Skip to content

Assessment of a Femtosecond Laser to Perform Capsulorhexis During Cataract Surgery

Assessment of a Hand-held Femtosecond Laser to Perform Anterior Capsulorhexis During Cataract Surgery

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05141370
Enrollment
83
Registered
2021-12-02
Start date
2022-02-03
Completion date
2023-04-03
Last updated
2023-10-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract Surgery

Brief summary

This study is a Pre-market first-in-man clinical investigation to validate performance of a hand-held femtosecond laser named CATSYS.

Detailed description

Interventional, prospective, longitudinal (follow-up: 30 ± 10 days), single-arm, single center, open trial. The first-in-man character of this investigation relies on the ergonomics of CATSYS (handpiece), and not on the laser technique, which is similar to other FLACS. The purpose of the clinical investigation is to document the compliance of the investigational medical device with the general requirements of performance, safety and clinical benefit, in order to complete existing data and obtaining CE-mark for CATSYS.

Interventions

DEVICEcataract surgery with CATSYS

patient diagnosed with cataract requiring surgery will have an anterior capsulorhexis with CATSYS

Sponsors

Ilasis Laser
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Diagnosed with cataract requiring surgery according to current guidelines; * Eligible to lens removal by phacoemulsification and replacement by a prosthetic lens under local anesthesia; * Who have been informed and gave informed consent to participate in the study.

Exclusion criteria

* Eye with an anterior chamber depth \< 2.5 mm or \> 3.8 mm; * Corneal disease or pathology that precludes applanation of the cornea or transmission of laser wavelength or distortion of laser light; * Eye with a poorly dilating pupil or other defect of the pupil that prevents the iris from adequate retraction peripherally; * Patient with residual, recurrent, active ocular or eyelid disease, including any corneal abnormality (for example, recurrent corneal erosion, severe basement membrane disease) in either eye; * History of steroid-responsive rise in IOP, glaucoma, or preoperative IOP\>21 mm Hg in either eye; * Lens/zonular instability such as, but not restricted to, Marfan's Syndrome, pseudoexfoliation syndrome, etc; * Previous intraocular or corneal surgery of any kind, including any type of surgery for either refractive or therapeutic purposes in either eye; * Any recent penetrating incision of the eyeball; * Tilt of lens \> 7; * Presence of any obstacle that may interfere with the stabilization of the device on the limbus: pterygium, limbic tumor, etc; * Pregnant or lactating woman; * Patient with any contra-indication to neosynephrine, tropicamide and oxybuprocaïne; * Patient presenting any contraindications to cataract surgery under local anesthesia (ex: allergy to anesthetic drops; neurodegenerative disease; schizophrenia; severe anxiety; etc.); * Patient who participates to another clinical trial (except observational studies), or in the exclusion period of another clinical trial; * Patient under guardianship, trusteeship or deprived of liberty; * Patient not affiliated to the French social security system; * Patient unable to participate in the study for psychiatric, cognitive or linguistic reasons.

Design outcomes

Primary

MeasureTime frameDescription
Continuity of the capsulorhexis (success / failure)During surgerySuccess achieved if: * the anterior capsule is completely cut (rhexis is free floating or easy to remove) * AND there are no peripheric tears that can generate the rupture of the capsule at the end of rhexis removal.

Secondary

MeasureTime frameDescription
Adverse device effects3 to 5 days after surgeryCollection of adverse device effects by the investigator on the retina, on the cornea, on the posterior capsula and other adverse device events
Adverse events3 to 5 days post-surgery;Collection by the investigator of other adverse events
Ocular adverse events30 ± 10 days post-surgery.Collection by the investigator of ocular adverse events

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026