Skip to content

PrizValve® Transcatheter Aortic Valve Replacement Study

Evaluation of the Efficacy and Safety of the Transcatheter Aortic Valve Replacement System in Patients With Severe Aortic Valve Stenosis Disease at High Surgical Risk

Status
Active, not recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT04836897
Enrollment
120
Registered
2021-04-08
Start date
2021-01-19
Completion date
2028-06-30
Last updated
2023-11-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Valve Stenosis

Brief summary

The purpose of this clinical study is to evaluate the effectiveness and safety of the transcatheter aortic valve system in the treatment of patients with severe aortic stenosis who are at high risk of surgery or who are not suitable for surgery.

Detailed description

This study is an multicenter, single-arm, prospective, safety and performance clinical study.

Interventions

DEVICEPrizValve® valve and transapical delivery system

Transcatheter aortic valve replacement system

Sponsors

Shanghai NewMed Medical Co., Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
65 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age ≥ 65 years ; 2. Patients with symptomatic severe aortic valve stenosis (evaluated by echocardiography: transaortic valve pressure gradient ≥40mmHg (1mmHg=0.133kPa), or transaortic valve blood flow rate ≥4m/s, or aortic Valve area\<1.0cm2, or AVA \<0.5cm2 /m2); 3. NYHA ≥ II; 4. Life expectancy\> 12 months; 5. Patients who are anatomically suitable for transcatheter aortic valve implantation; 6. After evaluation by two or more cardiovascular surgeons, patients who are unsuitable for surgery; or patients who refuse surgery after sufficient communication by the surgeons and are at high risk of routine surgery; 7. Patients who can understand the purpose of the trial, voluntarily participate in and signed informed consent form, and are willing to accept relevant examinations and clinical follow-ups.

Exclusion criteria

1. Acute myocardial infarction occurred within 1 month before this treatment; 2. Congenital single leaf aortic valve; 3. Any therapeutic cardiac operation (including placement of coronary drug-eluting stents) within 30 days; 4. The patient's heart has been implanted with other artificial heart valves, artificial rings, or severe mitral regurgitation (\>3+); 5. Blood system diseases or abnormalities, including leukopenia (WBC\<3×109/L), acute anemia (HB \<90g/L), thrombocytopenia (PLT\<50×109/L), bleeding constitution and coagulopathy ; 6. Untreated severe coronary artery stenosis that requires revascularization; 7. Patients with hemodynamic or respiratory instability, requiring continuous mechanical heart assistance or mechanical ventilation; 8. Patients who need emergency surgery for any reason; 9. Hypertrophic cardiomyopathy with obstruction; 10. Severe left ventricular dysfunction, left ventricular ejection fraction (LVEF) \<20%; 11. The echocardiogram indicates the presence of a heart mass, thrombus or vegetation; 12. A history of acute peptic ulcer or upper gastrointestinal bleeding within 3 months; 13. Are allergic to cobalt-chromium alloys or contrast agents, and cannot tolerate anticoagulation and antiplatelet therapy; 14. The diameter of the aortic valve annulus \<16mm or \>28mm; 15. In any case, patients who refuse surgical treatment in emergency situations; 16. Cerebrovascular accident occurred within 3 months, not including transient ischemic attack; 17. Severe aortic diseases, including abdominal aortic or thoracic aortic aneurysm, obvious curvature of the aortic arch, atherosclerosis of the aortic arch, narrowing of the abdominal or thoracic aorta, and obvious curvature or extension of the thoracic aorta; 18. The iliac-femoral artery is severely obstructed with calcification, severely tortuous or unable to place the 1418F catheter sheath kit; 19. Active infective endocarditis or other active infections; 20. Aortic valve leaflets calcified plaque close to the coronary ostium; 21. Severe disability Alzheimer's disease and unable to take care of oneself in life; 22. Those who have participated in clinical trials of other drugs or medical devices before entering the group and have not yet reached the time limit of the primary research endpoint; 23. The researcher judged that the patient had poor compliance and could not complete the study as required.

Design outcomes

Primary

MeasureTime frameDescription
Freedom from all-cause mortality12 monthsAll-cause mortality within 12 months of TAVI procedure

Secondary

MeasureTime frameDescription
Device successimmediate post-surgicalDevice success after TAVI
Procedural successimmediate post-surgicalProcedural success after TAVI
Freedom from all-cause mortality2-5 yearsAll-cause mortality within 2-5 years of TAVI procedure
Rate of All disabling stroke30 days、6 months、1-5 yearsRate of All disabling stroke after TAVI
Rate of Severe bleeding30 days、6 months、1-5 yearsRate of Severe bleeding after TAVI
Rate of Myocardial infarction30 days、6 months、1-5 yearsRate of Myocardial infarction after TAVI

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026