Skip to content

StatStrip Glucose/Ketone Meter System Ketone Evaluation

StatStrip Glucose/Ketone Meter System Ketone Evaluation

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05118061
Enrollment
173
Registered
2021-11-11
Start date
2022-05-25
Completion date
2022-08-03
Last updated
2022-09-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus, Ketosis, Diabetic

Keywords

Ketone

Brief summary

The Nova StatStrip Glucose / Ketone Meter System is a fast, simple, whole blood system that can be used to quantify both glucose and ketones using two distinct test strips. This Protocol will describe an evaluation of the system's Ketone performance only. Ketone testing methods that quantify beta-hydroxybutyrate (β-OHB), the predominant ketone body, are used for diagnosing and monitoring ketoacidosis, a life-threatening complication of hyperglycemia. The performance of the StatStrip Ketone test strip using the Nova StatStrip Glucose / Ketone Hospital Meter System on venous and capillary whole blood will be assessed.

Detailed description

The primary objectives of this study are: 1. To assess the performance of the StatStrip Ketone assay in the hands of CLIA-Waived Point-of-Care users in at least three (3) distinct Point-of-Care clinical settings on venous, and capillary blood and compare the performance characteristics to a traceable laboratory reference method. 2. To assess the Ease of Use of the StatStrip Glucose / Ketone Meter System in the hands of the intended CLIA-Waived Point-of-Care users. CLIA-Waived operators will be provided with all package-insert sheets, a Quick Reference Guide and Instructions for Use (IFU) Manual. No training, coaching, or prompting will be provided to the CLIA-Waived POC Users other than clarifying the protocol.

Interventions

DIAGNOSTIC_TESTKetone

compare diagnostic tests to reference methods

Sponsors

Ocean Wellness Center
CollaboratorUNKNOWN
Nova Biomedical
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Adult subjects (≥ 18 years old) with diabetes or suspected ketonemia. 2. Adult subjects (≥ 18 years old) that are healthy. 3. Subjects willing and able to consent to participating in the study. 4. Subjects whose pre-screen ketone value, if performed, is deemed valuable to the study.

Exclusion criteria

1. Subjects unable to consent to participating in the study. 2. Subjects possessing a cognitive disorder or other condition, which, in the opinion of the investigator, would put the person at risk or seriously compromise the integrity of the study.

Design outcomes

Primary

MeasureTime frameDescription
Analytical verification of StatStrip glucose/ketone meter system - ketone comparison20 daysStatStrip ketone meter system, a point of care testing instrument is as effective as a reference laboratory method for ketone results in mmol/L

Countries

Germany, United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026