Skip to content

Evaluation of Muscle Ischemia in Arterial Claudication (Tsingtao)

Evaluation de l'Ischemie Musculaire au Cours de l'Artériopathie Oblitérante Des Membres Inférieurs

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04911595
Acronym
Tsingtao
Enrollment
30
Registered
2021-06-03
Start date
2010-06-30
Completion date
2021-06-30
Last updated
2021-06-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Peripheral Arterial Disease

Brief summary

The goal is to compare the results observed in patients that had both an exercise oximetry and a thallium scintigraphy for lower limb claudication

Detailed description

On our routine pratice, patients suffering claudication (specifically atypical claudication or claudication of doubful vascular origin) have exercise oximetry to prove the vascular origin of pain. If still doubtful (inconsistency of pain and oximetry results) patients are referred for thallium scintigraphy. Our goal is to compare the results issued from these two test

Interventions

DIAGNOSTIC_TESTexercise oximetry

transcutaneous oxygen pressure is measured at the skin level on chest , buttocks and calves during a walking test 3.2 km\*:h 10% slope. From the test result the decrease from rest of oxygen pressure (DROP) index is calculated to estimate muscle ischemia

DIAGNOSTIC_TESTthallium scintigraphy

Muscle thallium fixation is measured immediately after a walking test 3.2 km\*:h 10% slope and at 4 hours after the test. From the test result the difference of late and early radioactivity is calculated at the buttock and calf level and normalized to total body radioactivity to estimate muscle ischemia

Sponsors

University Hospital, Angers
Lead SponsorOTHER_GOV

Study design

Observational model
CASE_ONLY
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Claudication suspected of arterial origin

Exclusion criteria

* missing endopoint value

Design outcomes

Primary

MeasureTime frameDescription
Correlation of thallium scintigraphy to oximetry results1 yearThe coefficient of correlation of DROP values to normalized late to early changes in radioactivity wil be calculated at the calf and buttock level

Countries

France

Contacts

Primary Contactpierre abraham, MD; PhD
piabraham@chu-angers.fr0241353689
Backup ContactMarine Mauboussin
marine.mauboussin@chu-angers.fr0668047430

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026