Skip to content

iCare® Home vs Goldmann Applanation Tonometry

iCare® Home vs Goldmann Applanation Tonometry: Agreement of the Methods and Comparison of Inter-observer Variation at a Tertiary Eye Centre

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04911387
Enrollment
61
Registered
2021-06-03
Start date
2020-04-01
Completion date
2020-10-31
Last updated
2021-06-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glaucoma, Ocular Hypertension, Open Angle Glaucoma, Pseudo Exfoliation Syndrome

Keywords

intraocular pressure, GAT, rebound tonometry, self-tonometry, iCare® Home

Brief summary

Self-tonometry with iCare Home is regularly performed at Sankt Erik's Eye Hospital since a few years back. The purpose of this study was to show that the eye pressure measurements made with iCare® Home by patients / relatives do not vary more than those made with the standard method, Goldman applanation tonometry (GAT), by different healthcare professionals. This will hopefully confirm the usefulness of self-tonometry.

Detailed description

Since a few years back, self-tonometry with iCare® Home has been available in glaucoma care. Sankt Erik's Eye Hospital was first in Sweden to use the new technology. Several studies have shown good agreement between measurements made by patients or healthcare professionals with iCare® Home and Goldman applanation tonometry (GAT). However, some researchers raise critical voices about the reliability of iCare® Home measurements because they can differ from GAT. GAT is considered the gold standard method of tonometry to which all other instruments are compared. But like all other methods, GAT has some limitations. At the clinic, the eye pressure is usually measured with GAT by different staff (ophthalmological nurses, opticians or doctors) from visit to visit. This can sometimes lead to pressure variations that may affect the follow-up of glaucoma patients. This raises the question of whether the difference between GAT and iCare® Home is statistically and clinically significant. The purpose of this study was to show that the eye pressure measurements made with iCare® Home by patients / relatives do not vary more than those made with the standard method GAT by different healthcare professionals. This will hopefully confirm the usefulness of self-tonometry.

Interventions

DEVICEIntraocular pressure measurments

Intraocular pressure measurements with iCare Home by participants (patients, volunteers) and healthcare staff as well as intraocular pressure measurements with GAT by participants different healthcare staff.

Sponsors

St. Erik Eye Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* primary open angle glaucoma (POAG) * pseudo-exfoliation glaucoma (PEX) * ocular hypertension (OHT) * no eye disease,

Exclusion criteria

* inability to perform measurements due to limited hand or arm mobility (eg rheumatism, tremor) * measurements outside the iCare® Home manufacturer's recommendations.

Design outcomes

Primary

MeasureTime frameDescription
Correlation between iCare® Home inter-user measurements12 monthsiCare® Home measurements made by participants (patients and volunteers) will be compared to iCare® Home measurements made by trainers' using the same device on the same occasion
Correlation between GAT measurements made by different healthcare personnel12 monthsGAT measurements made by iCare® Home trainers will be compared to GAT measurements made by other available healthcare personnel using a different device on the same occasion

Secondary

MeasureTime frameDescription
Agreement between iCare® Home tonometry and GAT12 monthsAgreement, repeatability and reliability of measurements made with iCare® Home tonometry and GAT will be assessed using Bland Altman analysis, ANOVA and interclass correlation coefficient (ICC).

Countries

Sweden

Outcome results

None listed