Skip to content

The Use of Virtual Reality During Breast Ultrasound-Guided Biopsy Procedures

The Use of Virtual Reality During Breast Ultrasound-Guided Biopsy Procedures

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05042999
Acronym
VRBB
Enrollment
60
Registered
2021-09-13
Start date
2021-09-15
Completion date
2022-01-07
Last updated
2023-04-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast Neoplasm Female

Keywords

Virtual Reality, Pain, Anxiety, Ultrasound Guided Biopsy

Brief summary

To determine if a virtual reality simulation will reduce pain and anxiety in patients undergoing an ultrasound guided breast biopsy procedure.

Detailed description

Breast biopsies for patients with abnormal mammograms are required to identify cancerous tissue. Currently this procedure is done with or without a local anesthetic. Patients report anxiety regarding potentially having cancer and the possibility of cancer-related procedures. Different types of biopsies may have different pain and anxiety based on their duration and complexity. This research is designed to determine if VR simulated environment can reduce pain and anxiety. The aim is to study the efficacy of a virtual environment in reducing pain and procedural anxiety. It is intended for patients undergoing an ultrasound guided breast biopsy procedure that have had an abnormal mammogram. The overall aim is to discover an efficacious nonpharmacologic method to lower pain and anxiety during a standard of care procedure.

Interventions

Oculus Go is a standalone portable Virtual Reality device that enables the user to immerse in different virtual environments. Non pharmacological technique to reduce pain and anxiety during a procedure.

Sponsors

Clemson University
CollaboratorOTHER
Prisma Health-Upstate
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Informed consent is obtained from the patient * Females who are 18 years of age * Patient is scheduled for preoperative ultrasound guided breast biopsy procedure

Exclusion criteria

* Patient is scheduled for a stereotactic biopsy procedure * The patient has motion sickness * The patient has severe cognitive disabilities or language barriers that inhibit study form completion in English * The patient has a history of seizures or epilepsy * Refusal of patient to sign consent

Design outcomes

Primary

MeasureTime frameDescription
Subjective Pain Assessment: Visual Analog ScaleImmediate post-procedurePain Measured with the Visual Analog Scale. Visual Analogue Scale (VAS) is a measurement instrument that tries to measure a characteristic or attitude that is believed to range across a continuum of values and cannot easily be directly measured. The individual will score their pain level by circling a number 0 - 10 both pre-operative and post-operatively. The scale range includes 0-10 scales, with \< 2 =well controlled, 2 - 5: partly controlled, \> 5: uncontrolled.

Secondary

MeasureTime frameDescription
State-Trait Anxiety Inventory (STAI: Y-6 item)Immediate post-procedureThe State-Trait Anxiety Inventory uses a 4 point Likert scale to assess how much worry, tension or apprehension the subject experiences in his or her present circumstances (state anxiety) and how much anxiety represent a personality characteristic (trait anxiety). Items emphasize the frequency of particular symptoms (ranging from 1 = not at all to 4 = very much). The range of possible scores for form Y of the STAI varies from a minimum score of 20 to a maximum score of 80 on both the STAI-T and STAI-S subscales. STAI scores are commonly classified as no or low anxiety (20-37), moderate anxiety (38-44), and high anxiety (45-80).
Patient SatisfactionImmediate post-procedurePatients in both groups will be asked to rate their satisfaction with their procedures using a five point likert scale (ranging from 1 = definitely disagree to 5 = definitely agree).

Other

MeasureTime frameDescription
Heart RateImmediate post-procedureEmpatica E4 watch is a wearable device that collects real-time physiological data. This wristband is equipped with photoplethysmogram sensors for computing Heart Rate (HR). Heart rate will be reported in beats per minute (bpm).
Galvanic Skin ResponseImmediate post-procedureThe Empatica E4 watch is a wearable device that collects real-time physiological data. The photoplethysmogram skin electrodes from the watch will capture the Galvanic Skin Response (GSR), also named Electrodermal Activity (EDA) and Skin Conductance (SC) or the measure of the continuous variations in the electrical characteristics of the skin. GSR will be reported in units of micro-Siemens (μS).
TemperatureImmediate post-procedureEmpatica E4 watch is a wearable device that collects real-time physiological data. The photoplethysmogram sensor from the watch will measure temperature. Temperature will be reported in degrees Celsius.
Blood Volume Pulse SignalImmediate post-procedureEmpatica E4 watch is a wearable device that collects real-time physiological data. The photoplethysmogram sensor from the watch will measure variation of volume of arterial blood under the skin resulting from the heart cycle computing Blood Volume Pulse (BVP). Blood Volume Pulse will be measured in beats min-1.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026