Cerebral Oxygenation
Conditions
Keywords
cerebral oxygenation, ventricular tachycardia ablation
Brief summary
It is aimed to examine the effect of the decrease in blood pressure that occurs during the ventricular tachycardia ablation process on cerebral oxygenation and awareness. Patient's age, cardiac measurements (ejection fraction-EF), basal vital values, procedure time (especially activation and pacing mapping), and localization of the arrhythmia, may affect the NIRS and BIS response to blood pressure drop. In addition to the effects of patients' demographic information, cardiac capacity and procedure time on NIRS and BIS values (downtrend and duration), correlations of these values with other monitoring parameters (ETCO2 and SpO2) intended to be displayed.
Interventions
NIRS: Near-infrared spectroscopy is a measurement technique that non-invasively and continuously monitors the balance between cerebral oxygen consumption and delivery. BIS: BIS is an electroencephalogram-derived parameter developed to monitor the hypnotic effects of anesthesia.
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients over the age of 18 * Patients who will undergo VT ablation * Patients who want to participate in the study
Exclusion criteria
* Patients whose baseline values could not be obtained before induction * Patients with severe neurological or psychiatric illness * Patients who do not want to participate in the study
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Near Infrared Spectrometer | perioperative (ventricular tachycardia ablation) | cerebral oxygenation |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Bispectral Index | perioperative (ventricular tachycardia ablation) | awareness |
Countries
Turkey (Türkiye)