myocardial injury, stroke and delirium, and is strongly associated with increased mortality. Moreover, the mean and systolic blood pressure values tend to undergo significant fluctuations with different positions assumed by the patient during surgery. Since severe hypotensive phenomena are connected with cerebral hypoperfusion and are associated with negative outcomes, close monitoring of blood pressure is necessary. The primary endpoint of this study is to evaluate the number of hypotensive episodes, their quality and their duration in patients monitored with the oscillometric intermittent noninvasive blood pressure method compared to patients with continuous noninvasive monitoring using ClearSight during orthopedic surgery in sitting position performed under general anesthesia and with interscalene block. The measure of hypotension will be expressed (in mmHg) with the TWA-MAP value (time-weighted average intraoperative MAP) to define the severity and duration of the hypotensive episode. Secondary endpoints include: episodes of cerebral desaturation measured by brain oximetry, number of severe hypotensive episodes (MAP \<60 mmHg or \<50 mmHg) recorded; time to event: how long does it take for the medical staff to correct the hypotensive episode (treated according to the planned protocol); quantity of vasopressors and/or fluids used to correct the hypotensive event; incidence of perioperative adverse cardiac events and acute kidney injury. The primary hypothesis is that continuous non-invasive monitoring using ClearSight reduces the incidence of intraoperative hypotensive events (defined by mean arterial pressure below a value of 65 mmHg for more than 1 minute) and the duration of the events themselves, leading to an improvement in patients' outcomes.

Detailed description

Intraoperative hypotension (MAP \<65 mmHg) in patients undergoing general anesthesia is a notable risk factor for the development of post-operative complications including acute kidney injury (AKI), myocardial injury, stroke and delirium, and is strongly associated with increased mortality. Moreover, the mean and systolic blood pressure values tend to undergo significant fluctuations with different positions assumed by the patient during surgery, decreasing in the transition from the supine position to the sitting position (beach chair position) typically used during surgery that involves the anatomical district of the shoulder or proximal humerus. Since severe hypotensive phenomena are connected with cerebral hypoperfusion and are associated with negative outcomes, close monitoring of blood pressure is necessary. The investigators have introduced in clinical practice the use of non-invasive ClearSight sensor (Edwards Lifesciences Corp, Irvine CA, USA), which uses the volume-clamp and Physiocal technologies to obtain continuously calibrated blood pressure values and hemodynamic parameters. The primary endpoint of this study is to evaluate the number of hypotensive episodes, their quality and their duration in patients monitored with the oscillometric intermittent noninvasive blood pressure method compared to patients with continuous noninvasive monitoring using ClearSight during orthopedic surgery in seated position performed under general anesthesia and with interscalene block. The measure of hypotension will be expressed with the TWA-MAP value (time-weighted average intraoperative MAP) to define the severity and duration of the hypotensive episode. For a subgroup of patients, brain oximetry will be monitored using the ForeSight system to record episodes of cerebral desaturation. Secondary endpoints include: the incidence of brain oxygen desaturation measured using the ForeSight system, number of severe hypotensive episodes (MAP \<60 mmHg or \<50 mmHg) recorded; time to event: how long does it take for the medical staff to correct the hypotensive episode (treated according to the planned protocol); quantity of vasopressors and/or fluids used to correct the hypotensive event; incidence of perioperative adverse cardiac events and acute kidney injury. The primary hypothesis is that continuous non-invasive monitoring using ClearSight reduces the incidence of intraoperative hypotensive events (defined by mean arterial pressure below a value of 65 mmHg for more than 1 minute) and the duration of the events themselves, leading to an improvement in patients' outcomes.

Interventions

The primary hypothesis is that continuous non-invasive monitoring using ClearSight reduces the incidence of intraoperative hypotensive events (defined by mean arterial pressure below a value of 65 mmHg for more than 1 minute) and the duration of the events themselves, leading to an improvement in patients' outcomes.

Sponsors

Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1\. patients candidate for elective orthopedic surgery in sitting position under general anesthesia + interscalene block

Exclusion criteria

1. non-elective patients (acute trauma) and hemodynamically unstable patients 2. vascular system pathologies 3. pregnant women 4. patient refusal to participate to the study

Design outcomes

Primary

MeasureTime frameDescription
TWA MAP < 65 mmhg (expressed in mmHg)Surgery timeThe measure of hypotension will be expressed with the TWA-MAP value (time-weighted average intraoperative MAP) in mmHg to define the severity and duration of the hypotensive episode. The TWA MAP under a threshold of 65 mmHg will be calculated as the area between 65 mmHg threshold and the curve of the MAP measurements divided by total continuous reading time in minutes.

Secondary

MeasureTime frameDescription
Incidence of cerebral oxygen desaturation episodeSurgery timeThe number of severe hypotensive episodes (StO2 \<60%) recorded in the two groups.
Rate of severe hypotensive episodes (MAP <60 mmHg or <50 mmHg)Surgery timeThe number of severe hypotensive episodes (MAP \<60 mmHg or \<50 mmHg) recorded.
Time to event (in seconds)Surgery timeHow long does it take for the medical staff to correct the hypotensive episode (in seconds).

Other

MeasureTime frameDescription
Incidence of perioperative adverse cardiac events.30 postoperative days.Major Adverse Cardiovascular Events - MACE - will be defined, according to the 3 points MACE, as a composite of non fatal stroke, non fatal myocardial infarction and cardiovascular death occurred within 30 postoperative days.
Incidence of perioperative acute kidney injury.48 postoperative hours.Acute Kidney Iniury - AKI - will be defined, according to the KDIGO criteria, as an increase in serum creatinine by greather than or equal to 0.3 mg/dL within 48 postoperative hours.
Quantity of vasopressors and/or fluidsSurgery timeQuantity of vasopressors (expressed in mg) and/or fluids (expressed in ml) used to correct the hypotensive events.

Countries

Italy

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026