Electrical Impedance Tomography Measurements During Apnea Test in Patients With Suspected Brain Death

Electrical Impedance Tomography Measurements During Apnea Test in Patients With Suspected Brain Death

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04857242
Enrollment
10
Registered
2021-04-23
Start date
2021-04-01
Completion date
2023-04-13
Last updated
2024-02-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Brain Death

Keywords

Apnea testing, Electrical Impedance Tomography

Brief summary

Apnea testing is the final decisive examination in the strictly regulated process of brain death assessment. There is no standardized method found in the literature for apnea testing except for the inspection of possible spontaneous chest movements. In addition, the test itself lasts for several minutes leading to the collapse of the lungs. Electrical impedance tomography (EIT) is a non-invasive, real-time monitoring technique, which is suitable for detecting changes in lung volumes during ventilation. With its help, one can examine the spontaneous initiation of inspiration, the development of atelectasis and the reopening of collapsed regions by mechanical ventilation. Furthermore, the apnea test provides for analysing the effect of changes in pulmonary perfusion on impedance in the absence of noise generated by ventilation.

Detailed description

The aim of the study is to assess the eligibility of electrical impedance monitoring for the detection of possible spontaneous initiations of inspiration during apnea test in patients with suspected brain death. The study could contribute to the opening of new areas in the clinical use of the electrical impedance device. An additional aim is to observe the collapse and the reopening by recruitment manoeuvers of different pulmonary regions.

Interventions

DIAGNOSTIC_TESTApnea test, alveolar recruitment

Alveolar recruitment following the phase of apnea testing

Sponsors

Budapest University of Technology and Economics
CollaboratorOTHER
Hochschule Furtwangen University
CollaboratorOTHER
Szeged University
CollaboratorOTHER
Kiskunhalas Semmelweis Hospital the Teaching Hospital of the University of Szeged
Lead SponsorOTHER_GOV

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

* Patients with suspected brain death undergoing apnea test for detecting the absence of spontaneous breathing

Exclusion criteria

* age under 18 * pregnancy * pulmonectomy, lung resection in the past medical history * clinically end stage chronic obstructive pulmonary disease (COPD) * severe hemodynamic instability (vasopressor refractory shock) * severe bullous emphysema and/or spontaneous pneumothorax in the past medical history * chest drainage in situ due to pneumothorax and/or bronchopleural fistula

Design outcomes

Primary

MeasureTime frameDescription
detection of spontaneous inspiration20 minutesDetection of absolute changes in impedance using EIT during apnea test, which may refer to spontaneous initiations of inspiration

Secondary

MeasureTime frameDescription
Gas exchange20 minutesChange in arterial partial pressure of oxygen (PaO2) (mmHg) following alveolar recruitment performed after apnea testing
Dynamic compliance20 minutesChange in dynamic compliance (ml/cmH2O) following alveolar recruitment
End expiratory lung impedance20 minutesChange in end expiratory lung impedance (EELI) (%) following alveolar recruitment
Center of ventilation20 minutesChange in center of ventilation (%) following alveolar recruitment
Lung perfusion20 minutesChanges in lung perfusion during the apnea phase (%)

Countries

Hungary

Outcome results

None listed