Skip to content

Closed Loop Ventilation in Patients With COVID-19

Tidal Volumes Are Generated Automatically With Closed Loop Ventilation (INTELLIVENT ASV) is Safe in Patients With COVID-19

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT04873336
Enrollment
20
Registered
2021-05-05
Start date
2021-04-01
Completion date
2021-10-16
Last updated
2021-11-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

ARDS, Covid19

Keywords

Mechanical ventilation, Adaptive support ventilation, Transpulnonary pressure, Safety

Brief summary

Transpulmonary pressure may be higher in ARDS patients due to decreased respiratory system compliance. The hypothesis is that tidal volumes which are generated by Intellivent- Adaptive support ventilation (ASV) are safe range by transpulmonary pressure.

Detailed description

Patients will be enrolled in the first 24 hours of admission to the intensive care unit. APACHE-2 and SAPS-2 scores will be noted 24 hours after admission. COVID-19 pneumonia will be confirmed according to World Health Organization (WHO) interim guidance. Level of sedation will be monitored with Ramsey Sedation Scale. An esophageal balloon will be inserted in order to measure transpulmonary pressure(Ptp). The proper localization will be estimated according to ear-nose-xiphoid length. Localization of the balloon will be confirmed with the Baydur maneuver. Mojoli methods will be used to optimize the balloon filling volume. All patients will be mechanically ventilated under Intellivent-ASV mode. Initial settings will based on predicted body weight. 45 cmH2O will be determined as target end-tidal carbondiokside (ETCO2) but permissive hypercapnia will be allowed if necessary, to maintain lung protective ventilation. Safe pH value will be determined 7.25 independent from ETCO2 levels in patients who will be applied lung protective ventilation. FiO2 and PEEP will be set to maintain an SpO2 of 88-92%. Ptpinsp will be calculated by subtracting the esophageal pressure from the alveolar pressure measured during inspiratory pause maneuver. Targeted inspiratory transpulmonary pressure (Ptpinsp) was determined to be below 20 cmH2O. If Ptpinsp exceeds 20 cmH2O, minute-volume (MinVol) will be decreased by 10%. Minvol will be reduced below 100% if necessary, to achieve the target. Expiratory transpulmonary pressure (Ptpexp) will be calculated by subtracting the esophageal pressure from the alveolar pressure measured during expiratory pause maneuver. Targeted Ptpexp was determined from 0 to 3 cmH2O. If Ptpexp is below 0 cmH2O, PEEP will be increased until Ptpexp is positive. If Ptpexp exceed 3 mH2O, PEEP will be decreased until Ptpexp is below 3 mH2O. Transpulmonary pressure will be recorded at the beginning after that at least twice daily morning and evening visits. All measurement will be made in passive condition. Transpulmonary pressure measurement will continue until the patient is awake.

Interventions

A closed loop mechanical ventilation mode that adjusts oxygenization and ventilation automatically

Sponsors

Izmir Dr Suat Seren Chest Diseases and Surgery Education and Research Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* COVID-19 is confirmed with RT-PCR -\>18 years of age * Being intubated less than 24 hours * Not being planned to be extubated in 24 hours

Exclusion criteria

* COVID-19 is not confirmed with RT-PCR * Having an impaired hemodynamic status * Esophageal pathologies * Bronchopleural fistula

Design outcomes

Primary

MeasureTime frameDescription
Inspiratory Transpulmonary Pressure (Ptpins)The first 24 hours of mechanical ventilationPtpinsp will be measured with an inspiratory hold maneuver

Secondary

MeasureTime frameDescription
Expiratory Transpulmonary Pressure (Ptexp)The first 24 hours of mechanical ventilationPtpexp will be measured with an expiratory hold maneuver

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026