Comparison of Standard and Ultrawide Field Imaging Systems

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05022615
Acronym
COCO
Enrollment
51
Registered
2021-08-26
Start date
2021-09-29
Completion date
2023-03-07
Last updated
2023-05-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetic Retinopathy

Brief summary

The purpose of this study is to evaluate the quality of ocular images captured on 3 different cameras of patients with diabetic retinopathy. The study will determine whether diabetic retinopathy assessment is comparable between the cameras. The research is being done to see if a camera takes higher quality pictures over the other cameras. 60 participants will be enrolled into this study. Participants need to have diabetic eye disease. This is a one-time study visit that lasts approximately 1 hour.

Interventions

DIAGNOSTIC_TESTTopcon Camera

Standard 7 field imaging

DIAGNOSTIC_TESTOptos Camera

Ultrawide field imaging

DIAGNOSTIC_TESTClarus Camera

Ultrawide field imaging

Sponsors

University of Wisconsin, Madison
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* any race * Established diagnosis of diabetes. * Willing to participate as evidenced by signing the written informed consent.

Exclusion criteria

* Unable to tolerate ophthalmic imaging. * Ocular is media not sufficiently clear to obtain technically acceptable ultrawide field images. * History of panretinal laser photocoagulation or vitrectomy (history of anti-vascular endothelial growth factor treatment is not an

Design outcomes

Primary

MeasureTime frameDescription
Early Treatment Diabetic Retinopathy Study (ETDRS) Severity Level within the 7 standard fields of Clarus, Optos, and Standard 7 Field imaging and statistical comparison1 dayThe images captured within the 7 standard fields on each camera will be graded using the ETDRS severity scale. The total range of possible scores for severity level is from 10 (no DR) to 80 (PDR with vitreous hemorrhage); higher scores indicate increasing severity. Details of ETDRS severity scale: 10-No DR, 15-Probable DR, no MAs, 20-MAs only, 35-Mild NPDR, 43,47-Moderate NPDR, 53-Severe NPDR, 60-PDR status post scatter photocoagulation, 61,65,71-PDR, 80-PDR with vitreous hemorrhage, 90,95-Ungradable. ETDRS level agreement will be cross-tabulated and κ statistics calculated and assessed: \<0.20, poor; 0.21-0.40, fair; 0.41-0.60, moderate; 0.61-0.80, substantial; and 0.81-1.00, almost perfect strength of agreement. Unweighted κ will be used to avoid potential bias by weighting. Agreement will also be tested for each severity level and k statistics analyzed.
Number of Ungradable ETDRS Images within the 7 standard fields of Clarus, Optos, and Standard 7 Field imaging1 dayThe images captured within the 7 standard fields on each camera will be graded using the ETDRS severity scale. The proportion of ungradable images will be documented. On all tests, P \< 0.05 will be considered significant, and nonparametric testing will be applied where appropriate.

Secondary

MeasureTime frameDescription
Early Treatment Diabetic Retinopathy Study (ETDRS) Severity Level assessment of Clarus global, Optos global, and Standard 7 Field grading and statistical comparison1 dayThe images captured on each camera will be graded using the ETDRS severity scale. The total range of possible scores for severity level is from 10 (no DR) to 80 (PDR with vitreous hemorrhage); higher scores indicate increasing severity. Details of ETDRS severity scale: 10-No DR, 15-Probable DR, no MAs, 20-MAs only, 35-Mild NPDR, 43,47-Moderate NPDR, 53-Severe NPDR, 60-PDR status post scatter photocoagulation, 61,65,71-PDR, 80-PDR with vitreous hemorrhage, 90,95-Ungradable. ETDRS level agreement will be cross-tabulated and κ statistics calculated and assessed: \<0.20, poor; 0.21-0.40, fair; 0.41-0.60, moderate; 0.61-0.80, substantial; and 0.81-1.00, almost perfect strength of agreement. Unweighted κ will be used to avoid potential bias by weighting. Agreement will also be tested for each severity level and k statistics analyzed.
Number of Ungradable ETDRS Images within the Clarus global, Optos global, and Standard 7 Field grading1 dayThe images captured within the global fields of the Clarus and Optos cameras and the 7 standard field image will be graded using the ETDRS severity scale. The proportion of ungradable images will be documented. On all tests, P \< 0.05 will be considered significant, and nonparametric testing will be applied where appropriate.
Image quality assessment per image grader1 dayThe images captured on each camera for each participant will be assessed for quality using the Wisconsin Reading Center's 3-step confidence score. 1-High (image can be graded for both 7 field ETDRS and global severity level); 2-Adequate (image cannot be graded for global severity level); 3-Inadequate (image cannot be graded for ETDRS and global severity level).
Reason Image Quality is compromised per image grader1 dayIf Wisconsin Reading Center Confidence score of 2 or 3, a reason is selected (technical, patient, both patient and technical, unknown, or N/A). Eyes with photographs classified as ungradable will be excluded from agreement tables.

Countries

United States