Skip to content

The Impact of Optical Coherence Tomography on the Endovascular Treatment Planning of Femoropopliteal Disease

The Impact of Optical Coherence Tomography on the Decision-making Process of Endovascular Treatment of Femoropopliteal Disease

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05057637
Acronym
Optimo
Enrollment
25
Registered
2021-09-27
Start date
2022-03-09
Completion date
2027-04-30
Last updated
2026-01-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Femoropopliteal Stenosis

Keywords

optical coherence tomography, digital subtraction angiography, endovascular treatment planning

Brief summary

Rationale: Peripheral arterial disease is a severe clinical problem with an increasing prevalence, due to an ageing population. Endovascular treatment, usually using stents, is recommended for most lesions in the femoropopliteal tract. The patency of these stents is influenced by several factors, including stent sizing and stent positioning. Current procedural planning of femoropopliteal disease is primarily based on single-plane digital subtraction angiographies (DSA). This modality provides a 2-dimensional image of the vessel lumen, which may be suboptimal for stent sizing. It can therefore be difficult to choose the optimal stent position as minor lesions may be missed. Suboptimal treatment could result in unfavourable levels of wall shear stress causing the vessel wall to be more susceptible to neo-intimal hyperplasia ultimately causing restenosis and stent failure. Intravascular optical coherence tomography (OCT) is able to visualize the arterial wall with a micrometer resolution, which could result in better stent sizing. Furthermore, OCT is able to visualize different layers in the vessel wall and identify unhealthy areas, which may lead to a more optimal stent placement as unhealthy areas can be covered completely. Moreover, OCT provides detailed patient-specific geometries necessary to develop reliable computational fluid dynamics (CFD) models that simulate blood flow in stented arteries and calculate wall shear stresses, which could predict stent patency. Objective: To investigate in a clinical study how often the use of intravascular optical coherence tomography for femoropopliteal stenotic lesions leads to alterations in treatment planning before and after stent placement, in comparison to traditional digital subtraction angiography-based treatment planning. Study design: Exploratory observational study. Study population: 25 patients with femoropopliteal stenotic lesions who are treated with a Supera interwoven nitinol stent or Absolute nitinol stent. Main study parameters/endpoints: The percentage of procedures in which OCT changed the DSA-based treatment planning before and after stent placement to investigate the impact of OCT imaging on treatment planning.

Interventions

DEVICEOptical coherence tomography measurements

Optical coherence tomography measurements in femoropopliteal tract

Sponsors

University of Twente
CollaboratorOTHER
Abbott
CollaboratorINDUSTRY
Rijnstate Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Aged 18 years of older * Written informed consent * Scheduled endovascular treatment of femoropopliteal stenotic lesions with a Supera interwoven nitinol stent or Absolute nitinol stent * Clinically and hemodynamically stable

Exclusion criteria

* Occluded superficial femoral artery or popliteal artery * Superficial femoral artery and/or popliteal artery diameter larger than 6.5 mm * Severely impaired renal function (eGFR \< 30 ml/min), end stage renal disease * Cardiac insufficiency (NYHA 3-4) * Hypersensitivity to iodinated contrast media * BMI \> 25 and contralateral approach not possible * Minimal lumen diameter of target lesion \< 1.5 mm * Presence of a hemodynamically significant inflow stenosis in the aorto-iliac tract or the common femoral artery * Participating in another trial with an investigational drug or medical device concerning the femoropopliteal tract interfering with the current study * Life expectancy of less than 24 months * Women of child-bearing age not on active birth control * Legally incapable

Design outcomes

Primary

MeasureTime frameDescription
Changed treatment planning based on OCTImmediately following the procedureThe percentage of procedures in which the OCT changed the DSA-based treatment planning before and after stent placement to investigate the impact of OCT imaging on treatment planning.

Secondary

MeasureTime frameDescription
Presence of artefacts in CTA scan6-8 weeks after the procedureThe presence of artefacts will be used to determine the image quality of the CTA scan
Presence of artefacts in OCT scanImmediately following the procedureThe presence of artefacts will be used to determine the image quality of the OCT scan
Segmented vessel lumen based on CTA scanUp to 2 years after the procedureThe vessel lumen in the CTA scan will be segmented to obtain a patient-specific geometry.
Segmented vessel lumen based on OCT scanUp to 2 years after the procedureThe vessel lumen in the OCT scan will be segmented to obtain a patient-specific geometry.
Correlation CTA-based and OCT-based vessel lumen segmentationsUp to 2 years after the procedureThe obtained CTA-based segmentation will be compared to the OCT-based segmentation. The vessel radius along the blood vessel for both the CTA-based and OCT-based segmentation will be compared point-by-point after which the correlation beteen both segmentations will be obtained
Velocity streamlines obtained from CTA-based CFD simulationUp to 2 years after the procedureVelocity streamlines are calculated using a computational fluid dynamics model based on the CTA-based vessel lumen segmentation.
Velocity streamlines obtained from OCT-based CFD simulationUp to 2 years after the procedureVelocity streamlines are calculated using a computational fluid dynamics model based on the OCT-based vessel lumen segmentation.
Time averaged wall shear stress obtained from OCT-based CFD simulationUp to 2 years after the procedureThe second parameter calculated using the OCT-based CFD simulation is the time averaged wall shear stress. This is the wall shear stress averagerd over one heartbeat.
Late luminal lossUp to 2 years after the procedureDefined as the vessel diameter right after procedure minus the vessel diameter during follow-up
Correlation between late luminal loss and CTA-based CFDUp to 2 years after the procedureThe regions with late luminal loss will be compared to regions with disturbed velocity streamlines and low time averaged wall shear stress (\<0.4 Pa) calculated with the CTA-based CFD. This correlation shows how well the CTA-based CFD model can predict late luminal loss.
Correlation between late luminal loss and OCT-based CFDUp to 2 years after the procedureThe regions with late luminal loss will be compared to regions with disturbed velocity streamlines and low time averaged wall shear stress (\<0.4 Pa) calculated with the OCT-based CFD. This correlation shows how well the OCT-based CFD model can predict late luminal loss.
Time averaged wall shear stress obtained from CTA-based CFD simulationUp to 2 years after the procedureThe second parameter calculated using the CTA-based CFD simulation is the time averaged wall shear stress. This is the wall shear stress averagerd over one heartbeat.

Countries

Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026