Can Imaging Techniques Contribute to the Proper Insertion of Double-lumen Tubes?

The Role of Imaging Techniques in Predicting Double-Lumen Tube Size and Positioning. Prospective Observational Study.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05133401
Enrollment
100
Registered
2021-11-24
Start date
2021-06-01
Completion date
2021-12-30
Last updated
2022-01-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Computed Tomography, Double-Lumen Tube, Ultrasonography

Brief summary

In thoracic surgery, one-lung ventilation using a double-lumen tube (DLT) is often performed to protect dependent lung and provide comfortable surgical conditions. However, serious complications and adverse events can be encountered during DLT placement. One of the most important steps to avoid these drawbacks is to choose the appropriate size of DLT. The width of the trachea can be measured by using different imaging methods such as computed tomography (CT) and ultrasonography (US) to predict the appropriate DLT size. CT can also contribute to the proper placement of DLT by giving us the length of the trachea and main bronchi. In this study, we hypothesized that the size of the DLT can be determined more accurately by measuring the trachea diameter by using US and CT before DLT intubation. At the same time, we aimed to determine whether the evaluation of tracheobronchial anatomy with CT would contribute to the placement of DLT at a more appropriate level.

Interventions

DEVICEUltrasound-guided tracheal width measurement

Ultrasound measurements will be made with a 5-10 MegaHertz linear probe positioned in the horizontal plane at the midline of the anterior neck. After identifying the vocal cords as paired hyperechoic linear structures, the probe was moved caudally to visualize the cricoid arch. The transverse air column diameter was measured at the lower border of the cricoid cartilage.

Sponsors

Atatürk Chest Diseases and Chest Surgery Training and Research Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Patients who will undergo elective thoracotomy or video-assisted thoracic surgery with general anesthesia with DLT intubation * BMI 18 - 35 kg/m2 * Age 18 - 80 years old

Exclusion criteria

* Mallampati score 3 and 4 * History of tracheostomy, tracheal deviation, or distortion * Emergency surgery

Design outcomes

Primary

MeasureTime frameDescription
The measurement of the trachea diameter with ultrasound determines the size of the double-lumen tube to be used.1 hourAfter measuring the diameter of the trachea with ultrasound, the doctor will determine the double-lumen tube to be used according to the ultrasound measurement. Another experienced anesthesiologist, unaware of this result, will insert the double-lumen tube that he has determined with the conventional method.
The measurement of the trachea diameter by computerized tomography determines the size of the double-lumen tube is used.1 hourAfter measuring the diameter of the trachea with computerized tomography, the doctor will determine the double-lumen tube to be used according to the computerized tomography measurement. Another experienced anesthesiologist, unaware of this result, will insert the double-lumen tube that he has determined with the conventional method.
The measurement of the tracheal and main bronchi length and main bronchi diameter by computerized tomography in determining the size of the double-lumen tube and proper positioning of the double-lumen tube.1 hourThe correlation of predicted and used DLT size. In addition, the correlation between DLT malposition rate and trachea and main bronchi length and main bronchi diameter measured by imaging methods.

Secondary

MeasureTime frameDescription
Complications related to double-lumen tube intubation1 dayEvaluation of trauma, bleeding, sore throat and hoarseness in the airways due to double-lumen tube intubation.

Countries

Turkey (Türkiye)

Outcome results

None listed