Skip to content

Hearing Aid Signal Processing Comparative Study

A Study to Compare Patient Perceptions of Two Different Hearing Aid Signal Processing Philosophies

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04839289
Enrollment
27
Registered
2021-04-09
Start date
2021-07-01
Completion date
2021-08-31
Last updated
2023-03-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hearing Loss, Sensorineural

Brief summary

Participants will be fit with each of two hearing instruments in an ABA cross-over design. The study will consist of a total of three approximately 10-day home trials with the devices. Participants will be asked to provide qualitative feedback to investigators regarding the performance of and their preference for each hearing instrument.

Interventions

DEVICEReceiver-in-canal hearing instrument; Manufacturer A

Commercially available receiver-in-canal hearing instrument from manufacturer A

DEVICEReceiver-in-canal hearing instrument; Manufacturer B

Commercially available receiver-in-canal hearing instrument from manufacturer B

Sponsors

Sonova AG
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Masking description

Identifying information will be removed from the hearing instruments before fitting the participants. However, participants may be able to research hearing instruments and identify devices based on physical appearance.

Eligibility

Sex/Gender
ALL
Age
18 Years to 100 Years
Healthy volunteers
Yes

Inclusion criteria

* Moderate to severe sensorineural hearing loss * Current hearing aid user

Exclusion criteria

* Lack of willingness to wear study devices for approximately one month * Inability to travel to study appointments or to complete questionnaires.

Design outcomes

Primary

MeasureTime frameDescription
Standardized Validated Questionnaire Measuring Hearing Aid Sound Quality for First Study Set Worn, i.e. Study Set A for Arm A-B-A and Study Set B for Arm B-A-BEnd of home trial 1 (Day 10 of study)Qualitative feedback questionnaire to gather feedback on particular areas of focus. Subjects will rate hearing performance and sound quality on a Likert scale with lowest number equivalent to worst performance or worst sound quality (1) and higher number equivalent to best performance or best sound quality (10).
Standardized Validated Questionnaire Measuring Hearing Aid Sound Quality for Second Study Set Worn, i.e. Study Set B for Arm A-B-A and Study Set A for Arm B-A-BEnd of home trial 2 (20 days after study start)Qualitative feedback questionnaire to gather feedback on particular areas of focus. Subjects will rate hearing performance and sound quality on a Likert scale with lowest number equivalent to worst performance or worst sound quality (1) and higher number equivalent to best performance or best sound quality (10).
Standardized Validated Questionnaire Measuring Hearing Aid Sound Quality for Third Study Set Worn, i.e. Study Set A for Arm A-B-A and Study Set B for Arm B-A-BEnd of home trial 3 (30 days after study start)Qualitative feedback questionnaire to gather feedback on particular areas of focus. Subjects will rate hearing performance and sound quality on a Likert scale with lowest number equivalent to worst performance or worst sound quality (1) and higher number equivalent to best performance or best sound quality (10).
Standard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for First Study Set Worn.End of home trial 1 (Day 10 of study)Measures satisfaction on various aspects of hearing aid use on a scale from 1 to 5, with 1 = Very unsatisfied to 5 = Very satisfied, and 3 = Neutral. .
Standard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for Second Study Set Worn.End of home trial 2 (Day 20 of study)Measures satisfaction on various aspects of hearing aid use on a scale from 1 to 5, with 1 = Very unsatisfied to 5 = Very satisfied, and 3 = Neutral.
Standard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for Third Study Set Worn.End of home trial 3 (Day 30 of study)Measures satisfaction on various aspects of hearing aid use on a scale from 1 to 5, with 1 = Very unsatisfied to 5 = Very satisfied, and 3 = Neutral.

