OSA, Sleep Apnea
Conditions
Keywords
tomography, CBCT, Cone-beam computerized tomography, obstructive sleep apnea, airway volume, anterior-posterior measurement
Brief summary
The anatomical changes of the upper airway in a standing vs pseudo-supine position using Carestream Orthodontic Imaging (Volumetric) and Carestream Orthodontic Imaging module (AP measurements) of the patient's airway respectively, have been taken and the obtained results compared. In order to simulate the supine position, patients are placed in a supine position (180 degrees) in a dental exam chair, and asked to relax their lower jaw, allowing it to drop back, simulating their jaw falling back while sleeping. That bite is then captured with a Correct Plus™ Impression Material Superfast. Once the bite material hardens, it locks the bite in place. The patient then stands upright, and CBCT is taken standing while the jaw placement is still pseudo sleep-supine, supported by the bite material.
Interventions
In order to simulate the supine position, patients are placed in a supine position (180 degrees) in a dental exam chair, and asked to relax their lower jaw, allowing it to drop back, simulating their jaw falling back while sleeping. That bite is then captured with a Correct Plus™ Impression Material Superfast. Once the bite material hardens, it locks the bite in place. The patient then stands upright, and CBCT is taken standing while the jaw placement is still pseudo sleep-supine, supported by the bite material.
Sponsors
Study design
Eligibility
Inclusion criteria
* Participant must be a patient of Dr. Maryam Bakhtiyari's orthodontic practice * Participant must have a diagnosis of obstructive sleep apnea * Participant must have an invitation to join research study from Dr. Bakhtiyari
Exclusion criteria
* Participant cannot have a history of serious dental trauma
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| 3D volumetric airway measurement | through study completion, an average of 1 year | Investigators will measure and compare the 3D volumetric airway of the x-ray both with and without the pseudo-supine technique. This will be done on the computer using Carestream Orthodontic Imaging. |
| 2D Anterior-Posterior airway Measurement | through study completion, an average of 1 year | Investigators will measure and compare the 2D anterior-posterior airway of the x-ray both with and without the pseudo-supine technique. This will be done on the computer using the Carestream Orthodontic Imaging module. |
Countries
United States