Liver Cirrhosis, Liver Fibroses
Conditions
Keywords
Liver fibrosis, Liver cirrhosis, Liver biopsy, Shear wave imaging, Dynamic liver scintigraphy
Brief summary
The study Competitive Accuracy of Radiological Imaging Compared to Liver Biopsy in Patients With Liver Fibrosis is designed to test the accuracy of non-interventional radiological imaging and compare its results with the gold standard liver biopsy. This is prospective non-randomized single patient group study.
Interventions
All patients were referred for 2D-SWE liver elastography and liver liver scintigraphy with 99mTc-mebrofenin prior to liver biopsy.
All patients were referred for 2D-SWE liver elastography and liver liver scintigraphy with 99mTc-mebrofenin prior to liver biopsy.
Sponsors
Study design
Eligibility
Inclusion criteria
* chronic liver disease * signed informed consent * liver biopsy indicated by treating gastroenterologist/infectologist
Exclusion criteria
* non-corrected blood coagulation tests * acute liver disease * age below 18 years or above 80 years * disagreement to participate in the study * pregnancy
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Ultrasound elastography comparison to histological examination of liver biopsy specimen | Baseline only | Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment. |
| Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen I | Baseline only | Dynamic liver scintigraphy with 99mTc-mebrofenin parameter liver clearance (%/min/m2) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment. |
| Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen II | Baseline only | Dynamic liver scintigraphy with 99mTc-mebrofenin parameter uptake time (min.) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment. |
| Dynamic liver scintigraphy with 99mTc-mebrofenin comparison to histological examination of liver biopsy specimen III | Baseline only | Dynamic liver scintigraphy with 99mTc-mebrofenin parameter liver excretion (30 min./peak ratio) is compared to histological examination of liver biopsy specimen at a single time point before initiating antiviral treatment. |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Comparison of radiological imaging tests between each other II | Baseline only | Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to tracer excretion measured by dynamic liver scintigraphy with 99mTc-mebrofenin. |
| Comparison of radiological imaging tests between each other III | Baseline only | Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to tracer uptake time measured by dynamic liver scintigraphy with 99mTc-mebrofenin. |
| Comparison of radiological imaging tests between each other I | Baseline only | Liver stiffness measured by ultrasound elastography (2D-SWE) in kPa is compared to liver clearance measured by dynamic liver scintigraphy with 99mTc-mebrofenin. |
Countries
Lithuania