New Method for Real-time Detection of Tissue Ischemia

New Method for Real-time Detection of Tissue Ischemia; IscAlert™ - Study

Status
Withdrawn
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04893473
Acronym
ISCALERT
Enrollment
0
Registered
2021-05-19
Start date
2021-05-14
Completion date
2021-05-14
Last updated
2021-05-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Biosensing Techniques, Blood Circulation Disorder, Carbon Dioxide, Ischemia

Keywords

Ischemia, Carbon dioxide, Biosensor, Musculature, Subcutaneous, Surgery, Orthopedic, Limb

Brief summary

This is a prospective, single arm, open, single centre clinical investigation designed to examine the feasibility and safety of the IscAlert™ device in patients scheduled for limb (arm/leg) surgery with tourniquet. IscAlert is measuring carbon dioxide in muscular and subcutaneous tissue. IscAlert is inserted into normal muscle and subcutaneous tissue in ischemic (operated limb with a tourniquet) and non-ischemic limb (non-operated limb).After the tourniquet is inflated, ischemia develops in the muscles and subcutaneous tissue. This will result in an increase in carbon dioxide, which will be detected by the sensor on the operated extremity, while the sensor on the non-operated will show normal values. After releasing the tourniquet cuff, the muscle will be reperfused and the carbon dioxide level is expected to decrease into normal levels. 50 number of patients will be enrolled to undergo the procedures. The IscAlert will be removed from the patient before the patient is discharged from the operating room, but in 25 of the patients, IscAlert™ will be inserted for 72 hours in the operated extremity after the end of surgery. After this, the sensors are removed.250 Devices is planned to be used in this clinical study.

Detailed description

This is a prospective, single arm, open, single centre clinical investigation designed to examine the feasibility and safety of the IscAlert™ device in patients scheduled for limb (arm/leg) surgery with tourniquet. 50 number of patients will be enrolled to undergo the procedures detailed in this clinical investigational plan using 250 devices. IscAlert is 0.8 mm in diameter and in vitro testing, shows stable and accurate measurements of tissue carbon dioxide . More than 100 animal experiments have been done with the sensor. The experiments have shown that the sensor detects ischemia (Increased carbon dioxide-measurements) in real time in the following organs and tissues: Brain, heart, liver, kidneys, pancreas, intestines, musculature and subcutaneous tissue. Sensitivity and specificity are close to 100%. The sensors are inserted into tissue by a split needle technique. The split needle is the size of a 3-gauge peripheral venous catheter. In animal studies, no complications have been detected when using the sensor. The IscAlert catheters are connected to an electronics unit that is fixed to the skin with an adhesive plaster outside the sterile area. The electrical signals are redirected to a personal computer approved for clinical use which continuously records tissue pressures of carbon dioxide . IscAlert is inserted into normal muscle and subcutaneous tissue proximal on the limb to be operated. The insertion is distal to the blood cuff, and far away from the surgery field. The insertion is done under sterile conditions in accordance with standard sterility criteria at the hospital. No pain during insertion will occur because of insertion is performed after anesthesia induction. Also, the insertion can be compared to an intramuscular injection. An identical IscAlert catheter is also inserted in the opposite extremity that is not to be operated and serves as a reference value. After the tourniquet is inflated, ischemia develops in the muscles and subcutaneous tissue. This will result in an increase in carbon dioxide, which will be detected by the sensor on the operated extremity, while the sensor on the non-operated will show normal values. After releasing the tourniquet cuff, the muscle will be reperfused and the carbon dioxide level is expected to decrease into normal levels within 15 - 45 minutes. In 25 patients, the biosensors will be removed from the patient before the patient is discharged from the operating room, but in 25 of the patients, IscAlert will be inserted for 72 hours in the operated extremity after the end of surgery to identify drifting of the sensors. After this, the sensors are removed. The primary objective is to evaluate the ability of the IscAlert device to measure carbon dioxide levels in ischemic and non-ischemic limb musculature and subcutaneous tissue in patients who experience orthopedic surgery with limb tourniquet and to assess the safety/efficacy using device IscAlert. Our hypotheses are: 1. The IscAlert device will be able to detect the presence of ischemia in muscle and subcutaneous tissue, whereby carbon dioxide levels, measured by IscAlert, will be higher in ischemic musculature than non-ischemic musculature in patients undergoing orthopedic limb surgery. 2. No clinically significant bleeding or infection will occur using IscAlert in this clinical study.

Interventions

DEVICEIscAlert

3 IscAlert sensors in the limb undergoing surgery and two control sensors in the opposite limb are inserted and carbon dioxide is measured continuously.

Sponsors

European Commission
CollaboratorOTHER
Oslo University Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
No

Inclusion criteria

* Patients must be scheduled for orthopedic limb surgery with planned use of tourniquet. * Subject must be ≥ 18 years * Able to give written signed informed consent * Tourniquet planned to be used \> 30 minutes

Exclusion criteria

* Sign of inflammation/infection, hematoma, and traumatized tissue at insertion site * Chronic use of anticoagulants

Design outcomes

Primary

MeasureTime frameDescription
Tissue carbon dioxide level72 hoursTissue carbon dioxide level (kPa) during insertion period

Secondary

MeasureTime frameDescription
Infection1 weekInfection from insertion site at the discretion of the investigator (yes or no)
Arterial carbon dioxide level2 hoursBlood gass analysis of carbon dioxide during surgery (kPa)
Arterial lactate level2 hoursBlood gass analysis of lactate during surgery (mmol/L)
Bleeding72 hoursAmount of blood from insertion site (ml)
Arterial Oxygen level2 hoursBlood gass analysis of Oxygen during surgery (Kpa)
Time of tourniquet2 hoursMinutes of inflated tourniquet during surgery (minutes)
End-tidal level of carbon dioxide2 hoursEnd-tidal level of carbon dioxide during anesthesia (kPa)
Arterial pH level2 hoursBlood gass analysis of pH during surgery