Skip to content

Accuracy of 3D Printed Complete Dentures Using Two Impression Techniques: RCT

Retention of 3D Printed Bases Using Prefabricated Thermoplastic Trays and Conventional Custom Impression Trays: Randomized Controlled Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04982510
Enrollment
11
Registered
2021-07-29
Start date
2021-08-01
Completion date
2023-06-27
Last updated
2024-02-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Edentulism Nos

Keywords

digital dentures, definitive impression, thermoplastic trays, printed denture, 3D, rapid prototyping

Brief summary

the aim of this crossover randomized controlled clinical trial is comparing retention of 3D printed maxillary complete dentures produced from thermoplastic impression trays and conventional acrylic impression trays. The research hypothesis is that there is no difference in patient satisfaction and retention of dentures constructed from definitive impression using the conventional tray and the prefabricated thermoplastic tray

Interventions

3D printed complete denture

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
DOUBLE (Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
MALE
Age
No minimum to 69 Years
Healthy volunteers
Yes

Inclusion criteria

* Male edentulous patients. * Cooperative and highly motivated patients. * Patients with well or moderately developed ridges and healthy attached mucosa of appropriate thickness free from inflammation

Exclusion criteria

* Patients with recent extraction less than 3 months ago * Patients with Parkinson's disease * Patients with xerostomia. * Patients with allergy to resins. * Pathological changes of residual ridges. * Patient with sever undercuts, or irregular bony exostosis. * Patients with flabby and flat ridges. * Patients with medical or psychological conditions that hinder co-operation. * Patients with class II or III jaw relation.

Design outcomes

Primary

MeasureTime frameDescription
Maxillary complete denture base retention2 weeks after denture insertionA loop will be attached to each denture base at the position of geographic center using self cure acrylic resin and the retention will be measured by applying the forces perpendicular to the denture using Digital Force Meter Each base will be tested 3 times and the average will be calculated.

Secondary

MeasureTime frameDescription
Patient satisfaction2 weekspatient satisfaction data will be collected through questionnaire and graded by Visual analogue scale for both study arms

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026