Assessment of Knee Flexor Muscles Strength in Patients With Patellar Instability

Assessment of Knee Flexor Muscles Strength in Patients With Patellar Instability and Its Clinical Implication in Non-surgical Treatment of Patients After First Patella Dislocation.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04838158
Enrollment
51
Registered
2021-04-08
Start date
2015-01-10
Completion date
2016-01-30
Last updated
2021-04-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Children, Only, Patella Dislocation Recurrent

Brief summary

The study enrolled 33 patients with confirmed recurrent patellar dislocation, including 6 patients with bilateral involvement. In the study group, both side hamstring muscle were evaluated at the velocities of 60 and 180 deg/s for the following parameters: peak torque, torque in 30 degree of the knee flexion, angle of peak torque and peak torque hamstring to quadriceps ratio (H/Q ratio).

Detailed description

The study enrolled 33 patients with confirmed recurrent patellar dislocation, including 6 patients with bilateral involvement. The study group consisted of 20 girls and 13 boys with average age at the time of the study 16.2 years (range: 8 to 17 years, SD 2.7). For the purpose of the study, a control group of 18 healthy subjects (12 girls and 6 boys) aged on the average 15.7 years (range:13 to 17 years, SD 1.5), was recruited. The following study inclusion criteria were applied: recurrent patellar dislocation, correctly completed testing protocol, age under 18 years at the time of testing. Subjects with osteochondral fracture and those with a history of the knee surgery were excluded. Each patient underwent an isokinetic examination on Biodex System 3 (Biodex Multi-Joint System - Pro, Biodex Medical Systems, Inc. New York, USA). In the study group, both side hamstring muscle were evaluated at the velocities of 60 and180 deg/s for the following parameters: peak torque (PT), torque in 30 degree of the knee flexion (T 30 deg.), angle of peak torque (APT) and peak torque hamstring to quadriceps ratio (H/Q ratio). Isokinetic measurements were made by a trained, experienced physiotherapist. After a proper warm-up and instruction, the test performed 10 full repetitions, the best result was recorded. The results of the peak torque (PT) of both test and control limbs were then compared with the normative data for age and gender available in the literature. In addition, we compared the peak torque (PT), torque in 30 degrees of the knee flexion (T 30 deg.), angle of peak torque (APT) and peak torque hamstring to quadriceps ratio (H/Q ratio) of involved and uninvolved knee flexor strength in the study group. Depending on the data distribution, the nonparametric Wilcoxon's test or the parametric t-test for the related data was applied. Statistical significance was assumed for p\<0.05. The study was approved by our Institutional Review Board. Informed consent was obtained and the rights of subjects were protected.

Interventions

DIAGNOSTIC_TESTIsokinetic measurements

Each patient underwent an isokinetic examination on Biodex System 3 (Biodex Multi-Joint System - Pro, Biodex Medical Systems, Inc. New York, USA). In the study group, both side hamstring muscle were evaluated at the velocities of 60 and180 deg/s for the following parameters: peak torque (PT), torque in 30 degree of the knee flexion (T 30 deg.), angle of peak torque (APT) and peak torque hamstring to quadriceps ratio (H/Q ratio).

Sponsors

Polish Mother Memorial Hospital Research Institute
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
8 Years to 17 Years
Healthy volunteers
Yes

Inclusion criteria

* recurrent patellar dislocation, * correctly completed testing protocol, * age under 18 years at the time of testing

Exclusion criteria

* osteochondral fracture * those with a history of the knee surgery

Design outcomes

Primary

MeasureTime frameDescription
hamstrings peak torqueup to 18 monthsmeasured on Biodex System
torque in 30 degrees of the knee flexionup to 18 monthsmeasured on Biodex System
angle of peak torqueup to 18 monthsmeasured on Biodex System
peak torque hamstring to quadriceps ratio (H/Q ratio)up to 18 monthsmeasured on Biodex System