Countries

United States

Participant flow

Participants by arm

ArmCount
A-B-A
Participants will be fit with hearing instruments A and B in the following order: Hearing instrument A Hearing instrument B Hearing instrument A Receiver-in-canal hearing instrument; Manufacturer A: Commercially available receiver-in-canal hearing instrument from manufacturer A Receiver-in-canal hearing instrument; Manufacturer B: Commercially available receiver-in-canal hearing instrument from manufacturer B
17
B-A-B
Participants will be fit with hearing instruments A and B in the following order: Hearing instrument B Hearing instrument A Hearing instrument B Receiver-in-canal hearing instrument; Manufacturer A: Commercially available receiver-in-canal hearing instrument from manufacturer A Receiver-in-canal hearing instrument; Manufacturer B: Commercially available receiver-in-canal hearing instrument from manufacturer B
9
Total26

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyWithdrawal by Subject10

Baseline characteristics

CharacteristicA-B-AB-A-BTotal
Age, Continuous73.5 years67 years70.25 years
Mild to moderate severe sensorineural hearing loss, bilaterally17 participants9 participants26 participants
Race and Ethnicity Not Collected0 Participants
Region of Enrollment
China
0 participants9 participants9 participants
Region of Enrollment
United States
17 participants0 participants17 participants
Sex: Female, Male
Female
8 Participants6 Participants14 Participants
Sex: Female, Male
Male
9 Participants3 Participants12 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 270 / 27
other
Total, other adverse events
0 / 270 / 27
serious
Total, serious adverse events
0 / 270 / 27

Outcome results

Primary

Standardized Validated Questionnaire Measuring Hearing Aid Sound Quality for First Study Set Worn, i.e. Study Set A for Arm A-B-A and Study Set B for Arm B-A-B

Qualitative feedback questionnaire to gather feedback on particular areas of focus. Subjects will rate hearing performance and sound quality on a Likert scale with lowest number equivalent to worst performance or worst sound quality (1) and higher number equivalent to best performance or best sound quality (10).

Time frame: End of home trial 1 (Day 10 of study)

Population: Participants who were fit with first set of hearing aids for first home trial. For arm A-B-A, the outcomes will measure hearing aid A, and for arm B-A-B, the outcomes will measure hearing aid B

ArmMeasureValue (MEAN)Dispersion
A-B-AStandardized Validated Questionnaire Measuring Hearing Aid Sound Quality for First Study Set Worn, i.e. Study Set A for Arm A-B-A and Study Set B for Arm B-A-B7.16 score on a scaleStandard Deviation 0.46
B-A-BStandardized Validated Questionnaire Measuring Hearing Aid Sound Quality for First Study Set Worn, i.e. Study Set A for Arm A-B-A and Study Set B for Arm B-A-B7.12 score on a scaleStandard Deviation 0.85
Primary

Standardized Validated Questionnaire Measuring Hearing Aid Sound Quality for Second Study Set Worn, i.e. Study Set B for Arm A-B-A and Study Set A for Arm B-A-B

Qualitative feedback questionnaire to gather feedback on particular areas of focus. Subjects will rate hearing performance and sound quality on a Likert scale with lowest number equivalent to worst performance or worst sound quality (1) and higher number equivalent to best performance or best sound quality (10).

Time frame: End of home trial 2 (20 days after study start)

Population: Participants who were fit with second set of hearing aids for second home trial. For arm A-B-A, the outcomes will measure hearing aid B, and for arm B-A-B, the outcomes will measure hearing aid A

ArmMeasureValue (MEAN)Dispersion
A-B-AStandardized Validated Questionnaire Measuring Hearing Aid Sound Quality for Second Study Set Worn, i.e. Study Set B for Arm A-B-A and Study Set A for Arm B-A-B7.61 score on a scaleStandard Deviation 0.42
B-A-BStandardized Validated Questionnaire Measuring Hearing Aid Sound Quality for Second Study Set Worn, i.e. Study Set B for Arm A-B-A and Study Set A for Arm B-A-B6.70 score on a scaleStandard Deviation 0.98
Primary

Standardized Validated Questionnaire Measuring Hearing Aid Sound Quality for Third Study Set Worn, i.e. Study Set A for Arm A-B-A and Study Set B for Arm B-A-B

Qualitative feedback questionnaire to gather feedback on particular areas of focus. Subjects will rate hearing performance and sound quality on a Likert scale with lowest number equivalent to worst performance or worst sound quality (1) and higher number equivalent to best performance or best sound quality (10).

