Skip to content

EVALUATION OF THE CAPACITY OF A BIOMARKER BASED ON THE RAMAN ANALYSIS OF SYNOVIAL FLUID

EVALUATION OF THE CAPACITY OF A BIOMARKER BASED ON THE RAMAN ANALYSIS OF SYNOVIAL FLUID TO IDENTIFY ARTHROSIC PATIENTS RESPONDING TO VISCOSUPPLEMENTATION / VISCODIAG

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04931121
Acronym
VISCODIAG
Enrollment
40
Registered
2021-06-18
Start date
2018-08-28
Completion date
2021-08-27
Last updated
2021-06-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteoarthritis, Knee

Keywords

Osteoarthritis, Synovial fluid, Raman spectroscopy, Viscosupplementation, Biomarkers

Brief summary

Osteoarthritis (OA) is the most common joint disease in the world and induces major physical, psychological, societal and economic burdens. The management of osteoarthritis is complex. Viscosupplementation by local injection in the arthritic knee is a validated therapy used after failure of conventional analgesic treatments and non-pharmacological modalities. The size effect of this treatment is modest between 0.3 and 0.6. We do not currently have any predictive criteria for the effectiveness of this treatment. The procedure tested in this research is the characterization of synovial fluid (SF) by an in vitro Raman microspectroscopy technique. The results obtained will make it possible to compare the effectiveness of visco-supplementation with hyaluronic acid from the Hyalgan© trade according to classic criteria in the literature.

Detailed description

The proposed study consists in analysing the synovial fluid (SF) of patients obtained in conventional care that do not require new medical or nursing procedures. All care that patients will receive is routinely provided by physicians. There is no additional act of surveillance during the research. The follow-up medical visits are exactly the same as those offered to patients as part of their treatment, no additional visits are required. During the orthopedic consultation for HA injection, the initial WOMAC score as well as the PGAP and PASS scores will be measured. SF, usually considered as medical waste, will be collected during an arthrocentesis prior to the intra-articular injection of hyaluronic acid, freezed at -80°C and then sended to the IVTV platform at the Ecole Centrale de Lyon for DDRS Raman spectroscopy (LabRam HR 800, Horiba Jobin Yvon, Villeneuve d'Asq). Studied SYNODIAG biomarkers are dried drops parameters (surface) and Raman ratios according to the FR3059781 patent. At the 6-month follow-up visit, WOMAC, PGAP and PASS scores will be re-measured to determine the patient's responding/non-responding status. Finally, the objective of the study is to verify if there are significant differences between the Raman ratios and dried drops parameters of SF patients responding and non-responding to viscosupplementation.

Interventions

Synovial fluid is collected as part of a conventional injection of viscosupplement

Sponsors

University Hospital, Grenoble
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* If woman, not to be pregnant * Have radiographically diagnosed osteoarthritis of the knee that meets OARSI criteria for gonarthrosis (Altman and Gold, 2007; Kellgren and Lawrence, 1957). * Present a Kellgren-Lawrence radiographic score lower than 4 * Be treated with visco-supplementation after failure of conventional analgesic treatments and non-pharmacological modalities.

Exclusion criteria

* BMI greater than 28 * BMI lower than 15 * Kellgren-Lawrence score of 4 * Patients with no clinical symptoms of osteoarthritis * Patients treated with intra-articular steroid injection during follow-up * Patients who have had a synovectomy * Patients with severe systemic disease or with rheumatoid arthritis or other intercurrent rheumatic disease

Design outcomes

Primary

MeasureTime frameDescription
Biomarkers analysis based on Raman analysis of synovial fluid (SF) (SYNODIAG)6 monthsMeasuring the physicochemical index of the dried drop of SF (Raman ratios) between responding and non-responding patients.

Countries

France

Contacts

Primary ContactGRANGE Laurent
lgrange@chu-grenoble.fr+33 (0)4 76 76 51 36
Backup ContactGRUEL Réjane
rgruel@chu-grenoble.fr+33 (0)4 76 76 72.23

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026