The Effectiveness of Tidal Volume Challenge Incorporating Plethysmographic Variability Index in Predicting Fluid Responsiveness

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04978909
Enrollment
50
Registered
2021-07-27
Start date
2021-07-31
Completion date
2022-07-31
Last updated
2021-07-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Validation of PVI in Tidal Volume Challenge Test

Keywords

tidal volume challenge,Plethysmography variability index,Fluid responsiveness

Brief summary

Determine the ability of changes in Plethysmographic Variability Index during tidal volume challenge to predict fluid responsiveness

Detailed description

The change of Plethysmographic Variability Index after tidal volume challenge as a predictor of fluid responsiveness, confirmed with the change of SVV using Flotrac advance cardiac output monitor. To determine whether the patient is fluid responder, Fluid challenge will be performed afterwards to confirm the patient's fluid responsiveness. We also aim to calculate the least significant change for Plethysmographic Variability Index and Philips PPV system.

Interventions

None listed

Sponsors

National Taiwan University Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
20 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

Inclusion: Patients undergoing elective major surgery (estimated \> 2-hr) with general anesthesia and mechanical ventilation in supine position Exclusion: 1. BMI \< 18.5 or \>30 kg/m2 2. Pregnant patient 3. Allergy to starch solution 4. estimated glomerular filtration rate\< 60

Design outcomes

Primary

MeasureTime frameDescription
The predictive ability of change in Plethysmographic Variability Index after Tidal volume challenge to predict fluid responsiveness20 minutesThe change in value of Plethysmographic Variability Index after increasing VTE from 6 ml/kg to 8 ml/kg.

Secondary

MeasureTime frameDescription
Least significant change for Massimo PVI and Philips PPV20 minutesCalculate the least significant change for Massimo PVI and Philips PPV using data acquired from our electronic system