Nova Max Creatinine and eGFR Meter System

Nova Max Creatinine and eGFR Meter System - Evaluation

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05118074
Enrollment
360
Registered
2021-11-11
Start date
2021-06-08
Completion date
2024-04-15
Last updated
2025-03-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Kidney Injury, Chronic Kidney Diseases

Keywords

eGFR, Creatinine, POCT

Brief summary

To assess the performance of the Nova Max Creatinine and eGFR assay in the hands of CLIA-Waived Point-of-Care users in at least three (3) distinct Point-of-Care clinical settings on venous, and capillary blood and compare the performance characteristics to a traceable laboratory reference method (the Siemens EXL creatinine determination). To assess the Ease of Use of the Nova Max Creatinine and eGFR Meter System in the hands of the intended CLIA-Waived Point-of-Care users.

Detailed description

This study is designed to evaluate the performance of the NM Meter when used by CLIAW operators in terms of both accuracy to an established reference method and precision. CLIAW operators will receive no training or prompting on how to use the NM Creatinine and eGFR Meter, operating only using the instructions found in printed labeling materials (IFU, QRG, packaging). In determining the accuracy of the device, subjects will be tested using the NM Creatinine and eGFR Meter alongside a central laboratory reference method and the results will be compared to one another. This portion of the study is referred to as Method Comparison. In determining the precision of the device, multiple creatinine determinations will be made with the NM Creatinine and eGFR meter using both stabilized control materials (testing over the course of 20 days) and venous whole blood specimens (tested over the course of a single day). The difference between the multiple test results will determine the device's level of precision. This portion of the study is referred to as Precision.

Interventions

DIAGNOSTIC_TESTCreatinine, eGFR

Compare diagnostic tests to reference methods

Sponsors

South Florida Research Organization
CollaboratorUNKNOWN
Charisma Medical and Research Center
CollaboratorUNKNOWN
Excellence Medical Research
CollaboratorUNKNOWN
Nova Biomedical
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Adult males or females (≥ 18 years of age) 2. CKD Stage 1 (healthy) 3. CKD Stages 2-4 4. Subjects willing and able to consent to participating in the study. 5. Subjects whose pre-screen creatinine and eGFR value, if performed, is deemed valuable to the study.

Exclusion criteria

1. Subjects unable to consent to participating in the study. 2. Subjects possessing a cognitive disorder or other condition, which, in the opinion of the investigator, would put the person at risk or seriously compromise the integrity of the study.

Design outcomes

Primary

MeasureTime frameDescription
Analytical verification of Nova Max creatinine and eGFR meter system - Creatinine comparison20 daysNova Max creatinine and eGFR meter system, a point of care testing instrument is as effective as a reference laboratory method for Creatinine blood results in mg/dL
Analytical verification of Nova Max creatinine and eGFR meter system - eGFR comparison20 daysNova Max creatinine and eGFR meter system, a point of care testing instrument is as effective as a reference laboratory method for eGFR blood results in mL/min/1.73 m\^2

Countries

United States

Outcome results

None listed