Temporary Transvenous Pacemaker Placement by Intracavitary Electrocardiogram Monitoring

Bedside Precise Temporary Transvenous Cardiac Pacemaker Placement by Intracavitary Electrocardiogram Monitoring

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04905199
Enrollment
60
Registered
2021-05-27
Start date
2021-03-25
Completion date
2022-01-31
Last updated
2021-11-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

AVB - Atrioventricular Block, Bradyarrhythmia, Bradycardia; Syncope, Brady-tachy Syndrome, Tachyarrhythmia, Tachycardia Bradycardia

Brief summary

Traditional temporary pacing catheter insertion by intracavitary electrocardiogram (IC-ECG) monitoring which only monitoring tip polar, the negative one. The investigators modified the technique by monitoring both negative and positive polar which will be precisely locating catheter tip and indicating the direction of the catheter tip. Extensively used temporary pacing catheter tip has two electrodes which are about 1 cm apart. Distal electrode is negative (-) and active, proximal electrode is positive (+) and indifferent. Investigators use both distal (-) and proximal (+) electrodes which can be attached to any two of the V leads, record as V(-) and V(+). Monitoring positions of the electrodes by V(-) and V(+) could provide more information about the tip position. Comparing the QRS amplitudes between V(-) and V(+), when catheter tip enters right ventricle chamber: the case of V(-) \> V(+) infers tip toward apex ventricle wall ; conversely, the case of V(-)\<V(+) indicates tip directs to outflow tract. The investigators hypothesis this monitoring will help precisely placement.

Interventions

PROCEDURETemporary transvenous cardiac pacing

Transvenous temporary pacemaker insertion by modified IC-ECG monitoring.

Sponsors

Hunan Provincial People's Hospital
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
14 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with indication of temporary transvenous pacing

Exclusion criteria

* Not applicate to IC-ECG monitoring.

Design outcomes

Primary

MeasureTime frameDescription
Pacer leads locationOne day.Satisfy location is in the apex of the right ventricle.
Catheter-related complicationsOne month.Pacing catheter related complications: tip dislocation caused pacemaker malfunction, myocardial injury, perforation, death.

Secondary

MeasureTime frameDescription
Other complicationsOne month.Complications not relate to pacing catheter.