Skip to content

Study of Music and Speech Perception in New Cochlear Implanted Subjects Using or Not a Tonotopy Based Fitting

Evaluation of the Impact of a Tonotopy Based Fitting on the Speech and Musical Perception in New Cochlear Implanted Subjects. Prospective Randomized Crossover Study.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04922619
Enrollment
26
Registered
2021-06-10
Start date
2021-06-10
Completion date
2021-09-30
Last updated
2021-10-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sensorineural Hearing Loss, Bilateral

Keywords

cochlear implant strategy, tonotopy based fitting

Brief summary

Main objective: Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the perception speech in noise. Secondary objectives: Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the perception of musical elements (contour test). Show the non inferiority of tonotopy based fitting strategy compared to default fitting strategy on the perception of speech elements in quiet. Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the qualitative preference for the listening of musical pieces.

Detailed description

Introduction: Cochlear implantation allows the rehabilitation of profound bilateral deafness, restoring speech perception and verbal communication when the traditional hearing aid no longer provides satisfactory hearing gain (Nimmons et al.). A cochlear implant includes an electrode array and its functioning is based on the principle of cochlear tonotopy: each electrode encodes a frequency spectrum according to its position in the cochlea (high frequencies are assigned to the basal electrodes and low frequencies to the apical electrodes). The cochlear implant thus breaks down the frequency spectrum into a number of frequency bands via bandpass filters corresponding to the number of electrodes in the implant. During the fitting these bands can be modified by the audiologist. The fitting software developed by the manufacturers proposed a default fitting with a lower limit between 100 and 250 Hz according to the brands and an upper limit of about 8500 Hz. The frequency bands assigned to each electrode follow a logarithmic scale with the high frequencies for the basal electrodes and the low frequencies for the apical electrodes. This distribution takes into account the number of active electrodes but does not take into account the anatomy and the natural cochlear tonotopy specific to each patient. Several studies have analyzed the anatomical variations of the cochlear dimensions: size of the cochlea and the ratio between the contact surfaces of the electrodes with the cochlea are variable from one patient to another (Stakhovskaya O et al., P. Pelliccia et al.). The insertion depth during surgery is also variable due to parameters related to the patients as well as to the operator, which seems to impact the understanding of speech in noise (Deep electrode insertion and sound coding in cochlear implants - Ingeborg Hochmair et al.). Mathematical algorithms have recently been developed to estimate the cochlear tonotopy of each patient from a CT scan assessment (Jiam et al., Sridhar et al.). CT imaging of the implanted ear combined with 3D reconstruction software, provides cochlear length measurements (Cochlear length determination using Cone Beam Computed Tomography in a clinical setting - Würfel et al .) Using this approach it is possible to measure the position of each electrode relative to the cochlear apex. These measurements are applied to the modified Greenwood equation to obtain the tonotopic frequency for each electrode and to determine for each patient a fitting based on the tonotopy of each electrode. Main objective: Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the perception speech in noise. Secondary objectives: Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the perception of musical elements (contour test). Show the non inferiority of tonotopy based fitting strategy compared to default fitting strategy on the perception of speech elements in quiet. Show the superiority of tonotopy based fitting strategy compared to default fitting strategy on the qualitative preference for the listening of musical pieces. Plan of the study: It is a prospective open monocentric randomized crossover study: measures will be done on the patient at 6 weeks and 12 weeks post-activation.

Interventions

DEVICEtonotopy based fitting then default fitting

Cochlear implant with default fitting then tonotopy based fitting

DEVICEdefault fitting then tonotopy based fitting

Cochlear implant with tonotopy based fitting then default fitting

Sponsors

MED-EL Elektromedizinische Geräte GesmbH
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
DOUBLE (Subject, Investigator)

Masking description

Double blind study: the patient and the investigator don't know the fitting.

Intervention model description

Two arms A and B: Arm A: patient's fitting with default fitting --\> 6 weeks use --\> tests and patient's fitting with tonotopy based fitting --\> 6 weeks use --\> tests Arm B: patient's fitting with tonotopy based fitting --\> 6 weeks use --\> tests and patient's fitting with default fitting --\> 6 weeks use --\> tests

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patient (\>= 18 years old) speaking French * Patient who fulfils the criteria for cochlear implantation

Exclusion criteria

* retro-cochlear pathology: auditory neuropathy, vestibular schwannoma * patient with residual hearing \< 60 dB HL at 250 Hz and \< 80 dB HL at 500 Hz

Design outcomes

Primary

MeasureTime frameDescription
speech recognition in noiseat 6 weeks post-activationThe speech recognition in noise is evaluated with syllabic list of 40 phonemes. The patient has to recognize 20 syllables. The phonemes are scored: each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%). Signal-noise-ratios of 9, 6, 3 and 0 dB will be tested with speech at 65 dB SPL.

Secondary

MeasureTime frameDescription
speech recognition in quietat 6 weeks post-activationThe speech recognition in quiet is evaluated with syllabic list of 40 phonemes. The patient has to recognize 20 syllables. The phonemes are scored: each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%).
Melodic contour testat 6 weeks post-activationThe test stimuli of the melodic contour test (Galvin et al. 2007) are melodic contours composed of 5 notes of equal duration whose frequencies correspond to musical intervals. Nine distinct musical patterns have to be identified by the patient. Each good answer is scored 1 yielding a total between 0 and 1 (or 0% and 100%).
Qualitative measure of musicat 6 weeks post-activationThe Gabrielsson scale (1988) is used to evaluate perceived sound quality as a multidimensional phenomenon, that is composed of a number of separate perceptual dimensions. Eight perceptual dimensions are evaluated: clarity, fullness, brightness vs dullness, hardness/sharpness vs softness, spaciousness, nearness, extraneous sound, loudness. Visual analog scales (VAS) are used for each dimension and the patient has to score the dimension on a 10 cm VAS (between 0 to 10).

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 5, 2026