Comfort Operative Ocular Light Study

Prospective Multicenter Randomized Controlled 1:1 Study Evaluating the Efficacy of a 3D Digital Operating Microscope Compared to Conventional Microscopes Microscopes on the Comfort and Subjective Visual Sensations of the Patients Related to the Microscope Light During Initial Cataract Surgery Under Topical Anesthesia Topical Anesthesia

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05085314
Acronym
COOL
Enrollment
134
Registered
2021-10-20
Start date
2021-11-18
Completion date
2022-06-01
Last updated
2022-07-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract

Keywords

Ngenuity 3D digital operating system

Brief summary

Digital 3D microscopes require less light and may be more comfortable for patients requiring cataract surgery under topical anesthesia compared to conventional microscopes. To date, no studies have evaluated the comfort and subjective visual sensations related to the light of the 3D digital microscope in cataract surgery patients. The purpose of this study is to evaluate the effectiveness of the Ngenuity 3D digital operating system (Alcon, Fort Worth, TX) compared to conventional microscopes on the comfort and subjective visual sensations related to of patients undergoing initial cataract surgery under topical anesthesia (pure or combined with intravenous sedation).

Detailed description

Patients will be recruited during the preoperative consultation where the indication for cataract surgery. The allocation of the management arm (3D digital microscope or conventional microscope) will be randomized in a stratified way on the center. Prior to his or her operative session, the surgeon will set up the microscope with his or her usual parameters. The light intensity will be measured at the beginning of the operating session with a calibrated light meter. The type of anesthesia (pure topical or associated with intravenous sedation), the duration of the operation, intraoperative complications (frequency and type), and the possible use of an anesthesiologist to inject additional intravenous anesthetic will be collected. Before the patient is discharged from the ambulatory surgical unit, the clinical study technician will ask the patient the 4 questions of the standardized questionnaire assessing comfort and subjective visual sensations related to the microscope light.

Interventions

PROCEDURENgenuity digital 3D microscope

Cataract surgery under topical anesthesia with the Ngenuity digital 3D microscope, Alcon, Fort Worth, TX

Cataract surgery under topical anesthesia with a conventional microscope

Sponsors

Alcon Research
CollaboratorINDUSTRY
Fondation Ophtalmologique Adolphe de Rothschild
Lead SponsorNETWORK

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Indication for a first surgery (= first eye to be operated) of cataract alone under topical anesthesia (pure or associated with intravenous sedation) * Express consent to participate in the study

Exclusion criteria

* Patient benefiting from a legal protection measure * Patient with comprehension problems or who does not understand French well * Pregnant or breastfeeding woman * Indication for another surgery on the operated side (e.g. vitrectomy combined with cataract surgery)

Design outcomes

Primary

MeasureTime frameDescription
Glare of patients related to the light of the microscope of the patientstwo hours maximum after surgeryPatient response to the question Were you dazzled by light during surgery? rated on a numerical scale from 0 (Not at all) to 10 (Yes, very much)

Countries

France

Outcome results

None listed