Anterior Cruciate Ligament Rupture
Conditions
Brief summary
The present study was aimed to investigate the kinematics differences between round-tunnel (ROT) and flat-tunnel (FLT) techniques and compare the influence to the anterior root of lateral meniscus (ARLM ) in anterior cruciate ligament (ACL) reconstruction when using hamstring graft.
Detailed description
Nine matched pairs of fresh-frozen cadaveric knees were evaluated for the kinematics of intact, ACL-sectioned, and either ROT or FLT reconstructed knees. The graft bundles for FLT technique were separately tensioned. A 6 degrees of freedom robotic system was used to assess knee laxity: (1) 134-N anterior tibial load at 0°, 15°, 30°, 60°, and 90°of knee flexion. (2) 10-Nm of valgus torque followed by 5-Nm of internal rotation torque simulates a pivot-shift test at 15°, 30°. (3) 5-Nm internal and external rotation torques at 0°, 15°, 30°, 60°, and 90°. (4) 10-Nm varus and valgus torques at 15°, 30°. Coverage of ACL tibial footprint and areas of ARLM attachment before and after reaming were measured using three-dimensional isotropic MRI scanning.
Interventions
reamed with round tunnel
reamed with flat tunnel
Sponsors
Study design
Intervention model description
Nine matched-paired fresh frozen human cadaveric knees were randomly distributed into two groups: Flat-tunnel (FLT) group and round-tunnel (ROT) group. One knee from each pair was reamed with flat tunnel, while the contralateral knee was reamed with round tunnel.
Eligibility
Inclusion criteria
* intact knee with no previous injures
Exclusion criteria
* those with ligamentous injury or a limited range of motion
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| simulated pivot-shift test | within 1 hour after surgery | 10-Nm of valgus torque followed by 5-Nm of internal rotation torque simulates a pivot-shift test at 15°, 30° of knee flexion |
| simulated KT-2000 arthrometer | within 1 hour after surgery | 134-N anterior tibial load simulates a KT-2000 arthrometer at 0°, 15°, 30°, 60°, and 90°of knee flexion |
| internal and external rotation | within 1 hour after surgery | 5-Nm internal and external rotation torques at 0°, 15°, 30°, 60°, and 90° of knee flexion |
| varus and valgus | within 1 hour after surgery | 10-Nm varus and valgus torques at 15°, 30°of knee flexion |
| average percentage of ACL tibial footprint coverage | within 1 hour after surgery | Coverage of ACL tibial footprint and areas of ARLM attachment before and after reaming were measured using three-dimensional isotropic MRI scanning post-operation |
Countries
China