Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.

The Purpose of This Research is to Assess Vivity Toric IOL Rotational Stability at the End of Surgery, Post op 1 Day, Post op 1 Week and Post op 4 Weeks. Participants in This Research Study Are 45 Years of Age or Older and Have Planned Implantation in at Least One Eye With an Acrysof IQ Vivity Extended Vision Toric IOL.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05119127
Enrollment
35
Registered
2021-11-12
Start date
2020-09-30
Completion date
2021-08-19
Last updated
2021-11-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Keywords

Vivity, Cataract, Intraocular lens

Brief summary

The purpose of this research is to assess the rotational stability of the AcrySof IQ Vivity Extended Vision Toric IOL and Refractive Visual outcome.

Detailed description

Assessment of the rotational stability and Refractive Visual Outcome of the AcrySof IQ Vivity Extended Vision Toric IOL at the end of surgery, post op 1 day, post op 1 week and post op 4 weeks. Participants in this research study are 45 years of age or older and have planned implantation in at least one eye.

Interventions

DEVICEAlcon Vivity toric intra ocular lens

implanting vivity toric IOL to asses rotational stability. IOL is already FDA approved for implantation at time of cataract surger. Intervention is to assess rotational stability and visual outcome.

Sponsors

Alcon Research
CollaboratorINDUSTRY
Eric Rosenberg, D.O.,M.Sc.Eng.
CollaboratorUNKNOWN
Kevin Barber
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Study will include adults (45 years and older) who plan to have cataract extraction and subsequent implantation of AcrySof® IQ Vivity™Extended Vision Toric IOL in at least one eye. Approximately 40 eye will be screened to identify 35 qualified eyes. Within 40 days of screening, qualified subjects will receive cataract surgery followed by implantation of the AcrySof® IQ Vivity™Extended Vision Toric IOL at the surgery visit. If the second eye will participate in the study, subjects will receive the second eye cataract surgery within 60 days of the Screening visit 0. Four postoperative follow up visits are planned to occur at 1-2 days, 7-14 days, and 28-35 days for each enrolled eye. Subject participation in this study is expected to last up to 2 months, including a total of 5 study visits for subjects implanted in one eye and up to 9 visits for subjects implanted in both eyes. Upon completion of the 35 day follow up visit subjects will be exited from the study.

Eligibility

Sex/Gender
ALL
Age
45 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Subjects undergoing cataract extraction with intraocular lens implantation. * Age: 45 years and older. * Willing and able to comply with scheduled visits and other study procedures. * Subjects who require an IOL power in the range of +15.0 D to +25.0 D. * Subjects with regular corneal astigmatism that can be treated with T3-T5. * Have good ocular health, with no pathology that compromises visual acuity (Outside of residual refractive error and cataract) * Potential postoperative visual acuity of 0.2 logMAR/ETDRS (20/32 Snellen) or better in both eyes.

Exclusion criteria

* Glaucoma. * Clinically significant corneal dystrophy. * Previous corneal refractive surgery (i.e LASIK, PRK, RK) * Pupil abnormalities. * Concurrent infectious/non-infectious uveitis. * History of chronic intraocular inflammation. * Visually significant macular disease. * History of retinal detachment.

Design outcomes

Primary

MeasureTime frameDescription
Rotational stability of Vivity Toric IOL.Five monthsRotational stability of Vivity Toric IOL will be measured at post op 1 day, post op 1 week and post op 4 weeks.

Secondary

MeasureTime frameDescription
Percentage of eyes with residual refractive astigmatism, absolute residual astigmatism prediction error, and monocular distance and intermediate visual acuities.Five monthsPercentage of eyes with post op rotation of five degrees or less, absolute prediction of error ≤ 0.5 D, residual astigmatism ≤ 0.5 D, residual astigmatism 1.00 D. Monocular and Binocular UDVA, UIVA, UNVA, CDVA, DCIVA and DCNVA.

Countries

United States

Outcome results

None listed