Hearing Loss
Conditions
Brief summary
This study will evaluate the clinical benefit of a transmitter for contralateral routing of signals. The benefit will be evaluated in noisy environments regarding speech intelligibility when the CROS system is adjusted to different microphone settings. Additionally, data regarding overall system stability, crash reboot rate, sound quality and connectivity will be obtained over a period of time to validate the CROS system in combination with smartphone and accessories. This study is a confirmatory study.
Detailed description
Unilateral Hearing Loss (UHL) can be defined as any degree of permanent hearing loss on one ear with normal hearing in the opposite ear. Unilateral hearing loss can be debilitating associated with audiological, psychosocial and educational challenges. Audiological challenges include the reduced ability to localize sounds, reduced awareness on the unaidable side and difficulties hearing in noise or at a distance. One solution for unaidable UHL is Contralateral Routing of Signals (CROS) and Bilateral Contralateral routing of signals (BiCROS) using a so- called CROS transmitter together with a hearing aid. The rationale for this clinical investigation is to collect clinical data with a rechargeable CROS transmitter to evaluate the benefits of a BiCROS fitting compared to the alternative treatment option, the monaural hearing aid fitting, and to no treatment in noisy listening situations.
Interventions
Each participant will be fitted with the experimental CROS device on the poorer, unaidable ear and with a compatible hearing device on the other ear.
Each participant will be fitted with a hearing aid on the better hearing ear and no device on the poorer, unaidable ear. Monaural hearing aid fitting acts as control intervention.
No treatment, i.e. the participants are not fitted with a CROS device and/ or hearing aid. Unaided condition acts as control intervention.
Each participant will be fitted with the experimental CROS device on the poorer, unaidable ear and with a compatible device on the other ear. The difference to the BiCROS condition is the setup of the microphones in the CROS device and the compatible hearing device. This test condition is only tested for speech intelligibility in diffuse noise and acts as control intervention.
Sponsors
Study design
Eligibility
Inclusion criteria
* hearing impaired adults, with & w/o hearing aids (experiences) * good written and spoken (Swiss) German language skills * ability to fill in a questionnaire conscientiously * informed consent as documented by signature * asymmetric hearing loss: one unaidable ear (min. N6 hearing loss) / the other ear with N3 or N4 hearing loss * availability of Smartphone * availability of TV or Tablet * ability to operate and handle the investigational device * ability to describe listening impressions/experiences and the use of the hearing aid * Ability to produce a reliable hearing test result
Exclusion criteria
* Contraindications to the medical device: * aidable hearing loss on the intended CROS side * acute tinnitus (in either one ear and occurrence less than three months) * anatomical deformity of the CROS ear (e.g. absence of the auricle) * Known hypersensitivity or allergy to materials of the investigational device * any auricle deformities, that prevents secure placement of the (test) devices * no willingness to test the investigational device system * no willingness to test the investigational device system for at least 8h a day * Hint for psychological problems from investigators point of view * reported fluctuating hearing that could influence the test result * reported symptoms of vertigo and dizziness by participants
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Speech Intelligibility (SI) in noise (fix direction): BiCROS fitting vs. monaural hearing aid fitting | 2 weeks | The primary objective of this clinical investigation is to evaluate whether a BiCROS fitting (better ear fitted with a hearing device, unaidable ear supplied with a CROS device) improves speech intelligibility in noise compared to a monaural fitting (just the aidable ear is supplied by a hearing aid), for adults with an asymmetric hearing loss, measured with the Oldenburg Sentence Test (OLSA). Results of the speech test will be the SRT (speech recognition threshold) in dB SNR (signal to noise ratio). The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A). The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A). |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| SI in diffuse noise: BiCROS fitting vs. monaural fitting | 2 weeks | A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility by at least 1 dB SNR for 50% SRT in diffuse noise, compared to a monaural hearing aid fitting. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A). The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A). |
| SI in diffuse noise: BiCROS fitting vs. unaided | 2 weeks | A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility by at least 1 dB SNR for 50% SRT in diffuse noise, compared to an unaided condition. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A). The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A). |
| SI in diffuse noise: BiCROS vs. CROS baseline fitting | 2 weeks | A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility in diffuse noise compared with a CROS baseline fitting. CROS baseline means a fitting of an additional program with different hearing instrument microphone setup. The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A). The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A). |
| SI in diffuse noise: CROS baseline fitting vs. unaided | 2 weeks | A secondary objective of this clinical investigation is to evaluate whether a CROS baseline fitting improves speech intelligibility in diffuse noise compared with an unaided condition. The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A). The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A). |
| SI in diffuse noise: CROS baseline fitting vs. monaural fitting | 2 weeks | A secondary objective of this clinical investigation is to evaluate whether a CROS baseline fitting improves speech intelligibility in diffuse noise compared with a monaural fitting. The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A). The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A). |
| SI in noise (fix direction): BiCROS fitting vs. unaided | 2 week | A secondary objective of this clinical investigation is to evaluate whether a BiCROS fitting improves speech intelligibility in noise compared to an unaided condition, for adults with an asymmetric hearing loss, measured with the Oldenburg Sentence Test (OLSA). Results of the speech test will be the SRT (dB SNR). The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A). The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A). |
| Evaluation of Sound quality | 3 weeks | A secondary objective of this study is to evaluate the participant's satisfaction of the sound quality of the experimental CROS device by a subjective rating during a three-week home trial period. Scale: very unsatisfied- unsatisfied- neither nor- satisfied- very satisfied |
| Evaluation of System stability | 3 weeks | A secondary objective of this study is to evaluate the participant's satisfaction of the system stability of the experimental CROS device during a three-week home trial period. The participant shall report, if there are artefacts audible: never/ 1-2 times a week/ 3-6 times a week/ daily |
| Evaluation of streaming | 3 weeks | A secondary objective of this study is to evaluate the participant's satisfaction of the streaming sound quality of the experimental CROS device, by a subjective rating during a three-week home trial period. Scale: very unsatisfied- unsatisfied- neither nor- satisfied- very satisfied |
| Evaluation of listening effort | 3 weeks | A secondary objective is to evaluate the subjective listening effort in noise reported by the participant whilst wearing the experimental CROS device. Scale: not at all - slightly - somewhat - moderately - very - extremely |
| SP in diffuse noise: monaural fitting vs. unaided | 2 weeks | A secondary objective of this clinical investigation is to evaluate whether a monaural fitting improves speech intelligibility in diffuse noise compared with an unaided condition. The SI will be tested with the OLSA in diffuse noise. The target speaker will be presented from 0° azimuth and is adaptive (start level at 65dB (A). The noise will be presented on the better ear at an azimuth of 90° or 270° (depending on the site of the better ear), at a level of 70 dB (A). |
Countries
Switzerland