Skip to content

Effect of Kinesio Tape on Motor Function in Subjects With ACL Rupture

Acute and Long Term Effect of Kinesio Tape on Motor Function, Proprioception and Balance in Subjects With ACL Rupture

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04954924
Enrollment
32
Registered
2021-07-08
Start date
2010-02-01
Completion date
2015-01-15
Last updated
2021-07-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

ACL Rupture, Rehabilitation

Brief summary

Thirty-two participants with ACL rupture were included in the study. All participants were divided in two groups - control and experimental. In the experimental group (n=16) participants received 4 weeks standardized physiotherapy and Kinesio tape, in the control group - standardized physiotherapy. Experimental measurements: Anthropometric measurements, pain intensity, static and dynamic balance, proprioception, knee flexion and extension muscle torque, level of activity

Interventions

OTHERstandardized physiotherapy program and Kinesio tape

Sponsors

Lithuanian Sports University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
18 Years to 35 Years
Healthy volunteers
No

Inclusion criteria

1. 18 - 35-year-old men; 2. a normal contralateral knee, 3. not a longer period than 3 months after ACL rupture.

Exclusion criteria

Participants were excluded if either knee had previously been injured or had undergone surgery, if they had concurrent osteoarthritis, if they had injured the posterior cruciate ligament, lateral collateral ligament, or posterolateral complex of the knee, or if they had a grade III tear of the medial collateral ligament.

Design outcomes

Primary

MeasureTime frameDescription
Static and dynamic balance4 weeksStatic and dynamic balance were measured by posturography method with a single piezoelectric force plate (KISTLER, Switzerland, Slimline System 9286) was used to measure postural sway activity.
Muscle torque4 weeksThe isometric and concentric torque of the knee extensor and flexor muscles of the non-injured and injured legs was measured using an isokinetic dynamometer (System 3; Biodex Medical Systems, Shirley, New York).
Joint position sense test4 weeksJoint position sense test was used to measure proprioceptive accuracy. Joint position sense for both legs was assessed for all subjects using the Biodex System Isokinetic Dynamometer 3 (Biodex Medical System Inc., Shirley, NY, USA).Subjects actively extended the knee from the resting position (90°flexion) to one of two test positions: 80° or 40° flexion at 0,5°/s velocity. Subjects were instructed to actively reproduce this criterion angle and to stop knee motion, via a thumb switch. No feedback was provided.

Secondary

MeasureTime frameDescription
The Lysholm scale4 weeksThe Lysholm scale does measure the domains of symptoms and complaints and does measure functioning in daily activities
The Tegner scale4 weeksThe Tegner scale measure the subjective functional activity
VAS scale4 weeksThe severity of pain was determined based on a numerical pain scale in which 0 symbolizes 'no pain' and 10 symbolizes 'maximum pain'

Countries

Lithuania

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026