Skip to content

Study of the Effectiveness of a Polymer Cerclage System Compared to Cerclages Used in Standard Care (CERCPMCF) )

Outcomes of Adjuvant Polymer Cerclage System OrthoLoop to Manage Prosthetic Rehabilitation, Per Prosthetic or Primary Femoral and Humeral Fractures. a Prospective , Multicentric, Simple Blind , Comparative, Non-inferiority Study, Compared to Cerclage Systems Used in Standard Care.

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05087667
Acronym
SERRE
Enrollment
202
Registered
2021-10-21
Start date
2022-03-08
Completion date
2028-12-31
Last updated
2025-03-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Femoral Fracture

Brief summary

The use of cerclage wiring in the management of long bone fractures is common. With the increase in the placement of total hip ans shoulder prostheses, the occurrence of peri-prosthetic hip an shoulder fractures is also increasing, notably due to an older population. Whether it is for a fracture on a native femur or humerus, or on a periprosthetic hip or shoulder fracture, the use of cerclage wiring is an adjuvant additional but not the main means to ensure stable osteosynthesis, allowing re-loading and early rehabilitation of patients. This method has demonstrated its ability to improve the fixation of this fracture type, associated with osteosynthesis or hip/shoulder prosthesis revision surgery. However, metal cerclage expose to a risk of metallosis which can compromise bone fusion, injury to neighboring soft parts causing pain and also injury to the surgical team when handling them. More recently, non-metallic cerclage have been developed and could overcome certain risks associated with metallic cerclage, while ensuring their bone fixing capacity and therefore bone consolidation. Indeed, non-metallic cerclage could withstand similar or even greater stresses than metallic cables, in particular concerning their resistance to rupture. The Sterile Self Locking Polymer Cerclage System named OrthoLoop is a polymer cerclage which has been developed and could be used in these indications. Thus, this study (SERRE) aims to investigate the clinical results and sequelae of adjuvant cerclage wires OrthoLoop Cerclage in the management of rehabilitation, per prosthetic or primary femoral or humeral fractures compared with cerclages system used in standard care. SERRE is a 36 months follow up study in two arms : * Experimental group: OrthoLoop cercalge * Control group: cerclages used in standard care After each surgery, the patient follow-up period is 36 months. with 4 planned consultation visits after surgery at 6-8 weeks, 3, 6 and 36 months, with collection and measurement of the endpoints. The main objective of this study is to assess the role of OrthoLoop cerclage of COUSIN Biotech in comparison with cerclages (metallic for the majority) used in standard care ; in the optimization of the consolidation of primary and periprosthetic femoral or humeral fractures, 6 months after surgery.

Interventions

DEVICEImplantation of Ortholoop cerclage

implantation of Sterile Self Locking Polymer Cerclage System named OrthoLoop to the patient and follow up for 36 months post-intervention

DEVICEImplantation of Cerclage used in current practice

implantation of Cerclage used in current practice to patients and follow up for 36 months post-intervention

Sponsors

Cousin Biotech
CollaboratorINDUSTRY
Quanta Medical
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Masking description

Single blinded study. The patient will be blinded from the randomization arm. As the procedure is performed under general anaesthesia, the patient will not be informed whether or not the Sterile Self Locking Polymer Cerclage System has been implanted as a result of the procedure.

Intervention model description

Cluster's randomization

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* patient with femoral or humeral fracture requiring the installation of one or more cerclage(s) and respecting at least one of the criteria below: * Primary femoral or humeral fractures (diaphyseal, metaphyseal, epiphyseal proximal or distal) with osteosynthesis by plate and screw or osteosynthesis by Intramedullary nailing associated with the installation of one or more cerclage(s) * Patients with traumatic fracture of femur or humerus that required prosthetic rehabilitation associated with the installation of one or more cerclage(s) * Peri-prosthetic fracture of the femur or humerus * Resumption of prosthesis (hip, knee, shoulder, elbow) requiring the installation of one or more cerclages * who underwent fixation with cerclage wiring (Sterile Self Locking Polymer Cerclage System or other cerclage systems used in standard care) * age ≥18 years * Who have given free, informed and written consent to participate in the study * Patient able to communicate in French * Patient affiliated to a social security system or entitled to a social security system

Exclusion criteria

* high-energy injury, * associated damage to other long bones, * fracture extension to the articular surface with displacement * Severe disease that could interfere with the study results or be life threatening * Patients with an infection * Allergy to any component of the medical products * Pregnant or breastfeeding women * Anticipated unavailability during the study * Participation in a clinical trial within 3 months prior to the inclusion visit. * Patient with linguistic or psychological incapacity to understand and sign the informed consent. * Patient deprived of liberty by administrative or judicial decision, or being under guardianship.

Design outcomes

Primary

MeasureTime frameDescription
Assess role of Polymer Cerclage System OrthoLoop of COUSIN Biotech in comparison with cerclages (metallic for the majority) used in standard care; in the optimization of the consolidation of primary and periprosthetic fractures of long bones6 months post-surgeryprimary endpoint will be success or failure 6 months after surgery: Success of Sterile Self Locking Polymer Cerclage System to optimize consolidation during 6 months post surgery is defined as: * the ability to walk full weight bearing without pain at the fracture site, or return to normal, painless mobility at the fracture site, * and radiographs showing signs of bony union with no rupture or migration of the cerclage. Rupture or cerclage migration or nonunion or need for revision of the implant before 6 months is considered as failure.

Secondary

MeasureTime frameDescription
Asses union time3, 6 and 36 months post-surgeryUnion time is defined as time from intervention until * For Femoral fracture: ability of patient to walk full weight bearing without pain at the fracture site and radiographs showing signs of bony union * For humeral fracture: The patient regained full mobility without pain at the fracture site.
Assess rupture and migration rate of the cerclage after surgery throughout the follow-up3, 6 and 36 months post-surgeryRupture and migration of the cerclage are confirmed on X Ray imaging.
Assess pain6-8 weeks,3, 6 and 36 months post-surgeryPain will be assessed using visual analog scale pain scores (VAS) from 0 to 100 (0 means no pain at all and 100 maximum pain) at each visit.
Assess consolidation rate during 6 months post surgery6 months post-surgeryConsolidation (or union) is defined as the ability to walk full weight bearing without pain or return to normal, painless mobility at the fracture site , and radiographs showing signs of bony union
Assess surgery characteristicsDuring surgery (at D0)Surgery characteristics are: Rupture of cerclage during the surgery (at time of implantation) Number of wire cerclages used implant used for osteosynthesis (nail or plate) Using of screw fixation operative time
Assess physicians satisfaction regarding the use of Sterile Self Locking Polymer Cerclage SystemDuring surgery (at D0)Physicians satisfaction regarding the use of Sterile Self Locking Polymer Cerclage System will be assessed on: Global satisfaction of the surgeon Ease of use Ancillaries (Cable Passer, Tensioner) : ease of use and lightweight Ease of tension control by the surgeon using tensioner Ease of tracking of the cerclage on radiography Resistance over time (at least until bone consolidation) Presentation (ease of unwinding, packaging)
To report the incidence of complications and their treatment, particularly with respect to the need of further surgeryDuring the whole study (up to 36 months)]Safety data during patients 36 months follow up are defined such as: Infection Neurovascular injury Allergic reaction Bone ischemia Irritation feeling

Countries

France

Contacts

Primary ContactMarc Saab, Dr
b.hill@quanta-medical.com+33 (0) 1 47 08 63 41

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026