Skip to content

A Prospective, Multi-center Clinical Trial for Evaluating the Effectiveness and Safety of Online Coronary Angiography-Derived Index of Microcirculatory Resistance (caIMR)

A Prospective, Multi-center Clinical Trial for Evaluating the Effectiveness and Safety of Coronary Angiography-Derived Index of Microcirculatory Resistance Measured Online by a Coronary Functional Measurement System

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT05009667
Acronym
Flash III
Enrollment
116
Registered
2021-08-17
Start date
2021-10-14
Completion date
2021-12-31
Last updated
2022-04-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Microvascular Dysfunction

Keywords

Hemodynamics, Computational fluid dynamics, Index of microcirculatory resistance, Fractional flow reserve, Angiography-derived IMR

Brief summary

More than 50% of patients with stable or unstable angina pectoris have no obstructive coronary arteries by angiographic visual estimation, in which coronary microvascular dysfunction (CMD) is one of the causes of myocardial ischemia and chest pain. A coronary angiography-derived index of microcirculatory resistance (caIMR) is proposed for physiological assessment of microvascular diseases in coronary circulation. The aim of the trial is to assess diagnostic performance of caIMR, using wire-derived index of microcirculatory resistance (IMR) as the reference standard.

Detailed description

More than 50% of patients with stable or unstable angina pectoris have no obstructive coronary arteries by angiographic visual estimation, in which coronary microvascular dysfunction (CMD) is one of the causes of myocardial ischemia and chest pain. Presently, the index of microcirculatory resistance (IMR) measured by the pressure wire is recognized as standard for evaluating coronary microcirculatory function. A coronary angiography-derived index of microcirculatory resistance (caIMR) is proposed for physiological assessment of microvascular diseases in coronary circulation without pressure wire, hyperemic agents, or thermodilution method. This study is a prospective, multi-center clinical trial. In the study, IMR (measured by pressure wire) will be used as a reference standard to evaluate the feasibility, accuracy and safety of caIMR measured by a non-invasive diagnosis system (FM21a) based on angiography images and aortic pressure wave. 116 patients eligible for inclusion criteria will be enrolled in the study. Both IMR and caIMR measurement will be performed in the same patient in a random order after angiography. The definitions of IMR and caIMR for coronary microcirculatory ischemia are IMR≥25 and caIMR≥25. The primary endpoint is the diagnostic accuracy of caIMR. The secondary endpoint is caIMR's sensitivity, specificity, positive predictive value, negative predictive value, ROC curve and AUC of caIMR diagnosis, and the diagnostic characteristics of caIMR at the vascular level.

Interventions

DEVICEAngiography-derived Index of Microcirculatory Resistance

caIMR will be measured by pressure sensors which are produced by Suzhou Rainmed Medical Technology Co., Ltd. caIMR is calculated based on angiography images and Hyperemic Pa estimated from resting Pa according to prespecified equation.

DEVICEPressure wire-based Index of Microcirculatory Resistance

IMR will be measured by thermodilution method with pressure wire and arterial physiological detector which are produced by St. Jude Medical. IMR = Pd ∙Tmn

Sponsors

RainMed Medical Group
CollaboratorINDUSTRY
Ge Junbo
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Patients aged 18 years and above, 80 years old and below, with no gender limitation; 2. Patients with stable or unstable angina or suspected myocardial ischemia; 3. Patients voluntarily participated in this clinical trial and signed an informed consent form; 4. Target coronary with \<50% diameter stenosis (DS%) by visual estimation.

Exclusion criteria

1. Patients with suspected acute myocardial infarction; 2. Patients with old myocardial infarction; 3. Patients with primary or secondary cardiomyopathy; 4. Patients with primary or secondary heart valve disease; 5. Patients with severe cardiac insufficiency and LVEF≤35%; 6. Patients with renal insufficiency (eGFR\<60ml/min (1.73m\^2)) or patients undergoing dialysis; 7. Patients who are allergic to iodine contrast agents, adenosine, and ATP; 8. Patients with severe organ disease or life expectancy less than 24 months; 9. Patients who are participating in other clinical studies of investigational drugs or devices and have not reached their primary endpoint; 10. The patient who has other conditions that are not suitable for clinical trials; 11. Patients with coronary artery involved in coronary fistula and myocardial bridge; 12. The contrast media is not filled, the blood vessels are overlapped, or the target blood vessel is severely distorted, and the lesion location cannot be fully exposed, or the image quality is poor and cannot be recognized; 13. Left main coronary artery disease and right coronary artery orifice disease; 14. After angiography, the investigator believes that the patient cannot tolerate any of the detection methods between caIMR and IMR; 15. The investigator believes that the patient is not suitable for clinical trials after angiography;

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic accuracyThrough study completion, an average of 7 months.To compare diagnostic accuracy of caIMR for coronary microvascular dysfunction with IMR as control.

Secondary

MeasureTime frameDescription
Sensitivity, specificity, positive predictive value, and negative predictive valueThrough study completion, an average of 7 months.To compare the diagnostic performance between caIMR and IMR in the patient level, with IMR as the reference standard.
ROC curve, and AUCThrough study completion, an average of 7 months.Using IMR as reference standard, draw the ROC curve of caIMR. The definition of ischemia is IMR≥25.
Diagnostic performance on the vessel levelThrough study completion, an average of 7 months.The diagnostic features of caIMR compared with IMR on the vessel level.

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 11, 2026