Respiratory Measurement of Volume Change Using Accelerometer, Thermographic Camera Electrical Impedance Tomography and Motion Correlation Analysis Using Mattress Sensor in Healthy Individuals

Respiratory Measurement of Volume Change Using Accelerometer, Thermographic Camera Electrical Impedance Tomography and Motion Correlation Analysis Using Mattress Sensor in Healthy Individuals

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04964245
Enrollment
10
Registered
2021-07-16
Start date
2021-07-31
Completion date
2021-08-31
Last updated
2021-07-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy Adult

Keywords

Respiration, Tidal volume

Brief summary

Tidal volume can be the most important technical indicator for ventilation. Measuring the volume of breathing can be used as an indicator of how effective a patient's gas exchange is, and as a predictive indicator of the statue of respiratory disease indirectly. These Tidal volumes can be measured using spirometry and pneumotachograph, and the breathing volume and the rate of airflow can directly or indirectly evaluate the lung function of the patient. However, spirometry has limitations that patients who are difficult to measure, and that it is difficult to measure in bed. In this work, the movement of the thorax due to breathing is measured in a non-invasive manner (accelerometer, thermographic camera) and the accuracy is compared through changes in thoracic impedance obtained through Pulmovista 500. Furthermore, we would like to correlate the motion of the measured object through a mattress sensor.

Interventions

DEVICEMattress Sensor

the respiration parameters are measured using an Mattress pressure

DEVICEaccelometer

the respiration parameters are measured using an accelometer.

DEVICEthermographic camera

the respiration parameters are measured using an thermographic camera.

DEVICEElectrical Impedance Tomography

the respiration parameters are measured using an electrical impedance tomograhy.

Sponsors

Yonsei University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
19 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

1. over 19, under 50 years old and common BMI 2. non-smoking, person without cardiopulmonary disease.

Exclusion criteria

1\. smoking, cardiopulmonary, infectious diseases.

Design outcomes

Primary

MeasureTime frameDescription
The accuracy of respiration measurementsabout 20 minThe accuracy respiration measurements between thermographic camera, accelerometer, electrical impedance tomography, and mattress sensor.