Skip to content

Effects of Low Molecular Weight Heparin Therapy With Soft-Mist Inhaler for COVID-19 Induced Hypoxemia

Early Effects of Low Molecular Weight Heparin Therapy With Soft-Mist Inhaler for COVID-19 Induced Hypoxemia: A Phase IIb Trial

Status
Completed
Phases
Phase 2Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04990830
Enrollment
80
Registered
2021-08-05
Start date
2021-02-03
Completion date
2021-05-21
Last updated
2021-08-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

COVID-19 Acute Respiratory Distress Syndrome, Hypoxemia

Keywords

Heparin, Low Molecular Weight Heparin, Inhalation, Antiviral, Soft Mist Inhaler

Brief summary

This is an investigator initiated, single-center, open-label, Phase IIb clinical trial with 40 patients (for a total of 80 patients) to assess efficacy of Low molecular weight heparin using soft mist inhaler in the treatment of critically ill patients with COVID-19 (coronavirus disease of 2019) induced ARDS (acute respiratory distress syndrome). The patients will be assigned in a 1:1 ratio to receive standard treatment protocol plus inhaled Low molecular weight heparin. The primary objective is to determine the hypoxemia improvement on a 5-point clinical scale for COVID-19 induced ARDS patients.

Detailed description

Lungs are the major target organ of COVID-19, caused by the SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2). Multiple drug options have been evaluated for efficacy against worsening symptoms of COVID-19 patients. Low molecular weight heparin, known for its antiviral and anti-inflammatory effect, was determined to be applicable for ARDS-induced Hypoxemia. In cases of viral diseases that primarily targets the lungs, oral drugs and parenteral applications have shown to be insufficient due to low drug accumulation in the target organ site. An increase in drug dosage in order to achieve the necessary drug concentration leaves the patient with intolerable side effects. An inhalation delivery route of the drug would not only directly target the lungs but would also require less dosage. This is expected to increase patient tolerability and the efficacy of the treatment. Soft mist inhalers are advantageous above the other inhalation devices, for it reaches a higher retention rate in the lungs. Furthermore, the device to be used in this clinical study provides an enclosed system which decreases the risk of environmental contamination, thus is meant to protect healthcare professionals or to minimize associated contamination risks. This Phase-IIb clinical trial is to include 40 critically ill COVID-19 induced ARDS patients, that will receive Low molecular Weight Heparin via a soft mist inhaler at a dose of 4000 IU per administration, twice a day for 10 days in addition to the standard treatment determined by the Turkish Ministry of Health. A total of 80 patients will be enrolled, in which the drug receiving group will be assigned. The primary outcome of the clinical study is the improvement of ARDS induced hypoxemia on a 5-scale determination method at the end of the 10th day. The study inquires to perceive the early effects of inhaled Low molecular weight heparin on critically ill COVID-19 patients.

Interventions

DRUGInhaled Low molecular weight heparin

Application with Soft Mist Inhaler

DRUGStandard Treatment

Control Group

Sponsors

Istanbul University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Treatment Group - Control Group

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Positive reserve transcriptase polymerase chain reaction (RT-PCR) test of nasopharyngeal swab for COVID- 19, and pneumonia confirmed by a Computed Tomography (CT). * Negative reserve transcriptase polymerase chain reaction (RT-PCR) test of nasopharyngeal swab for COVID- 19, but radiological and biochemical examinations unambiguously suggest COVID-19, when other possible diagnoses were excluded.

Exclusion criteria

* Pregnancy * History of heparin and associated drug allergies.

Design outcomes

Primary

MeasureTime frameDescription
Change in clinical status on a 5-point clinical scale for hypoxemiaDays 1-10* Level 1: if the patient can breathe comfortably in the room air. * Level 2: if the peripheral oxygen saturation improves with an oxygen therapy up to 6 L/min via nasal cannula. * Level 3: If it can be improved with a 500 mL reservoir oxygen mask with 15 L/min oxygen treatment. * Level 4: If it can be improved with high flow oxygen therapy. * Level 5: If the intubation is the only choice.

Secondary

MeasureTime frameDescription
Improvement rate of the breathing statusDay 1 and Day 10Change in number of patients that were able to breath in room air will be compared on Day 1 and Day 10 (Comparison between the Treatment Group and Control Group)
Change in peripheral oxygen saturation (Sp02)Days 1-10A change in SpO2 levels in the duration of the study (SpO2 \< % 95)
Length of stayDays 1-10Number of patients administered to intensive care unit (ICU)
Overall survivalDays 1-10During or post-study follow up period

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026