Skip to content

Automatic Oxygen Titration in Patients After SARS-CoV-2 Infection

Effects of an Automatic Oxygen Titration vs. Constant Oxygen Flow Rates During Daily Activities in Patients After SARS-CoV-2 Infection

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04849598
Enrollment
15
Registered
2021-04-19
Start date
2021-04-13
Completion date
2021-08-27
Last updated
2021-11-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Post-COVID19

Keywords

post SARS-CoV-2 infection, long-term oxygen therapy, automatic oxygen-titration, hypoxemia

Brief summary

With the progression of the SARS-CoV-2 pandemic there's an increasing number of patients recovering from COVID19. Some of these patients still experience hypoxemia and therefore are still in need of a long-term oxygen therapy (LTOT), usually provided as a constant-flow. However, during a patient's daily activities, oxygenation levels may vary and the same constant flow may not be suitable for all tasks. Studies in COPD patients suggest that an automatic oxygen titration, which adjusts the oxygen flow automatically according to a patient's blood oxygen levels to prevent desaturations, could be beneficial compared to a constant oxygen titration during exercise. So far there are no studies available that directly compare the automatic oxygen titration with the patient's prescribed constant oxygen flow in patients with hypoxemia after SARS-CoV-2 infection during activities of daily life. Therefore, the primary outcome of this study is to investigate the effects of an automatic oxygen titration (O2matic, Denmark) in comparison to constant oxygen flow rates as prescribed according to guidelines.

Detailed description

Rationale After an infection with SARS-CoV-2, some patients still experience hypoxemia even after being discharged from the hospital. Long-term oxygen therapy (LTOT) is then used to increase the patients blood oxygen level and prolong the time spent within the SpO2 target range, decreasing the probability of severe hypoxemia or at least lowering the time spent in this severe hypoxemia and all in all enhance the patient's endurance. A prescription for LTOT is usually given for constant flow rates which might vary during day- and night use. This study is a randomized, controlled cross-over trial. Its aim is to investigate the effects of an automatic oxygen titration in patients after SARS-CoV-2 infection on the blood oxygen saturation level during activities of daily life (walking). Secondary, the effects of using an automatic titration on endurance, pCO2 blood level as well as heart rate and breathing frequency are compared to using the prescribed constant flow oxygen therapy. Design: Each patient undergoes a series of shuttle walk tests. After an initial incremental shuttle walk test (ISWT) to determine the patient's maximum walking speed, the patient undergoes 2 endurance shuttle walk tests (ESWTs) at 85% of the maximum walking speed. One of these ESWTs is performed with the prescribed constant oxygen flow, the other with the O2matic automatic oxygen titration in a random order. In addition to the shuttle walk tests, patient will perform two stair walking tests, again one with the prescribed constant oxygen flow, the other with the O2matic automatic oxygen titration in a random order. Furthermore, patients will be asked to rate their experienced comfort after each ESWT and to name their preferred oxygen titration system.

Interventions

OTHEROxygen therapy

Oxygen therapy during ESWTs and Stair Walking Test: one test using the prescribed constant oxygen flow and one using an automatic oxygen titration system. SpO2 target range: 90 - 94%

Sponsors

Schön Klinik Berchtesgadener Land
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* validated COVID19 disease in case history * hypoxemia (PO2 \< 55 mmHg) under room air conditions (rest or during exercise) or SpO2 \<88% during exercise * already established Long-term oxygen therapy or given indication for a Long-term oxygen therapy

Exclusion criteria

* acute infection * cardiovascular diseases that limit physical fitness * orthopedic diseases preventing the patient from undergoing the walking tests

Design outcomes

Primary

MeasureTime frameDescription
Change of oxygen saturation during the endurance shuttle walk TestsDay 2, 3SpO2 measured by continuous transcutaneous recording via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland)

Secondary

MeasureTime frameDescription
Change of heart rate during ESWTs and stair walking testsDay 2, 3, 4Heart rate measured by continuous transcutaneous recording via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland)
Change of respiratory rate during ESWTsDay 2, 3Respiratory rate measured by ApneaLink Air™
Change of time to desaturation (SpO2 ≤ 90%) and to severe desaturation (SpO2 ≤ 85%) during ESWTs and Stair Walking TestsDay 2, 3, 4SpO2 measured by continuous transcutaneous recording via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland) and O2matic Device.
Change of Endurance time (s)Day 2, 3, 4Change of Walking Duration during the ESWT and Stair Walking Tests
Change of transcutaneous pCO2 during ESWTsDay 2, 3tc pCO2 measured by continuous transcutaneous recording via Sentec-Digital Monitor® (Sentec, Therwil, Switzerland)
Change of capillary partial pressure of O2 (pO2) during endurance shuttle walk testsDay 2,3pO2 measured by capillary blood gases taken before and after the ESWT
Patients preference due to oxygen delivery systemDay 3Patients will be asked to rate their experienced comfort after each ESWT
Change of number of stairsDay 4Change of the number of stairs the patient was able to climb during Stair Walking Tests
Change of capillary partial pressure of CO2 (pCO2) during endurance shuttle walk testsDay 2, 3pCO2 measured by capillary blood gases taken before and after the ESWT

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026