Analysis of Influencing Factors of Gastric Preparation Quality for MCCG

Analysis of Influencing Factors of Gastric Preparation Quality for Magnetically Controlled Capsule Gastroscopy

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04933643
Enrollment
240
Registered
2021-06-22
Start date
2021-06-22
Completion date
2023-03-31
Last updated
2023-02-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Capsule Endoscopy

Keywords

Magnetically Controlled Capsule Gastroscopy, Influencing Factors, Gastric Preparation Quality

Brief summary

The invention of magnetically controlled capsule gastroscopy makes the movement of capsule endoscope in the body controllable. Endoscopic doctors can adjust the angle of capsule observation to examine gastric mucosa according to the need of examination. However, The presence of food residue, air bubbles, mucus and bile in the gastric cavity will affect the observation of gastric mucosa by capsule endoscopy. it will reduce the completion rate of capsule endoscopy, and even lead to misdiagnosis and missed diagnosis. The purpose of this study is to explore the factors affecting the quality of gastroscopy gastric environmental preparation of magnetically capsule.

Detailed description

Magnetically controlled capsule endoscopy is different from ordinary electronic gastroenteroscopy, it can not fill and clean the gastric cavity by water injection. The presence of food residue, air bubbles, mucus and bile in the gastric cavity will affect the observation of gastric mucosa by capsule endoscopy, reduce the completion rate of capsule endoscopy, and even lead to misdiagnosis and missed diagnosis, so the quality of MCCG gastric environmental preparation is an important factor limiting the accuracy of diagnosis of gastric lesions. We design the case report table by consulting the literature, and then collect patient information, and speculate the relevant influencing factors through the evaluation of the quality of gastric environmental preparation of the examination results. the ultimate goal is to reduce the missed diagnosis rate and misdiagnosis rate and the waste of clinical resources, to prepare the gastric environment more pertinently, and to provide certain guiding significance for the preparation of gastric environment in clinical magnetically controlled capsule endoscopy.

Interventions

None listed

Sponsors

Shandong University
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
Yes

Inclusion criteria

* patients aged 18-75 years old who intend to undergo magnetron capsule gastroscopy, regardless of gender * sign informed consent form

Exclusion criteria

* dysphagia, known or suspected gastrointestinal obstruction、stricture and fistula * patients with severe somatic diseases unable to complete examination * known active upper gastrointestinal bleeding * previous history of upper digestive tract or abdominal surgery to change * gastrointestinal anatomy * patients with cardiac pacemakers or implanted with other electronic medical * instruments and magnetic metal foreign bodies * pregnant women * claustrophobia or other mental disorders uncontrollable

Design outcomes

Primary

MeasureTime frameDescription
GCS score was used to evaluate the quality of gastric preparation24 monthsGCS score was used to evaluate the quality of gastric preparation. GCS was defined as the sum of the scores of six major anatomical markers of the stomach (heart, fundus, body, horn, sinus, and pylorus).A 4-point grading system was used to define cleanliness as excellent (no mucus and foam attachment :4 points);Good (there is a small amount of mucus and foam, but it does not affect the test: score 3 points);Average (with a fair amount of mucus or foam).Failure to complete a completely reliable examination :2 points);Poor (large amount of mucus or foam residue :1 point).The GCS is the total score for all six landmarks, ranging from 6 (completely unprepared) to 24 (perfect).Gastric preparation was defined as sufficient when GCS≥18 and insufficient when GCS\<18.
Questionnaire data were used to analyze the influencing factors24 monthsBefore the examination, the subjects were required to fill in a questionnaire about the influencing factors of the quality of stomach preparation. According to GCS, the subjects were divided into fully prepared group and inadequately prepared group. Finally, statistical analysis was used to find the influencing factors that had statistical significance with the quality of stomach preparation according to the questionnaire content.

Secondary

MeasureTime frameDescription
The number of positive lesions24 monthsThe positive lesions detected in this study refer to some focal lesions of the stomach, including polyps, ulcers, gastric varices, submucosal tumors and so on.The lesions were identified by physicians who had performed magnetic capsule gastroscopy in more than 400 cases.
Number of participants with treatment-related adverse events as assessed by CTCAE v5.024 monthsThe safety of MCCG includes the acceptability or adverse events of MCCG preparation and examination, which is defined as symptoms or signs such as drinking water, examination and swallowing capsules, such as monitoring abdominal distension, nausea or vomiting.we count the number of participants with treatment-related adverse events as assessed by CTCAE v5.0