Skip to content

Evaluating Contact Lens Optics

Evaluating Contact Lens Optics

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT05028790
Enrollment
16
Registered
2021-08-31
Start date
2022-02-27
Completion date
2022-12-13
Last updated
2024-02-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Myopia

Brief summary

This study will evaluate changes in refractive error and visual performance between a single vision soft contact lens and multifocal soft contact lens

Interventions

Participants will wear a single vision soft contact lens during the study visit

Participants will wear a multifocal soft contact lens during the study visit

Sponsors

David A Berntsen, OD PhD
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
SINGLE (Subject)

Masking description

Participants were masked to the order in which they wore contact lenses

Eligibility

Sex/Gender
ALL
Age
18 Years to 39 Years
Healthy volunteers
No

Inclusion criteria

* Able to read and understand the informed consent document * 18 to 39 years of age (inclusive) * Best corrected visual acuity of 20/25 or better in the right eye * Refractive error from -1.00D to -6.00D with astigmatism less than or equal to -1.00D in the right eye (corneal plane)

Exclusion criteria

* Any ocular or systemic conditions affecting vision, refraction, or the ability to wear a soft contact lens * History of ocular trauma or surgery causing abnormal or distorted vision * Current Rigid Gas Permeable (RGP) contact lens wearers * Unwilling to have contact lens fit photographed * Pregnant and/or lactating females, by self-report

Design outcomes

Primary

MeasureTime frameDescription
Visual PerformanceThrough completion of study visit, an average of 2.5 hoursLow contrast visual acuity was measured for each participant while wearing each of the two lenses

Secondary

MeasureTime frameDescription
Spherical Equivalent Refractive Error On-axisThrough completion of study visit, an average of 2.5 hoursRefraction was measured after cycloplegia with two drops of 1% tropicamide hydrochloride. Spherical equivalent refractive error was then measured 3 times with an aberrometer and averaged.
Spherical Equivalent Refractive Error at 30 Degrees Temporal RetinaThrough completion of study visit, an average of 2.5 hoursCycloplegic spherical equivalent refractive error was measured 3 times with an aberrometer and averaged.
Spherical Equivalent Refractive Error at 20 Degrees Temporal RetinaThrough completion of study visit, an average of 2.5 hoursCycloplegic spherical equivalent refractive error was measured 3 times with an aberrometer and averaged.
Spherical Equivalent Refractive Error at 20 Degrees Nasal RetinaThrough completion of study visit, an average of 2.5 hoursCycloplegic spherical equivalent refractive error was measured 3 times with an aberrometer and averaged.
Spherical Equivalent Refractive Error at 30 Degrees Nasal RetinaThrough completion of study visit, an average of 2.5 hoursCycloplegic spherical equivalent refractive error was measured 3 times with an aberrometer and averaged.

Countries

United States

Participant flow

Participants by arm

ArmCount
Single Vision Soft Contact Lens First, Then Multifocal Soft Contact Lens
Participants wore the single vision soft contact lens first, then the multifocal soft contact lens
9
Multifocal Soft Contact Lens First, Then Single Vision Soft Contact Lens
Participants wore the multifocal soft contact lens first, then the single vision soft contact lens
7
Total16

Baseline characteristics

CharacteristicSingle Vision Soft Contact Lens First, Then Multifocal Soft Contact LensTotalMultifocal Soft Contact Lens First, Then Single Vision Soft Contact Lens
Age, Continuous25.11 years
STANDARD_DEVIATION 1.83
24.63 years
STANDARD_DEVIATION 1.63
24 years
STANDARD_DEVIATION 1.15
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants0 Participants0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
9 Participants16 Participants7 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
2 Participants5 Participants3 Participants
Race (NIH/OMB)
Black or African American
3 Participants3 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
4 Participants8 Participants4 Participants
Region of Enrollment
United States
9 Participants16 Participants7 Participants
Sex: Female, Male
Female
8 Participants14 Participants6 Participants
Sex: Female, Male
Male
1 Participants2 Participants1 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 90 / 7
other
Total, other adverse events
0 / 90 / 7
serious
Total, serious adverse events
0 / 90 / 7

Outcome results

Primary

Visual Performance

Low contrast visual acuity was measured for each participant while wearing each of the two lenses

Time frame: Through completion of study visit, an average of 2.5 hours

ArmMeasureValue (MEAN)Dispersion
Single Vision Contact LensVisual Performance0.23 logMARStandard Deviation 0.08
Multifocal Contact LensVisual Performance0.38 logMARStandard Deviation 0.12
Secondary

Spherical Equivalent Refractive Error at 20 Degrees Nasal Retina

Cycloplegic spherical equivalent refractive error was measured 3 times with an aberrometer and averaged.

Time frame: Through completion of study visit, an average of 2.5 hours

ArmMeasureValue (MEAN)Dispersion
Single Vision Contact LensSpherical Equivalent Refractive Error at 20 Degrees Nasal Retina0.67 DStandard Deviation 0.58
Multifocal Contact LensSpherical Equivalent Refractive Error at 20 Degrees Nasal Retina-0.17 DStandard Deviation 0.57
Secondary

Spherical Equivalent Refractive Error at 20 Degrees Temporal Retina

Cycloplegic spherical equivalent refractive error was measured 3 times with an aberrometer and averaged.

Time frame: Through completion of study visit, an average of 2.5 hours

ArmMeasureValue (MEAN)Dispersion
Single Vision Contact LensSpherical Equivalent Refractive Error at 20 Degrees Temporal Retina0.52 DStandard Deviation 0.68
Multifocal Contact LensSpherical Equivalent Refractive Error at 20 Degrees Temporal Retina-1.30 DStandard Deviation 0.44
Secondary

Spherical Equivalent Refractive Error at 30 Degrees Nasal Retina

Cycloplegic spherical equivalent refractive error was measured 3 times with an aberrometer and averaged.

Time frame: Through completion of study visit, an average of 2.5 hours

ArmMeasureValue (MEAN)Dispersion
Single Vision Contact LensSpherical Equivalent Refractive Error at 30 Degrees Nasal Retina0.77 DStandard Deviation 0.7
Multifocal Contact LensSpherical Equivalent Refractive Error at 30 Degrees Nasal Retina-0.75 DStandard Deviation 0.6
Secondary

Spherical Equivalent Refractive Error at 30 Degrees Temporal Retina

Cycloplegic spherical equivalent refractive error was measured 3 times with an aberrometer and averaged.

Time frame: Through completion of study visit, an average of 2.5 hours

ArmMeasureValue (MEAN)Dispersion
Single Vision Contact LensSpherical Equivalent Refractive Error at 30 Degrees Temporal Retina0.68 DStandard Deviation 1.03
Multifocal Contact LensSpherical Equivalent Refractive Error at 30 Degrees Temporal Retina-1.20 DStandard Deviation 1
Secondary

Spherical Equivalent Refractive Error On-axis

Refraction was measured after cycloplegia with two drops of 1% tropicamide hydrochloride. Spherical equivalent refractive error was then measured 3 times with an aberrometer and averaged.

Time frame: Through completion of study visit, an average of 2.5 hours

ArmMeasureValue (MEAN)Dispersion
Single Vision Contact LensSpherical Equivalent Refractive Error On-axis0.61 DStandard Deviation 0.46
Multifocal Contact LensSpherical Equivalent Refractive Error On-axis0.17 DStandard Deviation 0.44

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026