Skip to content

Deep Learning of Knee Joint MRI Intelligent Detection

Deep Learning of Knee Joint MRI Intelligent Detection

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04958408
Enrollment
50000
Registered
2021-07-12
Start date
2021-01-01
Completion date
2022-05-15
Last updated
2021-07-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Knee Injuries

Brief summary

Knee joint is the most common part of sports injury. MRI is a powerful tool to diagnose knee joint injury. However, it takes a long time to read the film, needs a lot, and some hidden injuries have a high rate of missed diagnosis. The emerging deep learning technology can establish automatic recognition model through large samples. A large sample of knee joint MRI was collected retrospectively to train the deep learning model of knee joint MRI, and the sensitivity and specificity of the deep learning model were verified in multi center. Depending on the clinical needs, the deep learning model annotation system is established. A large number of knee MRI were obtained and labeled. According to the knee joint MRI training depth learning model, and iterative optimization, the final version is formed. Multi center validation was carried out. Continuous operation records and corresponding preoperative knee MRI were obtained from multiple hospitals. The sensitivity and specificity of the model were calculated with operation records as the gold standard. At the same time, an expert team composed of senior radiologists and sports medicine doctors was organized to read the films. The sensitivity and specificity of manual reading and AI reading were compared to prove the superiority of AI reading. This study can improve the efficiency of clinical MRI film reading, reduce the workload of doctors, improve the film reading level of grass-roots hospitals, promote the development of the discipline, and has good social benefits and market prospects.

Detailed description

The knee joint is the most common sports injury site in the human body, including ligament rupture, meniscus tear, cartilage lesions, and free body formation. Knee MRI has extremely high sensitivity and specificity in diagnosing knee diseases, especially its negative predictive value is close to 100%, and it is an effective means to assist clinicians in diagnosing knee diseases. However, there are many MRI sequences of the knee joint, and different diseases have different imaging effects on various sequences, and the types of knee joint diseases are complicated, so it takes a long time to evaluate the knee joint MRI. Due to the huge clinical demand for knee MRI, it has caused a great burden on radiology and sports medicine orthopedics. At the same time, for some special injuries of the knee joint, such as hidden meniscus tear, rupture of the anterior cross part and adhesion in place after rupture, local ligament injury, etc., the conclusions given by different readers are very different, and it is easy to miss the diagnosis. And the missed diagnosis seriously affects the prognosis of the knee joint, leading to the progression of arthritis. In addition, professional musculoskeletal system imaging experts have a long training cycle, and a large number of orthopedic doctors and radiologists in basic hospitals have limited reading skills for knee MRI, which limits the development of local sports medicine disciplines and the development of related diagnosis and treatment. The purpose of our research is to train the deep learning model of knee MRI through multi-center and large sample of knee MRI; Multi-center verification of the sensitivity and specificity of the knee MRI deep learning model, and compare the accuracy of the deep learning model and manual image reading.

Interventions

None listed

Sponsors

Huashan Hospital
CollaboratorOTHER
Shanghai Jiao Tong University Affiliated Sixth People's Hospital
CollaboratorOTHER
Chinese PLA General Hospital
CollaboratorOTHER
Inner Mongolia People's Hospital
CollaboratorOTHER
The First Affiliated Hospital of BaoTou Medical College
CollaboratorOTHER
Fourth Medical Center of PLA General Hospital
CollaboratorOTHER
The 8th medical center of chinese PLA general hospital
CollaboratorUNKNOWN
Hebei Medical University Third Hospital
CollaboratorOTHER
Tianjin Hospital
CollaboratorOTHER
Peking University Third Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL

Inclusion criteria

1. ACL-injured patients; 2. Follow-up of patients after ACL injury; 3. patients with genetic predisposition to ACL injury;

Exclusion criteria

1. Patients with joint injury caused by clear external forces; 2. Definitely have stroke, heart disease, epilepsy, cranial neurosurgery, migraine; 3. Have had a concussion or head injury in the past 6 months.

Design outcomes

Primary

MeasureTime frameDescription
Marking system design based on Magnetic Resonance Imaging(MRI)2021According to the development goals, combined with the performance of MRI and the structure of the model algorithm, the labeling rules and logic of knee MRI are determined. On this basis, a labeling system is designed, and different labeling tools are designed for a variety of lesions.
Data export and annotation2021Encrypt the MRI file and import it into the medical standard intelligent labeling system. Create a dedicated tagging account for each tagger to tag. Based on the previously marked image data, develop algorithms for segmenting different lesion areas.
Build a deep learning model2021According to the diagnostic logic, we select the coronal and sagittal images of the knee joint T2 MRI sequence for analysis. And choose the Resnext model that has been verified by a large number of ImageNet and other large data sets to extract the features of the coronal out-of-state images. After the multi-layer convolution operation, the key feature representation of the image is extracted. At the same time, in the process of feature extraction, the batch normalization module is used to perform feature transformation to highlight the most meaningful part of the feature.

Countries

China

Contacts

Primary ContactJia-Kuo Yu
yujiakuo@126.com01082267392
Backup ContactLin Lin
01082267392

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026