Clinical Value of Microvascular Ultrasonography in Real-time Differential Diagnosis of Thyrotoxic Patients

The Clinical Value of Microvascular Ultrasonography in Real-time Differential Diagnosis of Thyrotoxic Patients Between Hyperthyroidism and Thyroiditis

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04879173
Enrollment
50
Registered
2021-05-10
Start date
2020-10-14
Completion date
2022-10-31
Last updated
2021-05-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hyperthyroidism/Thyrotoxicosis

Brief summary

This study aims to verify the clinical value of thyroid ultrasound with microvascular flow imaging in thyrotoxic patients for differential diagnosis between hyperthyroidism and thyroiditis. We intend to use the RS85 Ultrasound device manufactured by Samsung Medison. Graves' disease and painless thyroiditis/subacute thyroiditis are the main cause of thyrotoxicosis. Precise discrimination between Graves' disease and painless thyroiditis/subacute thyroiditis is clinically very important in determining treatment methods, such as the prescription of antithyroid drugs. Primary endpoint was to verify the value of vascularity index, defined by Blood pixel in range of image / Total pixel in range of image .Seondary endpoint was to verify the superiority value of Microvascular flow imaging to discriminate thyrotoxicosis patients compared with Color doppler/ Power doppler ultrasound imaging and conventional ultrasound imaging.

Detailed description

Thyrotoxicosis refers to the appearance of various clinical symptoms or signs due to and excessive increase of thyroid hormone in the body. Graves' disease, which causes thyrotoxicosis, is one of the most common autoimmune diseases and is known to account for 0.5% of the population. Precise discrimination between Graves' disease and painless thyroiditis/subacute thyroiditis is clinically very important in determining treatment methods. The Microvascular flow imaging technology is expected to show higher sensitivity and accuracy than conventional color Doppler images in differentiating patients between Graves' disease and painless thyroiditis/subacute thyroiditis. We enrolled thyrotoxicosis patients in their initial presentation and used RS85 Ultrasound device manufactured by Samsung Medison to discriminate Graves' disease and painless thyroiditis/subacute thyroiditis. Power / Color doppler ultrasound imaging and conventional ultrasound imaging were used. Tranverse and longitudinal plane of the dominant lobe were selected for imaging. Doppler Adler's method was used to asscess vascularization. To assess the vascularity index, which is defined by Blood pixel in range of image / Total pixel in range of image, we selected the total tranverse plane of the thyroid as range of image.

Interventions

DEVICERS85 Ultrasound device

RS85 Ultrasound device manufactured by Samsung Medison

Sponsors

Dong Jun Lim
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Initial presentation with thyrotoxicosis

Exclusion criteria

* Past history of thyroidectomy * Factitious thyrotoxicosis * Unable for ultrasound

Design outcomes

Primary

MeasureTime frame
The optimal value of vascular index for differentiating the thyrotoxicosis reason12 months

Secondary

MeasureTime frame
The superiority value of Microvascular flow imaging12 months

Countries

South Korea

Contacts