Time frame: End of home trial 3 (30 days after study start)

Population: Participants who were fit with third set of hearing aids for third home trial. For arm A-B-A, the outcomes will measure hearing aid A, and for arm B-A-B, the outcomes will measure hearing aid B

ArmMeasureValue (MEAN)Dispersion
A-B-AStandardized Validated Questionnaire Measuring Hearing Aid Sound Quality for Third Study Set Worn, i.e. Study Set A for Arm A-B-A and Study Set B for Arm B-A-B7.28 score on a scaleStandard Deviation 0.51
B-A-BStandardized Validated Questionnaire Measuring Hearing Aid Sound Quality for Third Study Set Worn, i.e. Study Set A for Arm A-B-A and Study Set B for Arm B-A-B7.52 score on a scaleStandard Deviation 0.95
Comparison: Null hypothesis: Subjective ratings of sound quality would not be different between any of the three study hearing aids when measured with a validated sound quality questionnaire.~Analysis was done after all three home trials completed so all three sets of study devices could be compared.p-value: >0.05t-test, 2 sided
Comparison: Null hypothesis: Subjective ratings of sound quality would not be different between any of the three study hearing aids when measured with a validated sound quality questionnaire.~Analysis was done after all three home trials completed so all three sets of study devices could be compared.p-value: <0.0167t-test, 2 sided
Primary

Standard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for First Study Set Worn.

Measures satisfaction on various aspects of hearing aid use on a scale from 1 to 5, with 1 = Very unsatisfied to 5 = Very satisfied, and 3 = Neutral. .

Time frame: End of home trial 1 (Day 10 of study)

Population: Participants who were fit with first set of hearing aids for first home trial. For arm A-B-A, the outcomes will measure study set A, and for arm B-A-B, the outcomes will measure study set B.

ArmMeasureValue (MEAN)Dispersion
A-B-AStandard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for First Study Set Worn.3.94 score on a scaleStandard Deviation 0.59
B-A-BStandard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for First Study Set Worn.3.80 score on a scaleStandard Deviation 0.3
Primary

Standard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for Second Study Set Worn.

Measures satisfaction on various aspects of hearing aid use on a scale from 1 to 5, with 1 = Very unsatisfied to 5 = Very satisfied, and 3 = Neutral.

Time frame: End of home trial 2 (Day 20 of study)

Population: Participants who were fit with second set of hearing aids for second home trial. For arm A-B-A, the outcomes will measure study set B, and for arm B-A-B, the outcomes will measure study set A.

ArmMeasureValue (MEAN)Dispersion
A-B-AStandard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for Second Study Set Worn.4.24 score on a scaleStandard Deviation 0.54
B-A-BStandard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for Second Study Set Worn.3.76 score on a scaleStandard Deviation 0.28
Primary

Standard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for Third Study Set Worn.

Measures satisfaction on various aspects of hearing aid use on a scale from 1 to 5, with 1 = Very unsatisfied to 5 = Very satisfied, and 3 = Neutral.

Time frame: End of home trial 3 (Day 30 of study)

Population: Participants who were fit with third set of hearing aids for third home trial. For arm A-B-A, the outcomes will measure study set A, and for arm B-A-B, the outcomes will measure study set B.

ArmMeasureValue (MEAN)Dispersion
A-B-AStandard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for Third Study Set Worn.4.12 score on a scaleStandard Deviation 0.47
B-A-BStandard Validated Questionnaire Measuring Satisfaction of Hearing Aid Performance and Features for Third Study Set Worn.3.99 score on a scaleStandard Deviation 0.21
Comparison: Null hypothesis: Satisfaction with hearing aid performance and features would not be different between any of the three study hearing aids when measured with subjective hearing aid satisfaction questionnaire.~Analysis was done after all three home trials completed so all three sets of study devices could be compared.p-value: <0.01666667t-test, 2 sided
Comparison: Null hypothesis: Satisfaction with hearing aid performance and features would not be different between any of the three study hearing aids when measured with subjective hearing aid satisfaction questionnaire.~Analysis was done after all three home trials completed so all three sets of study devices could be compared.p-value: <0.01666667t-test, 2 sided

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026