Skip to content

Effect of Multifocal Intraocular Lens on Contrast Sensitivity in Primary Angle-Closure Patients

Effect of Multifocal Intraocular Lens on Contrast Sensitivity in Primary Angle-Closure Patients

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04972435
Enrollment
35
Registered
2021-07-22
Start date
2014-01-02
Completion date
2015-12-30
Last updated
2021-07-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Primary Angle Closure Glaucoma, Primary Angle Glaucoma Closure Suspect, Senile Cataract

Keywords

primary angle closure, primary angle closure glaucoma, cataract surgery, contrast sensitivity, intraocular lens

Brief summary

This prospective study included patients with primary angle-closure (PAC or primary angle-closure glaucoma (PACG) and visually significant cataract. Phacoemulsification with multifocal intraocular lens (MIOL) or monofocal IOL (mIOL) (patient preference) was performed. Collected data included best-corrected distant visual acuity (BCVA), intraocular pressure (IOP), anterior chamber depth (ACD), and contrast sensitivity (CS) measured at spatial frequency 1.5, 3.0, 6.0, 12.0, and 18.0 cycles per degree (CPD) preoperatively, and at 2-6 months postoperatively. Preoperative and postoperative parameters were compared to evaluate the effect of MIOL on CS in eyes with PAC or PACG.

Detailed description

This prospective non-randomized clinical study was conducted at the Department of Ophthalmology of the Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand during January 2014 to December 2015. The study protocol and informed consent procedures were both approved by our center's institutional review board (IRB) (approval number Si 384/2014). Each patient provided written informed consent prior to participation. Primary angle closure was defined as an eye with invisible non-pigmented trabecular meshwork greater than 180 degrees and evidence of peripheral anterior synechiae on gonioscopy without glaucomatous optic disc appearance, glaucomatous pattern visual field damage, or history of increased IOP. Primary angle closure glaucoma was defined as an eye with invisible non-pigmented trabecular meshwork greater than 180 degrees on gonioscopy with glaucomatous optic damage (cup-to-disc ratio greater than 0.5 and/or localized neuro-retinal rim defect) and history of increased IOP raising. Patients with PACG must have been under good disease control, which was defined as IOP under 20 mmHg with 1 to 3 topical anti-glaucoma medications without deterioration of visual field, except generalized depression from cataract. Intra-ocular lens calculation was performed at the baseline visit using IOL Master. All patients received information about the advantages and disadvantages of MIOLs (Tecnis ZMB00 or Acrysof IQ Restore SN6AD1) and of mIOLs (Tecnis ZCB00 or Acrysof IQ SN60WF) before choosing the type of IOL that they individually preferred. Cataract surgery was performed by a single surgeon. Topical anesthesia was applied before standard phacoemulsification (2.2 mm temporal clear cornea incision and continuous curvilinear capsulorhexis) and IOL implantation into the capsular bag. Eyes with any intraoperative or postoperative complication were excluded. Data specific to uncorrected and best-corrected distant visual acuities (UCVA and BCVA) in logMar, auto-refraction, slit-lamp ophthalmoscopic examination, intraocular pressure (IOP) measurement with Goldmann applanation tonometry, contrast sensitivity (CS), anterior chamber depth (ACD), central corneal thickness (CCT), and axial length (AL) were collected on the preoperative screening day, and at the 2 to 6-month postoperative follow-up. CS was measured under normal room light (photopic) conditions to evaluate patient quality of vision during the performance of their daily activities using a Functional Vision Analyzer. This test produces sine-wave gratings of different spatial frequencies. The absolute values of distance CS were obtained at five spatial frequencies (1.5, 3, 6, 12, and 18 cycles per degree; CPD). Visante® AS-OCT was used to determine CCT and ACD. ACD was defined as the distance between the corneal endothelium and the anterior surface of the crystalline lens (preoperative) or iris plane (postoperative). Axial length was obtained using IOL Master. Comparisons of continuous data with normal distribution were made using Student's t-test for unpaired data, and using Mann-Whitney U test for non-normally distributed data. A p-value of less than 0.05 was defined as denoting statistical significance.

Interventions

DIAGNOSTIC_TESTContrast sensitivity

All subjects performed the contrast sensitivity measurement preoperatively and one time at 2 months postoperatively.

Sponsors

Siriraj Hospital
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Cataract patients with PAC or PACG who schedule for phacoemulsification with intraocular lens implantation. The patients must decide preoperatively to use multifocal IOL or monofocal IOL (patient preference) after receiving clear information about those 2 IOL models. Postoperatively, the contrast sensitivity (CS)will be measured with the same method. The postoperative CS were compared between groups.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Visually significant cataract patients aged \>18 years with PAC or PACG who underwent prophylaxis peripheral iridotomy at least 2 months prior to participation.

Exclusion criteria

* Patients with preexisting glaucomatous visual field defect, except generalized depression * Any other concurrent ocular diseases that could affect visual acuity, except cataract * History of ocular inflammation or ocular surgery, except laser peripheral iridotomy, which is a routine procedure for treating PAC/PACG

Design outcomes

Primary

MeasureTime frameDescription
Contrast sensitivityPreoperative (on screening day)Contrast sensitivity at partial frequency 1.5, 3.0, 6.0, 12.0, and 18.0 cycles per degree (CPD)

Secondary

MeasureTime frameDescription
Visual acuityPreoperative (on screening day)Visual acuity at distance in LogMar
Anterior chamber depthPreoperative (on screening day)Anterior chamber depth

Countries

Thailand

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026