Electrochemistry Measurement of Skin Hydration Parameters

Pilot Study Assessing the Feasibility and Reliability of Measurements of Skin's Parameters Hydration by Electrochemistry

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05071456
Acronym
SKINBIOSENSE
Enrollment
60
Registered
2021-10-08
Start date
2021-10-15
Completion date
2021-12-16
Last updated
2021-10-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acne, Atopic Dermatitis, Skin Electrochemistry

Keywords

Electrochemistry, Squalene, NMF, Skin

Brief summary

To date measuring the effect of dermocosmetic products on the main identified factors of aging and alteration of the skin barrier is based on invasive and expensive experiments. Electrochemistry enables to measure a specific signal for a substance of interest e.g. Vitamin C using an surface contact with an electrode. Therefore, this study will evaluate the reliability and feasibility of measurements of skin's hydration parameters such as NMF and squalene using electrochemistry. These study will be made on three groups of individuals with different skin types: dry skin i.e. atopic dermatitis patients, oily skin i.e. acne skin and a control group of individual without facial dermatosis. Collects of parameters of interest will be made by using patch using electrochemistry (contact with an electrode and potentiostat to detect an electric signal) . It is a simple method that relies on a sensor / electrode pair that allows a study of the surface molecules of the skin. Application in the measurement of vitamin C in food products has already been validated. On a second hand, a collect by chromatography of the parameters of interest will be carried out in order to compare the new method with the reference method. This procedure has been developed via a procedure including collecting surface parameters using a patch an developping special electrodes and miniaturized detecting signal tool (potentiostat)

Interventions

OTHERCollects of skin's hydration

Collects of skin's hydration will be made by using patch using electrochemistry.

Sponsors

SYNELVIA
CollaboratorUNKNOWN
WIRED BEAUTY Technologies
CollaboratorUNKNOWN
Assistance Publique - Hôpitaux de Paris
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Intervention model description

This study will include sixty subjects separate into three groups of twenty subjects based on the skin disease: acne, atopic dermatitis and a group control. This is a study validating the feasibility of a measure collected by a tool at the prototype stage with a view to pre-industrialization. The following process is: Measurement by patches and sensors of substances of interest on 2 areas of the face separated by the midline (forehead / cheek). Collection on the skin surface by 2 swabs repeated on 2 areas

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
Yes

Inclusion criteria

* 18 ≤ Age ≤ 70 * Subjects with past history or follow-up for acne or rosacea stage I ou II, atopic dermatitis mild to moderate without immunosuppressive treatment * Subjects enabling to perform a one day visit at the hospital * Written consent according to local regulatory requirements * Affiliated to a social security scheme

Exclusion criteria

* Pregnant women or breastfeeding * Patient under guardianship or curatorship, legal protection or protection of justice * Participation in other interventional research on skin moisturizer

Design outcomes

Primary

MeasureTime frameDescription
Feasibility of collecting an electrochemical measure of skin hydration parameter (natural moisturizer factor electric signal) at two different sites of the face at T0 using patch and electrodeDay 0 or Day 1Feasibility of collecting an electrochemical measure of skin hydration parameter (natural moisturizer factor electric signal) at two different sites of the face at T0 using patch and electrode. Signal detection (mVolt) or not using a patch to collect skin surface parameter applied on an electrode to collect and electric signal.

Secondary

MeasureTime frameDescription
Validation of the measure process for different skin type e.g: dry, oily, normalDay 0 or Day 1Rate of failure by site or skin type, obtained measure mean and SD for all and regarding each group
Determine the correlation between electrochemistry measures or skin hydration (level of electrical signal mvolt ) and reference method: corneometry or chromatography.Day 0 or Day 1Those two methods are routinely used to asses skin hydration using a swab contact then migration in a chromatography column or use of sebumeter Correlation coefficient between level of electrochemical measure (signal) regarding skin types and measures issued from reference methodology (corneometry or chromatography)
Describe individuals' habits or daily routine for skin care using a questionnairemethodology (corneometry or chromatography)Day 0 or Day 1Descriptive statistics: smoke, sun exposure, moisturizer use

Countries

France

Contacts

Primary ContactTu Anh Duong, MD PhD
tu-anh.duong@aphp.fr01 49 09 44 29
Backup ContactDavid Schmitz
david.schmitz@aphp.fr01 49 81 36 32

Outcome results