Endotracheal Tube Cuff Inflation Pressure Varieties and Response to Education Among Anesthetists

Endotracheal Tube Cuff Inflation Pressure Varieties and Response to Education Among Anesthetists

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05034666
Enrollment
28
Registered
2021-09-05
Start date
2018-01-01
Completion date
2018-05-01
Last updated
2021-09-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Endotracheal Tube

Brief summary

Cuff pressure is essential in endotracheal tube management. Guidelines recommend a cuff pressure of 20 to 30 cm H2O. One study, for instance, found that cuff pressure exceeded 40 cm H2O in 40-to-90% of tested patients. This study will investigate the endotracheal ETT cuff inflation pressure applied by the participating anaesthetists, and their response after being informed about the pressure the participants will apply.

Detailed description

Although the increasing uses of different supraglottic devices as an alternative, the traditional endotracheal intubation is still considered the commonly used method for managing the airway of a generally anaesthetized patient. After passing the endotracheal tube through the larynx, the anaesthetist inflates the cuff or asks the anaesthesia technician to inflate it. How much air is injected into the cuff is not a major concern for almost all anaesthetists and they usually depend on palpating the external cuff tense to judge is it too much, accurate or not enough? Cuff pressure is essential in endotracheal tube management. Guidelines recommend a cuff pressure of 20 to 30 cm H2O. Inflation of the cuff of pressure more than 30 cm H2O can damage the tracheal mucosa by compromising capillary perfusion. When pressures are greater than 50 cm H2O, total obstruction of tracheal blood flow occurs. For long times, without any evidence-based data, it has been believed that well-trained anaesthetists are capable of determining proper ETT cuff pressures. It is presumed that anaesthetists can detect appropriate inflation pressure and overinflated ETT cuff by palpating the ETT pilot balloon. Adequacy of cuff inflation is conventionally determined by palpation of the external balloon. Previous studies suggest that this approach is unreliable. One study, for instance, found that cuff pressure exceeded 40 cm H2O in 40-to-90% of tested patients. However, increased awareness of over-inflation risks may have improved recent clinical practice. The aim of the work: This study will investigate the endotracheal cuff inflation pressure applied by the participating anaesthetists, and their response after being informed about the pressure the participants will apply. Material and Methods: Type of the study: Prospective controlled single-blind study. Settings: After obtaining approval by the Ethics Committee of the Suez Canal University Hospital, and written informed consent with an explanation regarding the purpose, effects, technique, and complications, all anaesthetists, working currently in the facility, are included.

Interventions

BEHAVIORALBefore the education program

Before applying the education program of the endotracheal cuff pressure inflation to the participating anaesthetists.

BEHAVIORALAfter the education program

After applying the education program of the endotracheal cuff pressure inflation to the participating anaesthetists.

Sponsors

Suez Canal University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SEQUENTIAL
Primary purpose
PREVENTION
Masking
SINGLE (Subject)

Masking description

the participants are not informed about the visit, and the investigator is measuring the ETT cuff pressure in the absence of the participant.

Intervention model description

anaesthetists of anaesthesia department on Suez canal university

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* anaesthetists * works at Suez canal university hospital * resident, registrar, or senior registrar

Exclusion criteria

* refusal to participate * who will not complete the 2 rounds 3 readings each

Design outcomes

Primary

MeasureTime frameDescription
accuracy in inflating the cuff of the endotracheal tubesimmediately after fixation of the endotracheal tube during general anaethesiaassessment of the Anesthetists' accuracy in inflating the cuff of the endotracheal tubes used to maintain the airway of generally anaesthetized patients the change following feedback.

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026