Skip to content

Proof-of-concept of the Measurement of Lung Function Using the Relaxed Expiratory Occlusion Monitor (REOM)

Proof-of-concept of the Measurement of Lung Function Using the Relaxed Expiratory Occlusion Monitor (REOM)

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04903145
Enrollment
45
Registered
2021-05-26
Start date
2021-06-30
Completion date
2022-10-31
Last updated
2021-05-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Asthma in Children

Keywords

tremoflo, oscillometry, interrupter, asthma, REOM

Brief summary

(i) To validate the inversed occlusion technique by comparing the results of resistance obtained on the relaxed expiratory occlusion monitor (REOM) with the resistance obtained with respiratory oscillometry (OSC) measurements on the tremoflo® C-100 and (ii) explore (within-test and day-to-day) repeatability and responsiveness to change of this technique when used as home monitoring device in children with asthma.

Detailed description

Children will be evaluated for eligibility by telephone or videoconferencing. After eligibility and consent documented by email by parents and on a source document by the research assistant: 1. Children will receive by courier one new REOM unit, a tablet with charger, and related disposables (nose clips etc.), 2. At a videoconference planned at a mutually conveniently time with the child and their parents the following will be obtained; 1. Basic demographics (date of birth, age, sex, ethnicity, height, weight) and asthma morbidity and medications. 2. Training on the REOM unit measurement using a recorded instructions video, followed by hand-on use of the unit under remote observation. The Research Assistant will teach the parents and child in the REOM, namely on how to use the unit to measure resistance until it is mastered and reproducible, how to complete the brief daily questionnaire, and how upload data from the REOM to the tablet by Bluetooth. Confirmation of the validity and reproducibility of the technique will be obtained by review of the measurement output that will be sent by WIFI automatically from the tablet to a protected google drive (with the patient identified only by a code) accessible to the Coordinating Centre. 3. Briefly, a minimum of three (3) reproducible measurements of Reo on the REOM will be obtained in accordance to the following standardized procedures: the subjects will be asked to be comfortably seated upright, with the head slightly tilted upward at an angle of about 15 degrees from neutral position to prevent upper airway obstruction, with the cheeks tightly supported to prevent upper airway shunting. A nose clip will be worn to prevent nasal air leak. Subjects will be instructed to breathe normally in a single-use bacterial/viral respiratory filter connected to the mouthpiece of the REOM device. This manoeuvre will be repeated for a maximum of 6 trials to obtain a coefficient of variation (CV) ≤15% on at least 3 Reo measurements with visual remote inspection of the curves and results via Bluetooth connection by the research assistant. Each trial will last 20 to 30 seconds to obtain a minimum of 3 to 6 valid expirations per trial. The mean Reo of 3 reproducible measurements will be calculated at the peak (Reo1) and the low (Reo2) flow. 3. Once the technique is mastered, the child will be asked to: 1. Perform the REOM measurements once daily before receiving their asthma controller medication, ideally at the same time in the evening. 2. If the child requires a rapid beta-2 agonists because of symptoms, a before and after measurement will be obtained 30 minutes after the dose has been administered to document responsiveness to change once a day when sick. 3. Once a week, a short questionnaire including the cACT (or ACT for 12 years and older), a question about an acute care visit or use of rescue oral corticosteroids, and occurrence of any adverse event will be sent by text message or email (patient preference) throughout the study duration. 4. A research assistant will contact the family at 7±3 days, 14±3 days, and monthly thereafter or, if in case of problem with the equipment or interruption in REOM measurements/response to the weekly questionnaire. The study duration will be 4 months (to maximize the chance of an exacerbation).

Interventions

DIAGNOSTIC_TESTREOM

To compare data generated by the REOM device with data from the tremoflo C-100 device

Sponsors

MedTeq
CollaboratorINDUSTRY
Thorasys Thoracic Medical Systems Inc.
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
6 Years to 17 Years
Healthy volunteers
No

Inclusion criteria

1. Children aged between 6 and 17 years old 2. Adequate understanding of French or English 3. Asthma diagnosis confirmed by a physician 4. Poor asthma control in the past 6 months, that is, 1. an acute exacerbation requiring oral corticosteroids, or 2. an FEV1 \<80% of predicted, FEV1/FVC ratio below the lower limit of normal, or significant (≥12%) reversibility in FEV1, or 3. a total score \<20 on the child Asthma Control Test (ACT) for children aged ≤11 years or on the ACT for those aged ≥12 years).

Exclusion criteria

1. Inability to produce a good seal around the mouthpiece when previously tested with spirometry 2. Oscillometry or REOM, contra-indication to performing respiratory tests (e.g., facial trauma, chest pain, severe scoliosis) 3. Other reason interfering with respiratory testing.

Design outcomes

Primary

MeasureTime frameDescription
Resistance at low expiratory flow (Reo2)Over one weekUsing the REOM device the resistance (Reo2) at low expiratory flow will be calculated.
Respiratory resistance R5Over one weekUsing the tremoflo C-100 at 5 Hz to calculate the mean resistance during the patient's tidal breathing.
Expiratory resistance (R5exp)Over one weekUsing the tremoflo C-100 at 5 Hz to calculate resistance during the patient's exhalation.

Secondary

MeasureTime frameDescription
Respiratory resistance R19Over one weekUsing the tremoflo C-100 at 19 Hz to calculate the mean resistance during the patient's tidal breathing.
Expiratory resistance (R19exp)Over one weekUsing the tremoflo C-100 at 19 Hz to calculate resistance during the patient's exhalation.
Resistance at high expiratory flow (Reo1)Over one weekUsing the REOM device the resistance (Reo1) at high expiratory flow will be calculated.

Countries

Canada

Contacts

Primary ContactFrancine M Ducharme, MD
francine.m.ducharme@umontreal.ca514 345 4931

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026