Skip to content

A Randomized Study of Intraocular Caliper-assisted Capsulotomy for Age-related Cataract Patients With Corneal Limbus Opacity

A Randomized Controlled Trial Comparing Intraocular Caliper-assisted Capsulotomy Versus Verion Navigation System-assisted Capsulotomy for Age-related Cataract With Corneal Limbus Opacity

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04977102
Enrollment
74
Registered
2021-07-26
Start date
2021-08-01
Completion date
2022-10-31
Last updated
2021-07-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract Extraction

Brief summary

The purpose of this study is to compare the accuracy of capsulotomy assisted by intraocular caliper and Verion navigation system in phacoemulsification surgery and postoperative visual quality for age-related cataract patients with corneal limbus opacity.

Detailed description

Continuous curvilinear capsulorhexis (CCC) is an important and technically challenging procedure in cataract surgery. Too large or too small capsulorhexis can increase the incidence of intraoperative and postoperative complications. In recent years, the image projection device Verion navigation system has been reported that it can improve the repeatability and accuracy of capsulorhexis via projecting a pre-set size ring to guide capsulorhexis. However, we found that for the patients with corneal geriatric ring, pterygium or limbal lesions leading to unclear limbal boundary, the projected capsulorhexis will deviate from the center, resulting in capsulorhexis is off center in clinical practice. Our self-developed intraocular caliper, which is modified on the conventional intraocular irrigation needle, can accurately measure the size of capsulorhexis, and mark the position and boundary of capsulorhexis on the lens anterior capsule to guide capsulorhexis, thus significantly improves the accuracy and centricity of capsulorhexis. The purpose of this study is to compare the centricity and accuracy of intraocular caliper-assisted capsulorhexis in phacoemulsification for age-related cataract patients with corneal limbus opacity with that of Verion projection navigation system.

Interventions

Intraocular caliper is a modified intraocular caliper with standard calibration on the rinse needle.

Verion Image Guided System (Alcon Laboratories, Inc.) is a digital image guidance system consisting of a diagnostic reference unit and a surgery pilot for intraoperative surgical assistance. The device can be used to align toric intraocular lens during surgery as well as support manual creation of a capsulorhexis with a predefined target diameter.

Sponsors

Zhongshan Ophthalmic Center, Sun Yat-sen University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
55 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Adults aged 55 to 80 years with age-related cataract with pterygium, Corneal geriatric ring, and corneal limbus opacity; * Pupil diameter ≥ 6.5mm after pupil dilation; * Lens nuclear opacity grading score (LOCS III) lower than 4.0.

Exclusion criteria

* Patients had previous intraocular surgery; * Patients with a diagnosed eye disease that may affect the functions of lens suspensory ligament such as previous ocular trauma, lens subluxation, pseudoexfoliation syndrome, retinal pigment degeneration; * Patients had other ocular diseases that impair visual function include optic neuropathy, uveitis, and tumor. * Refused to participate the study.

Design outcomes

Primary

MeasureTime frameDescription
Distance between pupil center and capsulorhexis centerDuring the surgeryThe primary outcome was the distance between pupil center and capsulorhexis center. Clear images of the edges of IOL and capsulorhexis were taken at the end of the operation, and Image J image analysis software is used to measure the distance between pupil center and capsulorhexis center with the diameter of IOL optical surface (6 mm) as the reference by two independently professional graders at the meantime.

Secondary

MeasureTime frameDescription
Ideal ratio of capsulorhexisDuring the surgeryIdeal capsulorhexis is defined as a centered and round capsulorhexis , which can cover the edge of IOL optical surface continuously for 360 degrees with a diameter between 5.0 to 5.5 mm.
Grades of capsulorhexis-IOL overlapDuring the surgeryThe capsulorhexis-IOL overlap of each patient was graded as 360-degree continuous overlap, 270\ 360-degree overlap, 180\ 270-degree overlap, 90\ 180-degree overlap, and \< 90-degree overlap.
Deviation of horizontal and vertical diameter of capsulorhexis from the target diameter (5.3 mm)During the surgeryMeasured by Image J image analysis software.
Horizontal and vertical diameter of capsulorhexisDuring the surgeryMeasured by Image J image analysis software.
Uncorrected and corrected visual acuityOne month after surgeryEvaluated with ETDRS visual acuity chart.
Intraocular lens decentrationOne month after surgeryMeasured by anterior segment OCT (CASIA2).
Intraocular aberrationsOne month after surgeryMeasured by OPD-SCAN III.
Distance between pupil center and capsulorhexis centerOne month after surgery
Intraocular lens tiltOne month after surgeryMeasured by anterior segment OCT (CASIA2).

Countries

China

Contacts

Primary ContactXiaoyun Chen, PhD
chenxiaoyun@gzzoc.com+86 13632343642

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026