Skip to content

Ultrasonography of Optic Nerve Sheath Diameter for Noninvasive Detection of Raised Intracranial Pressure: ORIENT Study

Ultrasonography of Optic Nerve Sheath Diameter for Noninvasive Detection of Raised Intracranial Pressure: a Chinese Multicenter Study

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04981548
Enrollment
1000
Registered
2021-07-29
Start date
2021-11-06
Completion date
2023-11-30
Last updated
2023-07-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ultrasonography

Keywords

optic nerve sheath diameter, intracranial pressure

Brief summary

This study aims to adopt a multi-center large sample size study to define (1) the normal range of Chinese ONSD; (2) ONSD diagnosis for patients with high intracranial pressure; (3) to analyze the correlation between ONSD and intracranial pressure.

Detailed description

The ONSD, transcranial Doppler parameters and baseline data of the normal intracranial pressure group and the enhanced intracranial pressure group (more than 200 mmH2O) .

Interventions

OTHERno intervention

no intervention

Sponsors

The First Hospital of Jilin University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

1. People requiring lumbar puncture testing due to brain trauma, intracranial infection, intracranial vascular disease, intracranial tumors, peripheral neuropathy for the raised intracranial pressure group. 2. Healthy people for the normal intracranial pressure group.

Exclusion criteria

1. eye diseases, such as eye trauma, eye tumors, optic neuritis, and glaucoma 2. People with poor temporal window penetration. 3. Patients who refuse to sign informed consent.

Design outcomes

Primary

MeasureTime frameDescription
The normal range of ONSD in healthy Chinese adults.2021.8-2022.8We will perform ONSD measurements with normal people by using ultrasound. We aim to establish the range for optic nerve sheath diameter (ONSD) in healthy Chinese adults. And the normal range of ONSD will be measured and reported.
determine the ONSD cut-off point for high intracranial pressure.2021.8-2022.8We will perform ONSD measurements with patients who was suspected high intracranial pressure rand enquiring lumbar puncture. We will analyze the correlation between ONSD and intracranial pressure. And ONSD cut-off point for evaluating high intracranial pressure will be reported.

Countries

China

Contacts

Primary ContactSibo Wang, PhD
wangsibo92@163.com15844008297

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026