Skip to content

Paired Assessment of Two Electromyographic Neuromuscular Monitors: Stimpod NMX450X Versus Datex-Ohmeda E-NMT

Paired Assessment of Two Electromyographic Neuromuscular Monitors: Stimpod NMX450X Versus Datex-Ohmeda E-NMT

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04931901
Enrollment
24
Registered
2021-06-18
Start date
2021-09-06
Completion date
2024-08-30
Last updated
2026-05-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Neuromuscular Manifestations

Brief summary

After anesthesia is induced, 2 EMG TOFF devices will be placed on the patients arms, one on the right arm, the other on the left. There will be a randomization per dominant hand and nondominant hand for the placing of the devices. The devices are the Stimpod NMX450X and the Datex-Ohmeda E-NMT.

Interventions

DEVICEEMG TOF device

Use of Stimpod NMX450X as an electromyographic neuromuscular monitor

Sponsors

Universitair Ziekenhuis Brussel
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
NONE

Intervention model description

Randomization per dominant and nondominant hand. So that there is an even share of number of patients with Stimpod NMX450X on dominant hand and Datex-Ohmeda E-NMT.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients (18 years old and above) * undergoing General Anaesthesia for noncardiac surgery requiring the use of a neuromuscular blocking agent.

Exclusion criteria

* Use of different types of neuromuscular blocking agents for the same patient within the same surgical procedure. * Known Neuromuscular diseases/syndromes judged to condition accurate neuromuscular monitoring. * Known acute or chronic hepatic disease.

Design outcomes

Primary

MeasureTime frameDescription
TOF-ratio (percentage)Up until 120 minutesTOF = Train-of-four. TOF-ratio is the ratio of the fourth muscle response to the first one. This is used to assess neuromuscular transmission. TOF% indicates fade in non-depolarizing block. We are comparing the calculated TOF ratio of the stimpod NMX to the datex-ohmeda E-NMT

Secondary

MeasureTime frameDescription
TOF-count (absolute number)Up until 120 minutes.TOF count is the actual number of detected muscle responses. The number that is used to calculate the percentage (TOF-ratio). When the TOF count drops below 4 responses, then the TOF% cannot be calculated. We are comparing the detected muscle responses of the stimpod NMX to the datex-ohmeda E-NMT

Countries

Belgium

Outcome results

None listed